Thermo Electron Corporation TSC-46 Analyzer
Производитель:
Модель:
TSC-46
Дата:
1990
Категория:
Группа:
Описание:
Thermocouple Simulator

Информация

General Resistance Thermocouple Simulators (ETS/TSC) are versatile laboratory instruments that provide high precision and stability in compact portable units. They are designed and constructed as to be essentially independent of the ambient temperature and loading within their ratings. Each has the following basic functional modules: 1. A chopper-stability operational Amplifier. 2. A highly stable reference source. 3. A Kelvin-Varley potential divider. 4. A cold junction compensator (CJC) for each of 5 separate thermocouple systems. 5. Connection facilities for any thermocouple type. These precision instruments are not to be confused with low-cost hand-held “do-everything” devices. The TSC/ ETS line of T/C Simulators provides “standards lab performance.” TSC/ETS units provide ±1/4% accuracy and can be used to calibrate virtually any T/C system at any temperature with internal cold function compensation referenced to 0°C. Potentiometers and ice baths are not required. These GR instruments, moreover, provide “zero output impedance,” an exclusive feature available with no other simulator. “Zero output Z” insures that the system element (readout device, scanner or whatever) under test or calibration will respond only to the simulated temperature signal supplied by the General Resistance TSC or ETS. This eliminates the need to disconnect the system thermocouple. In addition to its TSC/ETS line of ultra-precision instruments, General Resistance offers its Model E-35B Instant Lab for use as a T/C simulator. Model E-35B is unmatched for multi-usage versatility. It performs as a thermocouple and RTD simulator, current/voltage source and resistance decade box ... all with ±0.1% accuracy. (See Table I and back cover for further details on E-35B.) MODELS AVAILABLE Model TSC-47UR — The finest and most versatile instrument of its type available anywhere outside of a primary standards laboratory. Designed for use as a portable standard and as a constant voltage/current source as well as thermocouple simulator. Model TSC-46 — Similar to the TSC-47UR with 6 rather than 7 decade KVD. See Table I Specifications for specific differences between these two models. Model ETS-15 — Same accuracy and “Zero output Z” performance as TSC Series relative to T/C simulation. Differs from TSC units in that it is truly portable with internal batteries. It also provides built-in run-up pot, control circuit and temperature measurement capability. Does not offer 10V F.S. Voltage Source performance. Model E-35B —see back page. THERMOCOUPLE SIMULATION: These instruments simulate all thermocouple types —E, J, K, R, S, T, B, N, etc. —internally referenced-junction -compensated to 0°C. Connection to the thermocouple system to be tested is through the use of specially designed THERMOCLIPS1* (see Table II). Output is dialed in voltage on thumbwheel-decade switches. Any reference tables can be used — DIN, NBS, etc. BATTERY OPERATION (ETS-15 E-35B): Instrument will operate for approximately 8 hours on a full charge under normal conditions and recharge within 10 hours. Units are fully operative during the charge cycle. Trickle charging takes place as long as unit is plugged in, whether it is turned ON or OFF. OPERATION: Five basic operating modes are as follows: 1. Thermocouple simulation with zero output impedance. Appropriate Thermoclips (See Table II) are clipped into the system. Since output impedance is “zero” there is no need to disrupt system wiring. After temperature-equivalent voltage is dialed, this known signal is used to calibrate or troubleshoot scanners, linearizers or readouts. 2. Thermocouple simulation with output impedance established by front panel “run-up" pot. (AVAILABLE WITH MODEL ETS-15 ONLY.) Built-in runup pot is set to the system Impedance. Thermoclips are used to substitute the simulated output for the active thermocouple. The “run-up” pot is used to simulate the system’s wiring in order to calibrate loop-impedance-dependent analog readout devices. 3. Temperature measurements. The Simulator is connected to the active measuring thermocouple with the appropriate Thermoclips. The thumbwheel switches are adjusted until a null Is indicated on a built-in meter which is designed for logarithmic response. (External null detector required for Models TSC-46 TSC-47UR E-35.) 4. Control mode. (AVAILABLE WITH MODEL ETS-15 ONLY.) Appropriate Thermoclips are connected. Any voltage differences between that set on the Simulator dials and that produced by the system thermocouple is detected and amplified by a fixed gain of 25. This "error signal” appears at the CONTROL terminals and provides external control circuitry with the analog information required to correct temperature, activate alarms, etc. 5. High accuracy voltage/current source. (AVAILABLE WITH MODELS TSC-46 and TSC-47UR ONLY.) These sophisticated instruments provide all of the precision performance characteristics of GR's time-tested DAS voltage/current sources in addition to serving as thermocouple simulators.

показать больше

Обслуживание и Руководство пользователя
Hасто́льная кни́га тип:
Обслуживание и Руководство пользователя
Страницы:
34
Размер:
1.57 Mbytes (1646834 Bytes)
Язык:
english
Пересмотр:
Hасто́льная кни́га ID:
Дата:
1990 01 01
Качество:
Отсканированы документу, все читается.
Дата загрузки:
2020 01 11
MD5:
53d43217135e8da0e83729d63fb32b2d
Загрузчик:
Armin
Загрузки:
936

Информация

2, 3 Table of Contents 4 List of Illustrations 5 Limited Warranty 1.0 7 Introduction & Description 1.1 7,8 General 1.2 11,12 Specification Sheet 2.0 13 Initial Set-Up 2.1 13 Unpacking & Inspection 2.2 13 Output Cables 2.3 14 t Output Connector 3.0 17 Operating Instructions (TSC Series) 3.1 17 Operating Controls 3.2 18, 19 Operation as a Thermocouple Simulator 3.3 19 Operation as a Voltage/ Current Reference Source 4.0 20 Operating Instructions (ETStI 5) 4.1 20 Operating Controls 4.2 22 Operation: Zero Ohms Thermocouple Simulation Mode Operation: Run-Up Ohms Thermocouple Simulation Mode Operation: Measure Mode Operation: Control Mode Battery Operation Repair and Maintenance Repair Maintenance Amplifier Zero Set (TSC Series) Amplifier Zero Set (ETS-15, Reference Source Calibration (TSC Series) Reference Source Calibration (ETS-15, Optional Accessories TSC used as a Voltage/Current Source A 6 Photographs (ETS & TSC) B 9 Systems Block Diagram C 10 Output Cable & Connector D 15 Front Panel Controls (TSC-46, E 16 Front Panel Controls (TSC-47UR, F 21 Front Panel Controls (ETS-15,

показать больше