Tektronix SD-20 Зонд
Производитель:
Модель:
SD-20
Дата:
1993
Категория:
Группа:
Описание:
Sampling Head

Информация

The SD-20 Sampling Head is a high-performance sampling head that can be installed in the 11800 Series Digital Sampling Oscilloscopes, the SM-11 Multi-Channel Unit, and the CSA 803 Series Communications Signal Analyzers. The SD-20 Sampling Head provides the following features: ■ A one-channel feed thru path for signal acquisition and measurements. ■ A 17.5 ps acquisition rise time. ■ A 20 GHz typical bandwidth for high-speed signal capture. ■ Displayed noise is 750 |jVRMs typical without smoothing and 350 |jVRMs typical with smoothing on. ■ Precision 3.5 mm connectors. ■ A SELECT CHANNEL button for quick trace acquisition and selection from the sampling head front panel. As shown in Figure 1, the SD-20 Sampling Head has a single acquisition channel with a feed thru or loop path (labeled LOOP on the front panel), an INPUT connector, and a FEED THRU connector (both of these connectors are also located on the front panel). The strobe drive signal from the instrument controls the timing of the strobe assertion to the Acquisition system.

показать больше

Руководство пользователя
Hасто́льная кни́га тип:
Руководство пользователя
Страницы:
52
Размер:
473.65 Kbytes (485019 Bytes)
Язык:
english
Пересмотр:
Hасто́льная кни́га ID:
070–7531–02
Дата:
1993 01 01
Качество:
Электронный документ, ни сканирование, очень хорошо читается.
Дата загрузки:
2017 12 27
MD5:
59e6b834dc7034882c13d52dbf093814
Загрузки:
436

Информация

List of Figures ... iii List of Tables ... v Introduction ... 1 Safety ... 3 Electrostatic Discharge ... 5 Connector Care ... 7 Installing the Sampling Head ... 9 Using the Sampling Head ... 11 Connecting Signals ... 12 Button and Light ... 13 Instrument/Sampling Head Interaction ... 14 Smoothing ... 14 External Attenuation ... 14 Displaying a Trace ... 16 Adjusting Parameters ... 19 Stored Parameters ... 20 Loop Gain ... 21 Adjusting Loop Gain ... 22 Offset Null ... 23 Adjusting Offset Null ... 23 Taking TDR Measurements ... 25 TDR Step Generator ... 25 Operation with a Short Circuit ... 26 Operation with a 50 Q Load ... 27 Operation with an Open Circuit ... 27 Baseline Correction ... 28 Example: Taking TDR Measurements ... 29 Changing Graticule Units for TDR ... 30 Other Triggering Configurations ... 33 External Generator with Pre-Trigger Out ... 33 External Free-Running Generator ... 34 Specifications ... 35 Glossary ... 37 Index ... 39

показать больше