Fluke - PM 6303A - LCR Meter
Producent:
Obraz 1 z 1
Jeśli masz jakieś inne zdjęcia lub instrukcje do
Fluke PM 6303A
możesz
przesłać pliki tutaj.
Wyposażenie:
PM 6303A
Data:
1995
Kategoria:
Grupa:
Podgrupa:
Informacja
MAIN FEATURES
The PM6303A Automatic RCL Meter is used for precise
measurements of resistance, capacitance and inductance. The
instrument provides auto-function and auto-ranging facility.
It allows fast and high precision measurements of passive
components over a wide range.
The component to be measured is connected to the instrument
via front panel test posts, the PM 9541A four-wire test
cable, or the PM 9542A four-terminal test adapter. The
Adapter PM 9542SMD or the PM 9540/7WE SMD Tweezers for
surface-mounted components are also available.
The measurement result, the numerical value, dimension, and
the equivalent circuit symbol, is immediately displayed on
the large four-digit liquid-crystal display (LCD), which is
updated at a rate of two measurements per second.
A microprocessor controls the measurement process, computes
the measurement value, and transfers the result to the display.
In the AUTO mode the dominant parameter, either R, C, or L
of the component under test is automatically selected for
display.
For example, for an inductance with a quality factor Q
between 1 and 500, the instrument indicates the measurement
value of the series inductance and as equivalent circuit
symbol, the series connection of a resistance and an inductance.
In addition to the AUTO mode, eight component parameters can
be selected manually by pressing pushbuttons:
■ Quality factor Q
■ Dissipation factor D
■ Parallel resistance Rp
■ Series resistance Rs
■ Impedance Z
■ Parallel capacitance Cp or parallel inductance Lp
■ Series capacitance Cs or series inductance Ls
■ Phase angle
An internal DC BIAS voltage can be added to the measurement
voltage for electrolytic capacitors.
The PM6303A RCL Meter is especially suited for use in
laboratories, for quality control, in service workshops, and
for educational purposes.
3 podręczniki
Podręcznik użytkownika
Typ ręczny:
Podręcznik użytkownika
Strony:
90
Rozmiar:
1,7 MB
Język:
angielski
Poprawka:
Manual-ID:
951111
Data:
Styczeń 1995
Jakość:
Zeskanowany dokument, wszystko czytelne.
Data przesłania:
20 stycznia 2018
MD5:
5fd0504e-e986-6009-2a39-3916d833d259
Informacja
SHIPMENT NOTE AND INITIAL INSPECTION
1 INSTALLATION AND SAFETY INSTRUCTIONS 1 - 1
1.1 SAFETY INSTRUCTIONS ' 1 - 1
1.1.1 Maintenance and Repair 1 - 1
1.1.2 Grounding (Earthing) 1-2
1.1.3 Connections 1 - 2
1.1.4 Line Voltage Setting and Fuses •I _ 3
1.2 OPERATING POSITION OF THE INSTRUMENT 1 “4
1.3 RADIO INTERFERENCE SUPPRESSION • 1—4
2 MAIN FEATURES 2 - 1
3 OPERATING INSTRUCTIONS 3 - 1
3.1 GENERAL INFORMATION 3 _ 1
3.2 TURNING THE INSTRUMENT ON 3 - 1
3.3 SELF-TEST ROUTINE 3 - 1
3.4 BRIEF CHECKING PROCEDURE 3-2
3.4.1 General 3-2
3.4.2 Functional Test 3-3
3.5 OPERATION AND APPLICATION 3-5
3.5.1 Control Elements, Display and Connections 3-5
3.5.2 Measurement Setup and Accessories 3-8
3.5.3 Automatic Zero Trim 3-13
3.5.4 Component Measurement 3-15
3.5. Out-of-Range and Error Messages 3-17
3.5.6 Component Measurement at Range Limits 3-18
3.6 MEASUREMENT PRINCIPLE 3-21
3.7 SELF DIAGNOSTICS 3-27
4 CHARACTERISTICS 4-1
4.1 SAFETY AND EMC Electronic Measurements Corporation REQUIREMENTS 4 - 1
4.2 PERFORMANCE SPECIFICATIONS 4-2
4.3 Power Supply 4-6
4.4 ENVIRONMENTAL CONDITIONS 4-6
4.5 SAFETY & QUALITY DATA; CABINET 4-8
4.6 Accessories 4-9
5 PERFORMANCE TEST
5.1 INTRODUCTION
5.2 RECOMMENDED TEST EQUIPMENT
5.3 SELF-TEST ROUTINE, ERROR MESSAGES
5.4 PERFORMANCE VERIFICATION
5.4.1 Measurement Voltage
5.4.2 Measurement Frequency
5.4.3 Open-Circuit Trimming
5.4.4 Short-Circuit Trimming
5.4.5 Resistor Measurement
5.4.6 Capacitance/Inductance Measurement
6 LIMITED WARANTY & LIMITATION OF LIABILITY, DECLARATION
OF CONFORMITY 6 - 1
INSTALLATION AND SAFETY INSTRUCTIONS IN FOREIGN LANGUAGES
FIGURES
Fig. 1 Front view
Fig. 2 Rear view
Fig. 3 PM 9540/TWE, SMD Tweezers
Fig. 4 PM 9540/BAN, 4-wire test cable with banana plugs
Fig. 5 PM 9541 A, 4-wire test cable
Fig. 6 Single and double test posts
Fig. 7 PM 9542SMD, SMD Adapter
Fig. 8 PM 9542A, RCL Adapter
Pliki:
1110
Pobrania w zeszłym miesiącu:
4
Pobierz
fluke--pm-6303a--user--ID10142.pdf
Podręcznik użytkownika
Typ ręczny:
Podręcznik użytkownika
Strony:
247
Rozmiar:
18,3 MB
Język:
angielski
Poprawka:
2
Manual-ID:
4822 872 10158
Data:
Luty 1999
Jakość:
Zeskanowany dokument, wszystko czytelne.
Data przesłania:
28 stycznia 2018
MD5:
8ed68150-085b-4d12-5b02-9026e1018ea1
Informacja
1 INSTALLATION AND SAFETY INSTRUCTIONS
1.1 SAFETY INSTRUCTIONS
1.1.1 Maintenance and Repair
1.1.2 Grounding (Earthing)
1.1.3 Connections
1.1.4 Line Voltage Setting and Fuses
1.2 OPERATING POSITION OF THE INSTRUMENT
1.3 RADIO INTERFERENCE SUPPRESSION
2 MAIN FEATURES
3 OPERATING INSTRUCTIONS
3.1 GENERAL INFORMATION
3.2 TURNING THE INSTRUMENT ON
3.3 SELF-TEST ROUTINE
3.4 BRIEF CHECKING PROCEDURE
3.4.1 General
3.4.2 Functional Test
3.5 OPERATION AND APPLICATION
3.5.1 Control Elements, Display and Connections
3.5.2 Measurement Setup and Accessories 3.5.3 Automatic Zero Trim
3.5.4 Component Measurement
3.5. Out-of-Range and Error Messages
3.5.6 Component Measurement at Range Limits
3.6 MEASUREMENT PRINCIPLE
3.7 SELF DIAGNOSTICS
4 CHARACTERISTICS 4 - 1
4.1 SAFETY AND EMC Electronic Measurements Corporation REQUIREMENTS 4 - 1
4.2 PERFORMANCE SPECIFICATIONS 4-2
4.3 Power Supply 4-6
4.4 ENVIRONMENTAL CONDITIONS 4-6
4.5 SAFETY & QUALITY DATA; CABINET 4-8
4.6 Accessories 4-9
5 PERFORMANCE TEST 5-1
5.1 INTRODUCTION 5 - 1
5.2 RECOMMENDED TEST EQUIPMENT 5-1
5.3 SELF-TEST ROUTINE, ERROR MESSAGES 5-2
5.4 PERFORMANCE VERIFICATION 5-2
5.4.1 Measurement Voltage 5-2
5.4.2 Measurement Frequency 5-3
5.4.3 Open-Circuit Trimming 5-3
5.4.4 Short-Circuit Trimming 5-4
5.4.5 Resistor Measurement 5-4
5.4.6 Capacitance/Inductance Measurement 5-5
6 LIMITED WARANTY & LIMITATION OF LIABILITY, DECLARATION
OF CONFORMITY 6 - 1
INSTALLATION AND SAFETY INSTRUCTIONS IN FOREIGN LANGUAGES
FIGURES
Fig. 1 Front view
Fig. 2 Rear view
Fig. 3 PM 9540/TWE, SMD Tweezers
Fig. 4 PM 9540/BAN, 4-wire test cable with banana plugs
Fig. 5 PM 9541 A, 4-wire test cable
Fig. 6 Single and double test posts
Fig. 7 PM 9542SMD, SMD Adapter
Fig. 8 PM 9542A, RCL Adapter
SERVICE CENTERS
Pliki:
918
Pobrania w zeszłym miesiącu:
9
Pobierz
fluke--pm-6303a--user--ID10173.pdf
Katalog
Typ ręczny:
Katalog
Strony:
5
Rozmiar:
81,4 KB
Język:
angielski
Poprawka:
Manual-ID:
Data:
1998
Jakość:
Dokument elektroniczny, bez skanu, bardzo dobrze czytelny.
Data przesłania:
21 stycznia 2023
MD5:
b17e53de-4eb3-f354-7d14-e8a3e6897cdd
Pliki:
850
Pobrania w zeszłym miesiącu:
34
Pobierz
fluke--pm-6303a--datasheet--ID13898.pdf