Informação
ELECTRONIC VACUUM TUBE VOLTMETER KIT
FEATURES
• Push-Pull Balanced-Bridge Meter Circuit
Assures Accuracy and Protection
• 11-Megohm Input Resistance Minimizes
Circuit Loading—Gives True Readings
• Measures BOTH Peak-to-Peak and RMS
AC Voltages in 7 Ranges Each
• Single Zero-Adjustment Control for all
Functions and all Ranges
• Positive and Negative DC Function Switch Positions Eliminate Lead Reversal
• Zero-Center Scale for Alignment of TV and FM Discriminator Circuits
• Transformer-Type Power Supply for Line
Isolation and Operating Safety
• Calibrates Without Removing Cabinet
• Film-Type 1% Precision Resistors
Outstanding in both performance and value .... offering all
the quality that years of experience and research in
instrument development can provide . . . having all the
modern, advanced features needed for all-around efficiency
of electronics servicing . . . this is your Knight-Kit kit'>Knight-Kit VTVM.
Provides entirely electronic, direct-reading measurement of
AC voltage (BOTH Peak-to-Peak and RMS values), DC voltage,
decibels and resistance on a rugged, highly legible,
two-color 4y2" fu11-view meter. Invaluable for signal
tracing, for alignment, for voltage and resistance
measurements in AM/FM Radio or Tuner television and hi-fi
sets, for checking frequency response, for continuity tests,
and for servicing electrical equipment.
Feature highlights include: film-type 1% precision resistors
and multipliers; low-leakage function and range switches;
finest-grade printed circuit board; 3 separate test leads
for AC-Ohms, DC, and Common; heavy-gauge steel case with
rugged panel; Pilot Radio and Tube Corporation light; transformer-operated Power Supply for line isolation and safety; standard 1%-volt “C" battery;
200-microamp meter movement; carrying strap; and
premium-quality parts.
Circuitry boasts: push-pull balanced-bridge for maximum
accuracy and meter protection; DC polarity-reversing
switching; 11-megohm input resistance to reduce circuit
loading to a minimum and assure true readings; zero-center
scale; direct-reading decibel scale; highly sensitive DC Amplifier to allow resistance measurements as high as 1000
megohms using only the 1>£ volt battery — eliminating danger
to delicate apparatus under test; single zero-adjustment
control for all functions and ranges; and calibration
without removing internal chassis from cabinet.
1 Manual
Manual do usuário
Tipo manual:
Manual do usuário
Páginas:
32
Tamanho:
8,2 MB
Idioma:
inglês
Revisão:
Manual-ID:
Data:
Janeiro 1966
Qualidade:
Documento digitalizado, com leitura parcialmente ruim e parcialmente ilegível.
Data de upload:
26 de Dezembro de 2016
MD5:
30f73db7-a3bb-c815-03bc-72fda459ae27
Informação
Assembly Manual
Downloads:
1051
Downloads do mês passado:
5
Download
knight-kit--kg-620--user--ID8174.pdf