Информация по оборудованию:
Weinmann MODUL CapnoVol WM 22400 Спирометр | ||
---|---|---|
Производитель: |
Weinmann |
|
Модель: | MODUL CapnoVol WM 22400 | |
Дата: | 2009 | |
Категория: | Медицинское и биомедицинское оборудование | |
Группа: | Спирометр | |
Описание: | ||
Информация: | ||
MODUL CapnoVol is a device for measuring
respiratory parameters on exhalation.
The following are shown as figures:
•
tidal volume (TVe)
•
minute volume (MVe)
•
respiratory frequency (AF)
•
ratio of inspiration to exhalation (I:E)
•
carbon dioxide concentration at the end of
exhalation (etCO2)
The following is shown in the form of a graph:
•
current carbon dioxide concentration
(capnogram).
MODUL CapnoVol can be used in a permanent
location or on a mobile basis both indoors and
outdoors.
|
Эти руководства доступны для вышеуказанного оборудования:
Weinmann -- MODUL CapnoVol WM 22400 -- Руководство по техническому обслуживанию | ||
---|---|---|
Руководство Тип: | Руководство по техническому обслуживанию | ![]() |
Страницы: | 44 | |
Размер: | 3.14 Mbytes (3290779 Bytes) | |
Язык: | английский | |
Редакция: | ||
Manual-ID/Number: | WM 16829a | |
Дата: | 01 Январь 2009 | |
Качество: | Электронный документ, ни сканирование, очень хорошо читается. | |
Дата публикации: | 28 Февраль 2018 | |
MD5: | 938d0fb46b3dd41159517f154d11f03d | |
Скачиваний: | 228 начиная с 28 Февраль 2018 | |
Информация: | ||
Introduction ... 3
1. Overview ... 4
2. Description of device ... 5
2.1 Intended purpose ... 5
2.2 Description of function ... 5
3. Hygiene treatment ... .
6
3.1 Intervals ... .
6
3.2 MODUL CapnoVol and sensor cable .
6
3.3 Individual parts ... .
7
4. Test the device ... 8
4.1 Test material required ... 8
4.2 Preparation for testing ... 8
4.3 Enter device data ... 9
4.4 Test leaktightness ... 9
4.5 Test device self-test ... 10
4.6 Test the infrared interface ... 10
4.7 Test display elements ... 10
4.8 Test input elements ... 11
4.9 Test battery charging ... 11
4.10 Test flow measurement ... 12
4.11 Test occlusion alarm ... 12
4.12 Test CO2 measurement ... 13
4.13 Test system clock ... 14
4.14 Documentation ... 14
5. Servicing ... .
15
5.1 Intervals and scope ... .
15
5.2 Change battery ... .
16
5.3 Change O-rings of plug connection. .
16
5.4 Change O-rings of oxygen duct inlet .
17
5.5 Calibrate O2 sensor ... .
17
5.6 Storage ... .
19
5.7 Disposal ... .
19
6. Troubleshooting ... 20
7. Repair information and repair instructions
22
7.1 General ... .
22
7.2 Open the device ... .
22
7.3 Close the device ... .
23
7.4 Replace the Capno connecting
adapter ... .
24
7.5 Replace Nafion tube ... .
25
7.6 Replace main circuit board and/or
CAP 100 circuit board ... .
25
7.7 Replace fuses ... .
28
7.8 Replace connecting tube for oxygen
duct ... .
29
7.9 Replace display circuit board ... .
31
7.10 Replace infrared circuit board ... .
32
7.11 Replace top part of housing ... .
34
8. Replacement parts ... 35
8.1 Replacement parts list ... 35
8.2 Parts to be changed when servicing . 36
9. Tools and testing equipment
... .
37
9.1 General tools ... .
... .
37
9.2 Special tools ... .
... .
37
9.3 Testing equipment . . .
... .
38
10. Technical data ... 39
11. Service record ... 41
| ||
![]() | ||
Скачать бесплатно | ||