Telecommunications Techniques Corporation Fireberd 4000 Анализатор сети
Manufacturer:

Image 1 of 1
If you have any other photos or manuals for the
Telecommunications Techniques Corporation Fireberd 4000 you can upload the files here .
Model:
Fireberd 4000
Date:
1991
Category:
Group:
Description:
Information
The Fireberd 4000 (Figure 1-1) is an instrument that uses
internal and modular interfaces to test the quality of
digital communications networks and equipment. It provides
the analysis capabilities to isolate circuit malfunctions
and report the results on the front panel or on a printout.
Highly versatile, the Fireberd 4000 is used in locations
such as central offices, technical control centers, end-user
sites, engineering laboratories, and earth stations.
1.2.1 Features
The Fireberd 4000 offers these key features and characteristics:
• Operates on circuits transmitting and receiving data from
50 b/s to 15 Mb/s.
• Complete error analysis with bit, block, BPV, code,
character, and frame or CRC errors measured simultaneously.
• Set-up panel and display that permits configuration of the
unit for any test from the front-panel.
• Synchronous and asynchronous testing via internal EIA
RS-232-C and MIL-STD-188C interfaces.
• CCITT V.35, EIA RS-449, DDS, Tl, G.704, and G.703 testing
via modular interfaces installed in the FIREBERD 4000’s rear
panel.
• Thirteen fixed clock frequencies ranging from 300 Hz to
2048 kHz.
® Generates six fixed data patterns: MARK only, SPACE only,
1:1, 1:7, and 3IN24, 1004Hz.
® Generates seven pseudorandom data patterns: 63, 511, 2047,
2lM, 220-1, 223-l, and QRSS.
• Generates user-programmable patterns that include: a
synchronous 3- to 24-bit binary test pattern and three
asynchronous (three synchronous with Option 4006) 1- to
2000-character hexadecimal test patterns for acceptance
testing, stress testing, or simulating live data.
• Generates standard FOX message in four asynchronous (one
synchronous with Option 4006) character formats: Baudot,
BCDIC, ASCII, and EBCDIC.
• RS-232 printer/remote controller Interface provides access
for an external printer for printing test results and unit
configurations, or computer-controlled operation for
unattended testing from a remote site.
• Dual results displays which show any two test measurements
at the same time.
• Summary test results category that displays key nonzero
and “out-of-spec” measurements, eliminating the need to
search through long lists of test results.
• Histogram analysis displayed in either a graph or list
provides a perspective as to how selected results change
with time.
Manual type:
Руководство пользователя
Pages:
170
Size:
6.76 Mbytes (7084710 Bytes)
Language:
english
Revision:
B
Manual-ID:
ML11063
Date:
1991 02 01
Quality:
Отсканированы документу, все читается.
Upload date:
2017 01 09
MD5:
19a759543a91918b2f8f29011ccd83b2
Downloads:
854
Information
1.0 GENERAL
INFORMATION ... 1-1
1.1
INTRODUCTION ... 1-1
1.2 INSTRUMENT
OVERVIEW ... 1-1
1.3 OPERATING
MODES ... 1-3
2.0 PREPARATION FOR
USE ... 2-1
2.1
INTRODUCTION ... 2-1
2.2 UNPACKING AND INITIAL
INSPECTION ... 2-1
2.3 INSTRUMENT
IDENTIFICATION ... 2-1
2.4 EQUIPMENT
INCLUDED ... 2-1
2.5
WARNINGS ... 2-1
2.6 POWER
REQUIREMENTS ... 2-2
2.7 INSTRUMENT
CHECKOUT ... 2-4
3.0 INSTRUMENT
DESCRIPTION ... 3-1
3.1
INTRODUCTION ... 3-1
3.2 PHYSICAL
DESCRIPTION ... 3-1
3.3 FRONT PANEL CONTROLS AND
INDICATORS ... 3-1
3.4 Fireberd 4000 REAR PANEL
... 3-6
4.0 OPERATING
INSTRUCTIONS ... 4-1
4.1
INTRODUCTION ... 4-1
4.2 CONFIGURING THE FIREBERD 4000
... 4-1
4.3 STEPPING THROUGH THE SETUP
MENUS ... 4-1
4.4 Interface SETUP
CATEGORY ... 4-6
4.5 Generator CLOCK SETUP
CATEGORY ... 4-6
4.6 PATTERN SETUP
CATEGORY ... 4-12
4.7 SETUP SUMMARY
DISPLAY ... 4-19
4.8 RECALL/STORE
CATEGORY ... 4-19
4.9 AUXILIARY SETUP
CATEGORY ... 4-21
4.10 CONTENTION
CONDITIONS ... 4-28
4.11 OPERATING IN SELF LOOP
MODE ... 4-28
4.12 Fireberd 4000 ANALYSIS
RESULTS ... 4-29
5.0 DATA
INTERFACES ... 5-1
5.1
INTRODUCTION ... 5-1
5.2
OVERVIEW ... 5-1
5.3 INTERNAL RS-232 AND MIL188 DATA
INTERFACES ... 5-4
5.4 ISU-6000 Interface SWITCHING
UNIT ... 5-12
6.0 PRINTER
OPERATION ... 6-1
6.1
INTRODUCTION ... 6-1
6.2 GETTING
STARTED ... 6-1
6.3 PRINTER CONTROL
PANEL ... 6-1
6.4 AUXILIARY SETUP PRINTER
MENUS ... 6-2
6.5 THE PR-45 THERMAL
PRINTER ... 6-6
6.6 Fireberd 4000 PRINTER
INTERFACES ... 6-8
7.0 REMOTE
CONTROL ...
7-1
7.1
INTRODUCTION ...
7-1
7.2 RS-232-C REMOTE CONTROL
OPERATION ... 7-1
7.3 IEEE-488 REMOTE CONTROL
OPERATION ... 7-5
7.4 REMOTE CONTROL
COMMANDS ... 7-7
7.5 ENTERING LONG USER PATTERNS FROM A REMOTE DEVICE
... 7-12
8.0
SPECIFICATIONS ... 8-1
8.1
INTRODUCTION ... 8-1
8.2 OPERATING
MODES ... 8-1
8.3
GENERATOR ... 8-1
8.4
RECEIVER ... 8-2
8.5 PROGRAMMABILITY
... 8-3
8.6 NON-VOLATILE
MEMORY ... 8-4
8.7 REMOTE CONTROL
CAPABILITY ... 8-4
8.8 DATA
INTERFACES ... 8-4
8.9 REAL TIME
CLOCK ... 8-5
8.10
DISPLAY ... 8-5
8.11 AUDIO
OUTPUT ... 8-6
8.12 POWER
REQUIREMENTS ... 8-6
8.13 ENVIRONMENTAL
SPECIFICATIONS ... 8-6
8.14 DIMENSIONS AND
WEIGHT ... 8-6
9.0 OPTIONS AND Accessories
... 9-1
9.1
INTRODUCTION ... 9-1
9.2
OPTIONS ... 9-1
9.3
ACCESSORIES ... 9-1
10.0 MAINTENANCE AND SERVICE
... 10-1
10.1
INTRODUCTION ... 10-1
10.2
MAINTENANCE ... 10-1
10.3
SERVICE ... 10-3
APPENDICES
APPENDIX A HEXADECIMAL CONVERSION
TABLE ... A-1
APPENDIX B ANALYSIS RESULTS BY DATA
INTERFACE ... B-1
APPENDIX C ANALYSIS RESULTS
DEFINITION ... C-1
APPENDIX D MAINFRAME STATUS AND ERROR
MESSAGES ... D-1
APPENDIX E Fireberd 4000 FACTORY
DEFAULTS ... E-1
APPENDIX F OPTION 4004, CCITT G.821 PERFORMANCE
ANALYSIS
DISCUSSION ... F-1