LeCroy HFP1000 Sonda
Producent:
Model:
HFP1000
Data:
2008
Kategoria:
Grupa:
Opis:
High Frequency Probe

Informacja

PRODUCT DESCRIPTION The 1 GHz HFP1000 is a small, high frequency active Probe designed to meet today’s increasing demand for measurements on a variety of test points. With low input capacitance and high input resistance, circuit loading is minimized. The HFP1000 can be used with LeCroy’s WavePro TM, Waverunner TM and LC Series Oscilloscope with firmware version 8.7.0 or higher. When the Probe is used with any of these oscilloscopes, an AutoColor ID feature automatically illuminates the Probe head in the default trace color of the channel to which the Probe is connected, eliminating the need for color bands or other markers. With the ProBus Interface, the HFP1000 becomes an integral part of the Oscilloscope. The Probe can be controlled from the oscilloscope’s front panel. The Oscilloscope provides power to the probe, so there is no need for a separate Power supply or batteries. When used in combination with an ADPPS Power supply, the HFP1000 Probe can be used with non-LeCroy instruments. (See Section 4 for detailed operation with an ADPPS adapter). Note: The AutoColor ID feature will be disabled when the Probe is used with an ADPPS adapter or a LeCroy Oscilloscope with firmware version lower than 8.7.0. KEY BENEFITS • High frequency performance • Low input capacitance • Wide dynamic range • ProBus Interface • AutoColor feature matches the Probe color to the oscilloscope’s default trace color • Five interchangeable tips for probing a variety of test points (two standard, three optional accessories) • Replaceable Probe tip socket • Hands free probing with optional FreeHand Probe Holder

pokaż więcej

Instrukcja obsługi
Typ ręczny:
Instrukcja obsługi
Strony:
46
Rozmiar:
1.30 Mbytes (1360023 Bytes)
Język:
english
Rewizja:
F
Ręczny ID:
HFP1000-OM-E
Data:
2008 02 01
Jakość:
Dokument elektroniczny, bez skanowania, bardzo dobrze czytelne.
Data przesłania:
2021 01 07
MD5:
601092156d8ec6538c4686a83f4075c4
Pobrane:
150

Informacja

Safety Information Operator Safety ... 1–1 Conventions Used in this Manual ... 1–1 Overview Product Description ... 2–1 Key Benefits ... 2–1 Standard Accessories ... 2–2 Optional Accessories ... 2–2 Features and Accessories Probe Head ... 3–1 AutoColor ID ... 3–1 Description of Standard and Optional Accessories ... 3–1 A. Tips ... 3–2 B. Clips ... 3–3 C. Leads ... 3–4 D. Probe Holder ... 3–5 E. Cartridges ... 3–6 Operation Handling the Probe ... 4–1 Connecting the Probe to the Test Instrument ... 4–1 Connecting the Probe to the Test Circuit ... 4–1 Operation with a LeCroy Oscilloscope ... 4–1 Use with Non-LeCroy Instruments ... 4–2 Use with Older LeCroy Instruments ... 4–2 High Frequency Measurements Input Loading ... 5–1 Inductive Loading (Lead Length) ... 5–1 Capacitive Loading ... 5–3 Care and Maintenance Cleaning ... 6–1 Calibration Interval ... 6–1 Service Strategy ... 6–1 Returning a Defective Probe ... 6–1 Replacement Parts ... 6–2 Performance Verification Test Equipment Required ... 7–1 Preliminary Procedure ... 7–2 Functional Check ... 7–3 Procedure ... 7–4 A. Output Zero Voltage ... 7–4 B. LF Attenuation Accuracy ... 7–5 Adjustment Procedure Introduction ... 8–1 Test Equipment Required ... 8–1 Preliminary Procedure ... 8–2 Procedure ... 8–3 A. Adjust Output Zero ... 8–3 B. Verify Calibration ... 8–4 Specifications Nominal Characteristics ... 9–1 Warranted Characteristics ... 9–1 Typical Characteristics ... 9–1 Environmental Characteristics ... 9–2 Physical Characteristics ... 9–2 Compliance and Certifications ... 9–4 Appendix A Performance Verification Test Record ... A–1 Equipment Used: ... A–1 HFP1000 Test Record ... A–2

pokaż więcej