Keithley 2015 Multímetro digital
Fabricante:
Modelo:
2015
Data:
1999
Categoria:
Grupo:
Descrição:
THD Multimeter

Informação

Feature overview The Model 2015 is a 6 1⁄2-digit high-performance digital multimeter. It has 0.002% 90-day basic DC voltage accuracy and 0.008% 90-day basic resistance accuracy. At 6 1⁄2-digits, the multimeter delivers 50 triggered readings/sec over the IEEE-488 bus. At 4 1⁄2-digits, it can read up to 2000 readings/sec into its internal buffer. The Model 2015 has broad measurement ranges: THD, THD+n, and SINAD from 20Hz to 50kHz with 0.0001% (0.00001 dB) resolution. Frequency spectrum analysis from 20Hz to 50kHz (Model 2015P only). DC voltage from 0.1μV to 1000V. AC (RMS) voltage from 0.1μV to 750V, 1000V peak. DC current from 10nA to 3A. AC (RMS) current from 1μA to 3A. Two and four-wire resistance from 100μ Ω to 120MΩ. Frequency from 3Hz to 500kHz. Thermocouple temperature from -200°C to +1372°C. Some additional capabilities of the Model 2015 include: Full range of functions — In addition to those listed above, the Model 2015 functions include period, dB, dBm, continuity, diode testing, mX+b, and percent. Optional scanning — For external scanning, the Model 2015 is compatible with Keithley's Model 7001 and 7002 switch matrices and cards. Programming language and remote interfaces — The Model 2015 has the SCPI programming language and two remote Interface ports (IEEE-488/GPIB and RS-232C). Reading and setup storage — Up to 1024 readings and two setups (user and factory defaults) can be stored and recalled. Closed-cover calibration — The instrument can be calibrated either from the front panel or remote Interface.

mostrar mais

Manual de serviço
Tipo de manual:
Manual de serviço
Páginas:
158
Tamanho:
1.60 Mbytes (1673234 Bytes)
Idioma:
english
Revisão:
C
ID de manual:
2015-902-01
Data:
1999 06 01
Qualidade:
Documento eletrônico, digitalização, bem legível.
Data de upload:
2018 08 22
MD5:
4e64614a35918caceab9d30ddc838c1f
Downloads:
508
Manual do Usuário
Tipo de manual:
Manual do Usuário
Páginas:
46
Tamanho:
420.71 Kbytes (430803 Bytes)
Idioma:
english
Revisão:
A
ID de manual:
2015-903-01
Data:
2001 12 01
Qualidade:
Documento eletrônico, digitalização, bem legível.
Data de upload:
2018 08 22
MD5:
51b7fe31cfdfce71a439bb6c133ee45b
Downloads:
1213

Informação

AC Signal Analysis Using Models 2015 2015-P, and 2016 THD Multimeters Quick Reference Guide About this guide This guide is designed to familiarize users with basic Model 2015/2015-P 2016/operations to analyze an AC input signal. Operations include harmonic distortion measurements, standard AC volts and frequency measurements, and frequency spectrum analysis (Model 2015-P only). This guide covers front panel operation and remote operation over the GPIB or RS-232. The SCPI commands provided are generic; actual syntax depends on the test programming lan- guage being used. Information in this guide is organized as follows: Measurements overview – Summarizes the measurements used to analyze an AC input signal. Measuring harmonic distortion: Harmonic distortion calculations – Shows how harmonic distortion is calculated for the three measurement types; THD, THD + noise, and SINAD. Distortion measurement operations – Covers the various operations (front panel and remote commands) used to configure and measure distortion. Distortion measurement examples – Includes an example to measure total harmonic distortion (THD), and an example that uses a source sweep to measure distortion and RMS volts. Measuring AC volts and frequency – Provides the basic procedure to measure AC volts or frequency. Analyzing frequency spectrum (Model 2015-P only): Basic peak analysis – Covers the commands used to measure the peak amplitudes of the frequencies in the spectrum. Includes a remote command sequence example to find and measure the frequencies that have the three highest amplitudes. Delta function – Covers the commands to measure the difference in frequency and amplitude between two frequency pointer positions. Includes a command sequence example. Frequency list analysis – Covers the commands to create a frequency list and return the amplitudes of the listed frequencies. Includes a command sequence example.

mostrar mais

Manual do Usuário
Tipo de manual:
Manual do Usuário
Páginas:
2
Tamanho:
7.31 Kbytes (7486 Bytes)
Idioma:
english
Revisão:
A
ID de manual:
PA-698
Data:
1999 11 01
Qualidade:
Documento eletrônico, digitalização, bem legível.
Data de upload:
2018 08 22
MD5:
555d5cc9afde561bb5504af7f2fd3031
Downloads:
770

Informação

Measuring background noise in the presence of a signal with the Models 2015 and 2016

mostrar mais

Manual do Usuário
Tipo de manual:
Manual do Usuário
Páginas:
284
Tamanho:
2.86 Mbytes (2999749 Bytes)
Idioma:
english
Revisão:
E
ID de manual:
2015-900-01
Data:
2001 12 01
Qualidade:
Documento eletrônico, digitalização, bem legível.
Data de upload:
2018 08 22
MD5:
5e84f2afdbc92fe28aa621c8d57d6dfd
Downloads:
801

Informação

When this manual refers to the Model 2015 it is also referring to the Model 2015P, Information that pertains exclusively to the Model 2015P will be clearly indicated.