Hewlett Packard HP 54201A Oscyloskop
Producent:
Model:
HP 54201A
Data:
1986
Kategoria:
Grupa:
Opis:
Digitizing Oscilloscope

Informacja

The HP 54201A and HP 54201D Digitizing Oscilloscopes are dedicated, two-channel, simultaneous, waveform acquiring digital storage oscilloscopes with full HP-IB programmability, digitized waveform data output, and resident parametric waveform measurements. HP 54201 A/D - General Information The HP 54201 A/D is a general purpose digitizing Oscilloscope with 300 MHz repetitive bandwidth and a single-shot digital storage bandwidth of 50 MHz (200 rneqasamples/second) with infinite store time and waveform data output. It also provides parametric information about the analog characteristics of waveforms. The HP 54201 D has all the features of the HP 54201A with the addition of parallel and serial logic trigger qualification capabilities. The HP 54201 D includes 3 pods, each containing 8 bit + 1 parity bit + clock organization. The key features of the HP 54201 A/D Digitizing Oscilloscopes are: • 300 MHz repetitive bandwidth with ±200 ps time-interval accuracy. • 200 rneqasarnples/second sample rate, 50 MHz single-shot bandwidth using post capture data interpolation. • Capture two channels simultaneously. • Holdott-by-events to trigger acquisition after a specified number of events. • Pre-trigger viewing. • All front panel controllable parameters can be programmed via HP-IB. • Continuously updated automatic waveform parameter measurements with user-defined thresholds. • Waveform math: Ch1 +Ch2 and Ch1-Ch2. • Set up aids such as automatic waveform scaling, ECl/TTl preset levels, and save/recall of front-panel setups. • One button hardcopy to HP-IB printers and plotters. • Digital logic trigger qualification (HP 54201 D only).

pokaż więcej

Instrukcja obsługi
Typ ręczny:
Instrukcja obsługi
Strony:
250
Rozmiar:
6.11 Mbytes (6405232 Bytes)
Język:
english
Rewizja:
Ręczny ID:
54201-90901
Data:
1986 01 01
Jakość:
Skanowany dokument, wszystko czytelne.
Data przesłania:
2020 06 07
MD5:
6c5345963b14ff22983caf6d6ebebe9e
Pobrane:
2129

Informacja

Operating and Programming Manual This manual contains information concerning the operation and programming of the HP 54201A and HP 54201 D Digitizing Oscilloscopes. When information concerns both models the system will be referred to as the HP 54201A.D. MANUAL ORGANIZATION Section 1, General Information. This section contains a description of this manual and the instrument. Section 2, Getting Started. This section explains how to prepare the HP 54201A.D for use. Section 3, Front Panel Controls and Menus. This section familiarizes the user with the front panel controls and menu structures of the HP 54201A.D. Section 4, Front Panel Exercises. This section provides step-by-step exercises to familiarize the user with making measurements from the front panel of the HP 54201A.D. Section 5, State Triggering with the HP 54201D, This section discusses the operation of the state triggering feature of the HP 54201 D. Section 6, Peripherals. This section provides information for making hardcopy prints of the HP 54201A/D display using a plotter or graphic printer. Section 7, Remote Control Operation. This section discusses the remote operation of the HP 54201A/D over HP-IB, including compatibility, remote/local modes, local lockout, learn and calibration strings, and notation and definitions. This section should be reviewed before writing programs for this instrument. Section 8, Programming the HP 54201A.D. This section provides programming instructions for the instrument, including the instruction set, syntax diagrams, and other detail programming reference information.

pokaż więcej

Instrukcja serwisowa
Typ ręczny:
Instrukcja serwisowa
Strony:
173
Rozmiar:
3.94 Mbytes (4135762 Bytes)
Język:
english
Rewizja:
Ręczny ID:
54201-90902
Data:
1986 01 01
Jakość:
Skanowany dokument, wszystko czytelne.
Data przesłania:
2020 06 07
MD5:
fba8240cd5dfc877186f9625beda6bc3
Pobrane:
740

Informacja

This manual applies directly to instruments with serial number prefixes: HP 54201 A; 2602A Hp 54201 D; 2602A This manual contains technical information concerning the installation, performance testing, adjustments, and servicing of the HP 54201A and HP 54201 D Digitizing Oscilloscopes. When information concerns both models the system will be referred to as the HP 54201A.D. MANUAL ORGANIZATION Section 1, General Information. This section contains a description of this manual and the Instrument. This section also gives the specifications, general characteristics, operating characteristics and recommended test equipment for the HP 54201A.D. Section 2, Installation. This section explains how to prepare the HP 54201 A/D for use. Section 3, Performance Tests. This section describes both the self test capabilities of the HP 54201 A/D as well as the procedures for the full Performance Test. Section 4, Adjustments. The HP 54201 A/D requires several adjustments to restore specified performance after some major repairs have been made. This section provides the necessary adjustment procedures. Section 5, Replaceable Parts. This section contains ordering information and a list of all replaceable parts in the HP 54201A.D system. Section 6, Service. This section contains disassembly and assembly procedures and documentation and procedures for isolation and replacement of faulty circuit boards. Service Group 6A, Power supply. This section contains block diagrams and component level theory, troubleshooting and schematic information necessary to service the HP 54201 A/D power supply. Appendix A, Self Test Documentation. This section contains an overview of how the HP 54201A.D self tests work and what portions of the HP 54201 A/D circuitry they check.

pokaż więcej