Hewlett Packard - HP 8563A - Analisador de espectro
Fabricante:
Nenhuma imagem disponível!
Talvez você possa
carregar uma foto
para o
Hewlett Packard HP 8563A ?
Se você tiver outros manuais para o
Hewlett Packard HP 8563A
você pode
carregar os arquivos aqui.
.
Equipamento:
HP 8563A
Data:
Categoria:
Grupo:
Subgrupo:
Informação
HP 8560 Series Spectrum Analyzers
These portable spectrum analyzers are HP’s highest performing portables. They combine MIL-rugged packaging, synthesized tuning, and HP’s traditional ease of use as standard features.
The HP 8560A* has a frequency range of 50 Hz to 2.9 GHz. A built-in tracking generator is optional. The HP 8561B* extends from 50 Hz to 6.5 GHz. For higher, preselected frequency coverage, the HP 8562A and 8563A* operate from 9 kHz to 22 GHz or to 26.5 GHz with option 026. Using HP 11974A series millimeter mixers, preselected coverage reaches 75 GHz, and with other mixers, unpreselected coverage can be extended to 325 GHz. (See page 187 for information on HP millimeter mixers.)
Rugged For Field Service
The HP 8560 series meets all MIL-T-28800C requirements, including those for temperature, pulse shock, and transit drop. These analyzers are warmed up and running in only five minutes. They fully meet specifications in temperatures from —10 degrees to +55 degrees C. They can withstand 30 g's of shock.
Narrow Digital Resolution Bandwidths
For fast, accurate measurements of closely spaced signals, the HP 8560A, 8561B, and 8563A feature digital 10-, 30-, and 100-Hz resolution bandwidths. These bandwidths allow the analyzers to sweep up •Contact your HP sales representative for information about options for general export.
to 20 times faster than do conventional analog bandwidths. Digital bandwidths also provide the spectrum analyzer CRT with a calibrated measurement range of 100 dB.
Improved Frequency Accuracy
An optional precision frequency reference improves frequency accuracy to 150 Hz at 1 GHz after a 15 minute warmup ( 1 year aging).
Specified Pulse Response
These portable analyzers easily capture and accurately display short-duration radar pulses. Specified pulse-digitization uncertainty is 1.25 dB and typical repeatability is 0.2 dB.
Accessories
1 Manual
Folha de dados
Tipo manual:
Folha de dados
Páginas:
4
Tamanho:
368,6 KB
Idioma:
inglês
Revisão:
Manual-ID:
Data:
Qualidade:
Documento digitalizado, com leitura parcialmente ruim e parcialmente ilegível.
Data de upload:
22 de Outubro de 2020
MD5:
d2807f4b-c2ea-b0ee-087a-3fd7a4dcdb26
Downloads:
824