Philips PM6302 LCR Meter
Производитель:
Модель:
PM6302
Дата:
1979
Категория:
Группа:
Описание:
RCL Bridge
Информация
The RCL-bridge PM 6302 is used to measure ohmic resistors in the range 0.05 £1... 105 Mfi, capacitors in the range 0.5 pF ... 1050 fxF and inductances in the range 0.5 /jH ... 1050 H. When measuring capacitors and inductances also a measuring value of the loss factor D or the quality factor Q is obtained. For the adjusting a vernier with linear indicator scale is used. The unknown measuring value is obtained after the adjusting by multiplying the scale value by the factor of the selected measuring range. The bridge balance is indicated by a moving-coil indicator, which is controlled by an Amplifier with logarithmic gain characteristic, adjusting of the bridge sensitivity being then redundant. Push-buuon SEARCH is used to find quickly the correct measuring range in the searching mode. For measuring electrolytic capacitors an external formation voltage can be supplied. By means of an external adjustable d.c.-voltage it is possible to measure junction-capacitances on varicaps.

показать больше

Обслуживание и Руководство пользователя
Hасто́льная кни́га тип:
Обслуживание и Руководство пользователя
Страницы:
57
Размер:
1.87 Mbytes (1963170 Bytes)
Язык:
english, german, french
Пересмотр:
Hасто́льная кни́га ID:
9499 52 05902
Дата:
01 Февраль 1979
Качество:
Сканированный документ, читая частично плохо, частично не читается.
Дата загрузки:
04 Февраль 2017
MD5:
9c4ed98a23e75eb57a556862990a955b
Загрузки:
351
Информация
1. GENERAL INFORMATION 7 1.1. Introduction 7 1.2. Technical data 7 1.3. Accessories 9 1.4. Description of the block diagram 10 2. DIRECTIONS FOR USE 10 2.1. Installation 10 2.1.1. Safety regulations 10 2.1.2. Controls and sockets 10 2.1.3. Position 11 2.1.4. Connection to the mains 11 2.1.5. Earthing 11 2.2. Operation 11 2.2.1. Switching on the instrument 11 2.2.2. Measuring resistors 11 2.2.3. Measuring capacitors 11 2.2.4. Measuring inductances 12 2.2.5. Measuring with external a.c. voltage supply 13 3. SERVICE DATA 31 3.1. Circuit description 31 3.1.1. Bridge arrangements 31 3.1.1.1 Bridge for R measurement 31 3.1.1.2 Bridge for C measurement 31 3.1.1.3 Bridge for L measurement 32 3.1.2. Zero indicator 32 3.1.2.1 A.c.-d.c. Converter 32 3.1.2.2 Operational Amplifier as a voltage-current inverter 33 3.1.3. Supply voltage Generator 33 3.1.3.1 D.C. voltage supply 33 3.1.3.2 Supply Oscillator 33 3.1.4. Arrangement for the searching range 33 3.1.5. Current supply 34 3.2. Gaining access to parts 34 3.3. Maintenance and service 34 3.4. Survey of adjusting elements and auxiliary equipment 35 3.5. Checking and adjusting 36 3.5.1. General test 36 3.5.2. Adjusting procedures 37 3.5.3. Testing the bridge functions 38 3.6. Parts list 42 3.6.1. Mechanical parts 42 3.6.2. Electrical parts 43