Telecommunications Techniques Corporation T-Berd 209 OSP Analyzer
Fabricante:
Modelo:
T-Berd 209 OSP
Data:
1995
Categoria:
Grupo:
Descrição:
T-Carrier Analyzer

Informação

The T-BERD 209osp is a portable test instrument that comprehensively analyzes T1 transmission systems. Designed for outside plant testing, the T-BERD 209osp may be used during circuit installation, acceptance testing, and fault isolation. Weather-resistant construction permits the T-Berd 209 OSP to operate in harsh environments. A membrane-switch front panel and a seamless, molded plastic case protects the T-BERD 209osp against the entry of water and debris. All connections, where water or dirt might be introduced, are isolated from the mainframe electronics by a water-resistant barrier. AUTOTEST™ feature performs a sequence of automated tests on a T1 circuit. These tests include: BRIDGTAP automated pattern sequence, Repeater test, optional DC measurements tests, and optional TDR test. This feature requires the T-BERD T1 Repeater Adaptor accessory. Automated BRIDGTAP™ pattern sequence detects bridge taps on a T1 span by automatically generating 21 test patterns and monitoring the returned signal for errors. Automated MULTIPAT™ pattern sequence generates five standard test patterns in 15 minutes. This feature eliminates the need to perform separate tests with each pattern. D1D, D4, ESF, SLC-96, and unframed framing patterns offer compatibility with a variety of framing formats. Two front panel displays provide verification of instrument configuration and test results. Repeater test verifies each side of a repeater with PASS/FAIL results. This feature requires the T-BERD T1 Repeater Adaptor accessory. Logic error, bipolar violation, and frame error analysis are performed simultaneously. Complete signal analysis includes signal level, timing slips, received clock frequency, and simplex current measurements. In-band and out-of-band ESF loopback codes enable the instrument to loopback or emulate devices that accept either in-band or out-of-band datalink loop codes. Bit-Patterned Message (BPM) recognition enables the T-BERD 209osp to identify and display BPMs from the ESF datalink in accordance with ANSI T1.403. In addition, the T-BERD 209osp can generate BPMs. SUMMARY category displays either ALL RESULTS OK or any out-of-specification or non-zero results, eliminating the need to search through long lists of test results. AUTO mode automatically configures the T-BERD 209osp to synchronize to the received T1 signal. No setup is required when monitoring live circuits. Logic error and bipolar violation (BPV) insertion enables the T-BERD 209osp to simulate errors. Line build-out (LBO) selections add troubleshooting capability to uncover marginal problems such as cable crosstalk and bridge taps. Print capability generates instrument setup, test results, and TDR trace printouts. Rechargeable lead-acid battery provides eight to ten hours of continuous cord-free operation.

mostrar mais

Manual do Usuário
Tipo de manual:
Manual do Usuário
Páginas:
280
Tamanho:
911.48 Kbytes (933357 Bytes)
Idioma:
english
Revisão:
G
ID de manual:
50-11825-01
Data:
1995 07 01
Qualidade:
Scaned documento, todas legível.
Data de upload:
2017 01 15
MD5:
1fc67131b2f9da6c53afbde8dacbf06f
Downloads:
661

Informação

This manual provides information about the physical features, functional operation, and specifications of the Telecommunications Techniques Corporation (TTC) T-BERD 209osp T-Carrier Analyzer. In addition to this manual, a T-BERD 209osp User’s Guide provides information on setting up and operating the T-BERD 209osp in a number of outside plant applications.

mostrar mais

Manual do Usuário
Tipo de manual:
Manual do Usuário
Páginas:
142
Tamanho:
3.56 Mbytes (3737177 Bytes)
Idioma:
english
Revisão:
G
ID de manual:
50-12540-01
Data:
1995 07 01
Qualidade:
Documento Scaned, a leitura parcialmente mal, não parcialmente legível.
Data de upload:
2017 01 15
MD5:
d581a178e9b5eb512088703229b96a2d
Downloads:
866

Informação

INTRODUCTION,, ... « ... 1 BASIC SETUPS 1. CONNECTING THE T-BERD 2090SP AT MID-SPAN ... 1 2. GENERATING PRINTOUTS ... 4 3. TIMED TEST SETUP ... 6 APPLICATIONS TESTING T1 NETWORKS 4. IN-SERVICE MONITORING ... 11 5. NIU/CSU LOOPBACK TESTING ... 14 6. LOSS TESTING ... 22 7. CSU EMULATION ... 26 8. MEASURING T1 TIMING SLIPS ... 30 9. REPEATER TESTING ... 32 10. AUTOTEST ... 34 11. START UP TESTING OF MULTIPLE T1 LINES ... 36 DC TESTING 12. DC TESTING ... 41 TDR TESTING 13. TDR TESTING FOR CABLE PAIR FAULTS ... 47 ADVANCED TESTING 14. MONITORING DSO AND SIGNALING BITS ... 55 15. TESTING FRACTIONAL T1 NETWORKS ... 59 16. REMOTE TESTING WITH PERFORMANCE MONITORING NIUS ... 64 17 JESTING SPANS WITH INTELLIGENT REPEATERS ... 67 HDSL TESTING 18. VERIFYING CABLE LENGTH ... 75 19. MEASURING LOSS ... 77 20. MEASURING SIGNAL POWER ... 78 21. HTU LOOPBACK TESTING ... 79 22. MONITORING DLC SHELF PERFORMANCE ... 85 23. IN-SERVICE REMOTE TERMINAL ALARM VERIFICATION ... 91 24. VERIFY RING GENERATION AND CIRCUIT CONTINUITY ... 98 25. VERIFY CHANNEL SIGNALING AND VF CONTINUITY ... 105 26. IN-SERVICE SHELF BIT ERROR RATE TESTING ... 111 27. CHECKING SLC MODE II TIMESLOT CHANNEL ASSIGNMENTS ... 119 ISDN/DDS LOCAL LOOP TESTING 28. DIGITAL DATA SERVICE (DOS) LOCAL LOOP TESTING ... 125 29. ISDN NOCAL LOOP TESTING ... 130 1. TESTING FROM MID-SPAN ... 2 2. IN-SERVICE MONITORING SETUP ... 11 3. CSU LOOPBACK TESTING FROM A DSX-1 PATCH PANEL ... 15 4. NIU LOOPBACK TESTING WITH THE T-BERD T1 REPEATER ADAPTOR ... 16 5. LOSS TESTING SETUP ... 23 6. CSU EMULATION SETUP ... 27 7. MEASURING T1 TIMING SLIPS ... 30 8. START UP TESTING OF MULTIPLE T1 LINES ... 37 9. DC VOLTAGE TEST GRAPHIC DISPLAY ... 42 10. TDR TESTING FROM A MID-SPAN REPEATER ... 49 11. INITIAL TDR TEST RESULT DISPLAY ... 51 12. MAGNIFIED TDR DISPLAY ... 51 13. VERIFYING THE SECOND CABLE PAIR FAULT ... 52 14. SINGLE TRACE TDR PRINTOUT ... 53 15. DUAL TRACE TDR PRINTOUT ... 54 16. TDR CONTROLS AND RESULTS PRINTOUTS ... 54 17. DSO CHANNEL MONITOR SETUP ... 55 18. FT1 OUT-OF-SERVICE TESTING FROM A DSX-1 PATCH PANEL ... 59 19. SMART NIU TESTING SETUP ... 64 20. TESTING INTELLIGENT REPEATER SPANS ... 69 21. MEASURING HDSL CIRCUIT CABLE LENGTH ... 75 22. MEASURING HDSL CIRCUIT SIGNAL LOSS ... 77 23. MEASURING HDSL CIRCUIT SIGNAL POWER ... 78 24. TESTING HDSL EQUIPMENT SPANS ... 80 25. MONITORING DLC SHELF PERFORMANCE ... 85 26. IN-SERVICE REMOTE TERMINAL ALARM VERIFICATION ... 91 27. TESTING RING GENERATORS AND LOCAL LOOPS ... 98 28. TESTING CHANNEL SIGNALING AND VF CONTINUITY ... 105 29. IN-SERVICE SHELF TESTING ... 111 30. CHECKING SLC MODE 2 TIME SLOT MAPPING ... 119 TASLE.S 1. T1 CIRCUIT TEST LOCATIONS ... 1 2. MULTIPAT AND BRIDGTAP TEST RESULTS ... 20 3. SIGNAL LEVEL TEST LOCATIONS ... 24 4. SELECTABLE CABLE TYPES ... 48

mostrar mais