Kenwood CS-1012 Осциллограф
Manufacturer:

Image 1 of 2

Image 2 of 2
If you have any other photos or manuals for the
Kenwood CS-1012 you can upload the files here .
Model:
CS-1012
Date:
1991
Category:
Group:
Description:
Dual Trace Oscilloscope
Information
Vertical axis has high sensitivity and wide bandwidth and especially covers fully specified frequency response at 2mV/div for all models.
CS-1022, 1021 ;
Dual Trace
1 mV/div : DC to 10 MHz, -3 dB 2mV/div : DC to 20 MHz, -3 dB
CS-1012 ; Dual Trace
1 mV/div : DC to 7 MHz, -3 dB 2mV/div : DC to 10 MHz, -3 dB
CS-1020 ; Single Trace
1 mV/div : DC to 10 MHz, -3 dB 2mV/div : DC to 20 MHz, -3 dB
CS-1010 ; Single Trace
1 mV/div : DC to 7 MHz, -3 dB 2mV/div : DC to 10 MHz, -3 dB
• Vertical sensitivity range is selectable from 1 mV/div to 5V/div with rotary switch continuously.
• Time base permits the high sweep speed.
CS-1022, 1020; 20nsec/div (x10 MAG)
CS-1021, 1012, 1010; 50nsec/div (x10 MAG)
• Vertical sensitivity error and sweep rate error are ±3% and accurate measurements are provided.
• The 150 mm rectangular CRT with internal graticule provides high brightness and accurate measurements, free of parallax error.
CS-1022, 1020; domed mesh type CRT with post deflection acceleration and high brightness phosphors (acceleration voltage; 6 kV).
CS-1021, 1012, 1010; high brightness CRT (acceleration voltage; 2 kV).
• For convenience in making rise time measurements, the 0%, 10%, 90% and 100% levels are marked on the graticule scale of the CRT.
• Trace rotation is electrically adjustable from the front panel.
• By SCALE ILLUM control, the waveform is easy observed in the dark and the photograph of the waveform is easy provided. (Except(CS-1021)
• Selectable AUTO FREE RUN function provides sweep without trigger input signal.
• The FRAME-LINE switch provides selection of sync pulse for sweep triggering from small amplitude to large amplitude without adjusting when viewing composite video waveforms.
• For CS-1022
1021 and 1012, vertical mode automatically provides the trigger signal with TRIG SOURCE and V. MODE switches.
• X-Y operation is easy provided by one-touche.
CS-1022, 1021, 1012; CH1 Y axis,
CH2 X axis CS-1020
1010; VERT INPUT Y axis
EXT TRIG INPUT X axis
• CS-1022 and 1012 are provided with CH1 OUTPUT terminal to monitor input signal of CH1.
• CS-1020 and 1010 are provided with VERT OUTPUT terminal to monitor input signal of VERT INPUT.
Manual type:
Руководство по техническому обслуживанию
Pages:
87
Size:
11.90 Mbytes (12476526 Bytes)
Language:
english
Revision:
Manual-ID:
Date:
Quality:
Отсканированы документу, все читается.
Upload date:
28 December 2020
MD5:
1103c56c96103dcdcd3c9fafffac145b
Downloads:
2627
Information
SPECIFICATIONS ... 2
SAFETY ... 6
CIRCUIT DESCRIPTION ... 7, 9
BLOCK DIAGRAM ... 8, 10
ADJUSTMENT ... 11
TROUBLESHOOTING ... 15
PARTS LIST ... 17
SEMICONDUCTORS ... 38
DISASSEMBLY ... 39
P.C. BOARD ... 40
SCHEMATIC DIAGRAM ... 41
Manual type:
Руководство по техническому обслуживанию
Pages:
55
Size:
21.56 Mbytes (22610503 Bytes)
Language:
english
Revision:
Manual-ID:
Date:
Quality:
Сканированный документ, читая частично плохо, частично не читается.
Upload date:
28 December 2020
MD5:
2d1f213f140e5270bf13823c7c21bba5
Uploader:
Guidopianino
Downloads:
2315
Information
SPECIFICATIONS ... 2
SAFETY ... 6
CIRCUIT DESCRIPTION ... 7, 9
BLOCK DIAGRAM ... 8, 10
ADJUSTMENT ... 11
TROUBLESHOOTING ... 15
PARTS LIST ... 17
SEMICONDUCTORS ... 38
DISASSEMBLY ... 39
P.C. BOARD ... 40
SCHEMATIC DIAGRAM ... 41
Manual type:
Руководство пользователя
Pages:
31
Size:
5.87 Mbytes (6160360 Bytes)
Language:
english
Revision:
Manual-ID:
B50-7570
Date:
01 December 1991
Quality:
Отсканированы документу, все читается.
Upload date:
17 May 2020
MD5:
75cc6fd66c3ed817f2e8277923300051
Uploader:
Fabio
Downloads:
2082
Information
SAFETY ...
FEATURES ...
SPECIFICATIONS ...
PREPARATION FOR USE ...
CONTROLS AND INDICATORS ...
FRONT PANEL ...
REAR PANEL ...
OPERATION ...
INITIAL STARTING PROCEDURE ...
(1) NORMAL SWEEP DISPLAY OPERATION ...
(2) MAGNIFIED SWEEP OPERATION ...
(3) X-Y OPERATION ...
(4) VIDEO SIGNAL OBSERVATION ...
APPLICATION ...
Probe COMPENSATION ...
TRACE ROTATION COMPENSATION ...
DC VOLTAGE MEASUREMENTS ...
MEASUREMENTS OF THE VOLTAGE
BETWEEN TWO POINTS ON A WAVEFORM ...
ELIMINATION OF UNDESIRED SIGNAL
COMPONENTS ...
TIME MEASUREMENTS ...
FREQUENCY MEASUREMENTS ...
PULSE WIDTH MEASUREMENTS ...
PULSE RISE TIME AND FALLTIME
MEASUREMENTS ...
TIME DIFFERENCE MEASUREMENTS ...
PHASE DIFFERENCE MEASUREMENTS ...
RELATIVE MEASUREMENTS ...
APPLICATION OF X-Y OPERATION ...
ACCESSORIES ...
Добавить комментарий
Правила пользования порталом
«Правила пользования порталом» содержат правила размещения комментариев на портале Cita Rīga. Добавляя свой комментарий, Вы подтверждаете, что согласны со следующим:
- Хотя модератор и будет пытаться проверить комментарии, невозможно оперативно проверить все добавленные комментарии.
- Все комментарии содержат мнения и суждения соответствующих авторов, но ни в коем случае не администратора или авторов портала Cita Rīga.
- Вы соглашаетесь не размещать в своих комментариях заведомо ложный, незаконный, содержащий угрозы, оскорбительный, порнографический материал, а также разжигающий ненависть или нарушающий частную жизнь других.
- Администратор сохраняет за собой право без предупреждения редактировать, перемещать или удалять любой комментарий, если он не соответствует данным Правилам пользования порталом.
Нарушение данных Правил может привести к лишению возможности добавления комментариев в дальнейшем.
Эти Правила могут измениться в любой момент и без предупреждения.
Комментарии