Telecommunications Techniques Corporation T-Berd 107A Analyzer
Fabricante:
Nenhuma foto disponível!
Talvez você possa carregar uma foto para os
Telecommunications Techniques Corporation T-Berd 107A ?
Se você tem outros manuais para os
Telecommunications Techniques Corporation T-Berd 107A você pode carregar os arquivos aqui .
Modelo:
T-Berd 107A
Data:
1994
Categoria:
Grupo:
Descrição:
T-Carrier Analyzer
Informação
The T-Berd 107 Ais a full-featured, hand-held T1 Test Set
designed for outside plant testing. It can be used during
circuit installation, acceptance testing, and fault
isolation. The T-Berd 107 A can monitor a T1 circuit without
interrupting service, generate and receive test patterns
during out-of-service circuit testing, and emulate a network
device, such as a Network Interface Unit (NIU) or Channel
Service Unit (CSU). In addition, the T-Berd 107 A detects
and isolates problems related to customer premises equipment
(e.g., NIU) and detects problems originating from the T1 span.
D1D, D4, ESF, and SLC-96™ framing patterns
offer compatibility with a variety of framing formats. An
unframed mode is also available for applications where
framing is not required.
Automated BRIDGTAP™ pattern sequence detects bridge taps on
a T1 span by automatically generating 21 test patterns and
monitoring the returned signal for errors.
Automated MULTIPAT™ pattern sequence generates five standard
test patterns with variable dura- tions that eliminate the
need to perform separate tests with each pattern.
Logic error, bipolar violation, and frame error (CRC error
if ESF framing) analysis are performed simultaneously with
the associated error rate and eirored seconds measurements.
Complete signal analysis includes signal level, timing
slips, received clock frequency, and simplex current
measurements.
In-band and ESF out-of-band loopback codes
enable the instrument to loopback or emulate devices that
accept eitherin-band or out-of-band loop codes.
Bit-Patterned Message (BPM) recognition enables the T-BERD
107A to identify and display BPMs from the ESI' datalink in
accordance with ANSI T1.403. In addition, the T-BERD 107A
can generate BPMs.
Channel drop feature displays user-selected DSO channel
signaling bits, data bits, and VF frequency/ level
measurements. In addition, the selected DSO channel is
dropped to the internal speaker and the VF OUT jack for
analysis by an external TIMS Test Set.
SUMMARY category display s either ALL RESULTS OK or any
out-of-specification or non-zero results, eliminating the
need to search through long lists of test results.
AUTO mode lets the T-BERD I07A configure itself to the
proper framing, coding, and pattern. No setup is required
when monitoring live circuits.
Logic error and bipolarviolation (BPV) insertion
enables the T-Berd 107 A to simulate span and equipment errors.
Line Build-Out selections add troubleshooting capability to
uncover marginal problems such as cable crosstalk and bridge
taps.
Rechargeable battery and AC power adapter
provide operating flexibility to meet different testing
needs. The lead-acid battery provides four hours of
continuous cord-free operation and can be recharged from the
T-Berd 107A AC power adapter.
VF OUT jack enables the T-Berd 107A to drop a voice
frequency signal from one channel to an external Test Set
for analy sis.
RS-232 Interface connector enables the T-Berd 107A to print
test results and test setup for various tests.
Tipo de manual:
Manual do Usuário
Páginas:
90
Tamanho:
7.72 Mbytes (8093069 Bytes)
Idioma:
english
Revisão:
C
ID de manual:
50-12742-01
Data:
1994 12 01
Qualidade:
Scaned documento, todas legível.
Data de upload:
2017 01 10
MD5:
3b761b558f1ba54a477f2d5e3c3b6ad0
Downloads:
593
Informação
User's Guide
The T-BERD107A User’s Guide offers an easy, direct method to
setup and operate the T-Berd 107 A within your network. It
presents the most often used test setups in complete and
concise steps. Illustrations, helpful notes, and
step-by-step procedures make this usee’s guide a unique aid
for new and experienced users.
This user’s guide is designed for the user who needs to know
the basics about setting up and operating the T-BERD
107Ainashort amount of time. If you are unfamiliar with the
instrument, please refer to the T-Berd 107A Reference Manual
for more detailed information. If you should require
additional help, call TTC Customer Service at (800) 638-2049.
This manual contains applications for the following T-BERD
107A options. The options used are identified at the
beginning of the application. One or more of the options may
be used in a single application.
# SLC Datalink Decode Option
® Advanced Stress Patterns Option
® Enhanced ESF Option
* Intelligent Network Support Option
9 Fractional T1 Option
This manual is organized into the following sections:
BASIC SETUPS — Describes setting up the T-Berd 107A to test
T1 circuits, printout hard cqpiesof test configurations and
test results, and perform timed testing.
APPLICATIONS —Presents setup procedures and results
interpretation for a number of T-Berd 107A applications.
Each application identifies the test scenario, the purpose
of the test, andtherequired Accessories or options. The
tests are grouped as follows:
- Testing T1 Networks
- Testing SLC-96™ Circuits
- Smart NIU Testing
- Intelligent Network Testing
Tipo de manual:
Manual do Usuário
Páginas:
286
Tamanho:
6.73 Mbytes (7058035 Bytes)
Idioma:
english
Revisão:
C
ID de manual:
50-12741-01
Data:
1994 12 01
Qualidade:
Documento Scaned, a leitura parcialmente mal, não parcialmente legível.
Data de upload:
2017 01 10
MD5:
46dbb12d3d844e444b54fbc8093412cd
Downloads:
473
Informação
This manual provides information about the physical
features, functional operation, and specifications of the
Telecommunications Techniques Corporation (TTC) T-BERD 107A
T-Carrier Analyzer.
In addition to this manual, a T-Berd 107A User’s Guide
provides information on setting up and operating the T-BERD
107A in a number of in- service and out-of-service applications.
1.1 INTRODUCTION ... 1-1
1.2 INSTRUMENT OVERVIEW ... 1-1
1.3 STANDARD FEATURES ... 1-2
1.4 OPTIONS ... 1-4
1.5 Accessories ... 1-5
1.6 CABLES ... 1-7
1.7 ORDERING INFORMATION ... 1-8
I I i MIHiJ:
2.1 UNPACKING AND INITIAL
INSPECTION ... 2-1
2.2 EQUIPMENT INCLUDED ... 2-1
2.3 WARNINGS AND CAUTIONS ... 2-2
2.4 POWER REQUIREMENTS ... 2-2
2.5 INSTRUMENT SELF-TEST/
CHECKOUT ... 2-5
2.6 MAINTENANCE ... 2-19
2.7 BATTERY REPLACEMENT ... 2-20
2.8 WARRANTY ... 2-22
2.9 EQUIPMENT RETURN
INSTRUCTIONS ... 2-24
3.1 OVERVIEW ... 3-1
3.2 MAINFRAME—TEST SETUP ... 3-3
3.3 MAINFRAME
—TEST CONNECTIONS ... 3-17
3.4 MAINFRAME — TEST RESULTS ... 3-21
3.5 MAINFRAME—TROUBLESHOOTING
CONTROLS ... 3-29
3.6 MAINFRAME — PRINTER CONTROL. 3-34
3.7 SLCDATALINK DECODE
OPTION — INTRODUCTION ... 3-35
3.8 SLCDATALINK DECODE OPTION
— TEST SETUP ... 3-35
3.9 SLCDATALINK DECODE OPTION
— TEST RESULTS ... 3-36
3.10 ADVANCED STRESS PATTERNS
OPTION —INTRODUCTION ... 3-39
3.11 ADVANCED STRESS PATTERNS
OPTION —TESTSETUP ... 3-39
3.12 ENHANCED ESFOPTION
— INTRODUCTION ... 3-43
3.13 ENHANCED ESF OPTION
— TEST SETUP ... 3-43
3.14 ENHANCED ESF OPTION
— TESTRESULTS ... 3-45
3.15 ENHANCED ESF OPTION
— PRINTER CONTROL ... 3-51
3.16 SMART LOOPBACK/COMMAND
CODES OPTION
—INTRODUCTION ... 3-53
3.17 SMART LOOPBACK/COMMAND
CODES OPTION —TEST SETUP ... 3-53
3.18 SMART LOOPBACK/COMMAND
CODES OPTION
—TROUBLESHOOTING ... 3-54
3.19 FRACTIONALT1 OPTION
— INTRODUCTION ... 3-55
3.20 FRACTIONAL T1 OPTION
— TEST SETUP ... 3-55
3.21 FRACTIONAL T1 OPTION
—TROUBLESHOOTING ... 3-5
4.1 INTRODUCTION ... 4-1
4.2 AUXILIARY FUNCTIONS ... 4-3
5.1 TESTRESULTS ... 5-1
5.2 SUMMARY CATEGORY ... 5-4
5.3 ERRORS CATEGORY ... 5-12
5.4 SIGNAL CATEGORY ... 5-15
5.5 TIMECATEGORY ... 5-19
5.6 DATAUNKCATEGORY ... 5-20
6.1 COMPATIBLE PRINTERS ... 6-1
6.2 PRINTER OPERATION ... 6-1
6.3 CONNECTING THE PRINTER ... 6-4
6.4 GENERATING A PRINTOUT ... 6-5
6.5 TYPES OF PRINTOUTS ... 6-7
7.1 INTRODUCTION ... 7-1
7.2 GENERAL SPECIFICATIONS ... 7-1
7.3 INPUT SPECIFICATIONS ... 7-2
7.4 OUTPUT SPECIFICATIONS ... 7-3
7.5 MEASUREMENTS ... 7-4
7.6 CONNECTORS ... 7-8
7.7 ALARM CRITERIA ... 7-8
7.8 PATTERN SPECIFICATIONS ... 7-10
7.9 LOOPCODES ... 7-12
7.10 GROUNDING ... 7-13
7.11 BATTERY ... 7-14