20MHz Oscilloscope

Информация

High Sensitivity Sensitivity as high as 1 mV/div. Wide Bands The frequency band is DC to 5 MHz (- 3 dB) at 1, 2 mV/div and DC to 20 MHz I DC to 40 MHz for CS-4035 1 (— 3 dB) from 5 mV/div. Continuous Switching Attenuator A rotary switch enables vertical axis sensitivity to be adjusted continuously from 1m V/div to 5 V/div. High Speed Sweep High speed sweeping is possible at a time base of 50 ns/div Iduring x 10 MAG) I 20 ns/div for CS-4035 and CS-4026 |. High Accuracy Accuracy within 3% for both vertical axis sensitivity and sweep time. Large Aperture The 150 mm rectangular CRT monitor features an internal graticule easy visual recognition of waveforms. The waveforms displayed in high brightness can be monitored with no parallax. Acceleration voltage: 12 kV for CS-4035 and CS-4026 2 kV for CS-4025 Trace Rotation The horizontal trace angle is easily corrected. Automatic Free Run The trace can be checked even when there are no trigger signals to be input, revision Trigger With a specially designed circuit, adjustment-free, stable synchronization for both frames and lines can be realized over the whole range from large to small amplitudes. One Touch X-Y Switching to X-Y operation at the touch of a lever switch. Automatic Trigger Signal Selection Trigger signals can be selected automatically according to the VERT MODE control setting by simply switching the SOURCE control to VERT. CH1 OUTPUT A channel 1 output terminal has been added for CH1 input signal monitoring. High Stability, High Reliability Hybrid integrated circuits have been employed in all the components, realizing high standards in terms of both stability and reliability. Prevention of Trace Line Jump When Selecting Input Signal Coupling Better operability has been achieved with an anti- trace line jump circuit that prevents sudden changes in the trace position when input signal coupling is switched from GND to AC position. Scale Illumination The scale illumination function makes it possible to take photographs of waveform data displayed on the CRT in a darkend room. | CS-4025 does not have this function )

показать больше

Руководство по техническому обслуживанию
Hасто́льная кни́га тип:
Руководство по техническому обслуживанию
Страницы:
36
Размер:
6.08 Mbytes (6371913 Bytes)
Язык:
english
Пересмотр:
Hасто́льная кни́га ID:
Дата:
Качество:
Отсканированы документу, все читается.
Дата загрузки:
2020 12 28
MD5:
60d5ddb19a6ff5489eed1820e2ea935a
Загрузки:
433

Информация

SPECIFICATIONS ... 3 SAFETY ... 6 CIRCUIT DESCRIPTION ... 7 BLOCK DIAGRAM ... 9 ADJUSTMENT ... 10 TROUBLESHOOTING ... 15 PARTS LIST ... 20 DISASSEMBLY ... 21 PARTS LIST (ELECTRICAL) ... 22 SCHEMATIC DIAGRAM/WAVEFORM ... 26 P.C. BOARD ... 31 SEMICONDUCTORS ... 33

показать больше

Руководство пользователя
Hасто́льная кни́га тип:
Руководство пользователя
Страницы:
31
Размер:
2.38 Mbytes (2495749 Bytes)
Язык:
english
Пересмотр:
Hасто́льная кни́га ID:
Дата:
Качество:
Отсканированы документу, все читается.
Дата загрузки:
2020 12 28
MD5:
b36334ffd2de10d4b51d400c060b49db
Загрузки:
834

Информация

SAFETY ... 2 SAFETY AND EQUIPMENT PROTECTION PRECAUTION ... 4 FEATURES ... 6 PANEL EXPLANATION ... 7 FRONT PANEL ... 7 REAR PANEL ... 12 CHECKING AND ADJUSTMENTS PRIOR TO MEASUREMENT ... 13 OPERATING PROCEDURES ... 15 SINGLE TRACE OPERATION ... 15 Alternating Current Display ... 15 Composite Video Signal Display ... 16 DUAL TRACE OPERATION ... 16 Switching Vertical Operation Modes ... 16 Switching Trigger Source ... 16 External Trigger ... 16 Line Trigger ... 17 SWEEP MAGNIFIED OPERATION ... 17 X-Y OPERATION ... 17 APPLICATIONS ... 18 Measuring Voltage Between Two Points on a Waveform ... 18 Common-Mode Rejection ... 19 Measuring Direct Current (DC) Voltage ... 20 Measuring Signals with Low Frequency Components ... 21 Measuring Signals with High Frequency Components ... 21 Measuring Time Between Two Points ... 22 Measuring Frequencies ... 23 Measuring Pulse Rise and Fall Times ... 23 Measuring Phase Differences ... 24 Displaying Lissajous Patterns ... 25 FUSE REPLACEMENT, CHANGING VOLTAGE REQUIREMENTS ... 27 FUSE REPLACEMENT ... 27 CHANGING VOLTAGE REQUIREMENTS ... 27 SPECIFICATIONS ... 28 OPTIONAL EQUIPMENT ... 31 How to Attach the Accessory Bag ... 31

показать больше

Руководство по техническому обслуживанию
Hасто́льная кни́га тип:
Руководство по техническому обслуживанию
Страницы:
36
Размер:
6.07 Mbytes (6368400 Bytes)
Язык:
english
Пересмотр:
Hасто́льная кни́га ID:
Дата:
Качество:
Сканированный документ, читая частично плохо, частично не читается.
Дата загрузки:
2018 04 15
MD5:
d2273f383a8463f580b306575e3b0f17
Загрузки:
975

Информация

SPECIFICATIONS ... 3 SAFETY ... 6 CIRCUIT DESCRIPTION ... 7 BLOCK DIAGRAM ... 9 ADJUSTMENT ... 10 TROUBLESHOOTING ... 15 PARTS LIST ... 20 DISASSEMBLY ... 21 PARTS LIST (ELECTRICAL) ... 22 SCHEMATIC DIAGRAM/WAVEFORM ... 26 P.C. BOARD ... 31 SEMICONDUCTORS ... 33

показать больше