BK Precision 1786B Fonte de alimentação
Fabricante:
Nenhuma foto disponível!
Talvez você possa carregar uma foto para os
BK Precision 1786B ?
Se você tem outros manuais para os
BK Precision 1786B você pode carregar os arquivos aqui .
Modelo:
1786B
Data:
2005
Categoria:
Grupo:
Descrição:
Informação
The 1785B - 1788 Series power supplies are high performance
single-output programmable DC power supplies with
communication Interface. The combination of bench-top and
system features in these power supplies provides versatile
solutions for your design and test requirements.
Convenient bench-top features:
• Nice appearance, small-size and light weight
• VFD display
• Soft Rubber numeric keypad
• Adjustable & constant voltage outputs
• Adjustable & constant current outputs
• Output on/off
• High accuracy and high resolution
• Excellent load and line regulation
• Low ripple and noise
• Limit voltage protection
• Over current/temperature protection
• Sixteen operating states storage
• May be used in series or parallel modes with additional
power supplies
Tipo de manual:
Manual do Usuário
Páginas:
38
Tamanho:
753.33 Kbytes (771410 Bytes)
Idioma:
english
Revisão:
ID de manual:
481-534-9-001
Data:
2005 01 01
Qualidade:
Scaned documento, todas legível.
Data de upload:
2017 01 24
MD5:
e68ba91c485434906fe6bfe865193b52
Downloads:
1441
Informação
Quick
Reference ... 3
About your
safety ... 3
General
information ... 3
Protection from electric
shock ... 3
Definition of
users ... 3
Introduction
...
4
The Front Panel at a
Glance ... 5
Function keys
description ... 6
Menu description
...
6
Display
annunciators ... 6
The Rear Panel at a
Glance ... 7
Chapter 1 Quick
Start ... 8
1.1 Preliminary
Checkout ... 8
1.2 Output
Checkout ... 9
1.2.1 Voltage Output
Checkout ... 9
1.2.2 Current Output
Checkout ... 9
1.3 If the Power supply Does Not Turn
On ... 10
1.4 To Adjust the Carrying
Handle ... 10
1.5 To Rack Mount the
Instrument ... 11
Chapter 2
Specifications ... 12
2.1
Specifications ... 12
2.2 Supplemental
Characteristics ... 13
Chapter 3 Front-panel
Operation ... 15
3.1 Front-panel Operation
Overview ... 15
3.2 Constant Voltage
Operation ... 15
3.3 Constant Current
Operation ... 16
3.4 Saving and Recalling
Operation ... 16
3.5 Menu
Operation ... 16
Chapter 4 Remote Operation
Mode ... 19
4.1 Communication
setting ... 19
4.2 DB9 Interface
details ... 19
4.3 Frame
format ... 20
4.4 Communication
protocol ... 20
Chapter 5
Calibration ... 27
5.1 Configuration
... 28
5.2 Voltage calibration
... 28
5.3 Current
calibration ... 28
5.4 Reset to the default calibration
settings ... 29
Chapter 6 PV1785B_1788
Software ... 29
6.1
Introduction ... 29
6.2 System
installation ... 29
6.3 PV1785B_1788
Functions ... 30
6.3.1Configure the
system ... 31
6.3.2 Status
bar ... 31
6.3.3 Setting Voltage and
current ... 32
6.3.4. GO/NG Test
Function ... 33
6.3.5 Save and
Open ... 34
6.3.6 Present Voltage/Current
Chart ... 34
6.3.7. Chart
Description ... 34
Certification and
Warranty ... 4
Certification ...
Warranty ...
Limitation of
Warranty ...
Add Comment
Terms and Conditions
These terms and conditions contain rules about posting comments. By submitting a comment, you are declaring that you agree with these rules:
- Although the administrator will attempt to moderate comments, it is impossible for every comment to have been moderated at any given time.
- You acknowledge that all comments express the views and opinions of the original author and not those of the administrator.
- You agree not to post any material which is knowingly false, obscene, hateful, threatening, harassing or invasive of a person's privacy.
- The administrator has the right to edit, move or remove any comment for any reason and without notice.
Failure to comply with these rules may result in being banned from further commenting.
These terms and conditions are subject to change at any time and without notice.
Comments