opweb.de

Bezpłatne archiwum podręczników i instrukcji serwisowych podręczniki


Czego szukasz?


Fluke - 8040A - Multimetr cyfrowy
Producent:
Wyposażenie:
8040A
Data:
1976
Kategoria:
Grupa:
Podgrupa:

Informacja

The Model 8040A Multimeter provides the accuracy and portability required in today’s field service work. A slide-out sunshade protects the 4/2 digit LED display from glare when operating the 8040A in adverse lighting conditions. The small size and battery power add to the portability; yet the fold-away stand allows the instrument to be positioned at a convenient angle for bench top use. The 8040A offers 20,000 count resolution in all five functions which provides measurement resolution to 0.01 ohms on the 200 ohm range and 10 microvolts on the 200 millivolt range. AC voltage and current measurements are made using true rms conversion techniques for improved accuracy in communications and industrial control applications. Several Accessories are available for use with the 8040A to expand its’ capabilities. A list of these Accessories is provided in Table l-1 while more detail about each one is provided in Section 6. Note that two of the Accessories the 80T-150 temperature Probe and A8l battery charger/eliminator, are configured at the factory for particular applications. Insure that the correct form of the model number is used when ordering either of these Accessories

pokaż więcej

1 podręcznik

Instrukcja obsługi i użytkowania
Typ ręczny:
Instrukcja obsługi i użytkowania
Strony:
61
Rozmiar:
6,5 MB
Język:
angielski
Poprawka:
Manual-ID:
427138
Data:
Październik 1976
Jakość:
Zeskanowany dokument, wszystko czytelne.
Data przesłania:
20 stycznia 2018
MD5:
3e631fa2-036c-f674-0e97-99e3974ee242

Informacja

1 INTRODUCTION AND SPECIFICATIONS... 1-1. INTRODUCTION... 1-6. SPECIFICATIONS... 2 OPERATING INSTRUCTIONS ... 2-1. INTRODUCTION... 2-3. SHIPPING INFORMATION... 2-6. INPUT POWER... 2-8. OPERATING FEATURES... 2-10. OPERATING NOTES... 2-12. Fuse Replacement... 2-14. Overrange Indication ... 2-16. Input Overload Protection/l ... 2-18. ASSEMBLY AND INITIAL OPERATION... 2-22. FUNCTION SELECTION EXAMPLES... 3 THEORY OF OPERATION... 3-1. INTRODUCTION... 3-3. OVERALL FUNCTIONAL DESCRIPTION... 3-4. Introduction... 3-6. Analog Circuits... 3-8. Digital Circuits... 3-10. CIRCUIT DESCRIPTION... 3-11. Introduction... 3-13. Input Divider... 3-15. Current Shunts... 3-17. Buffer... 3-19. A/D Reference... 3-26. Ohms Voltage Source 3-28. RMS Converter 3-33. A/D Converter 3-35. Timing and Control... 3-38. Display... 4 MAINTENANCE... 4-1. INTRODUCTION... 4-4. GENERAL MAINTENANCE... 4-5. Access Information... 4-7. Cleaning... 4-9. Fuse Replacement... 4-11. PERFORMANCE CHECK ... 4-13. DC Volts... 4-15. AC Volts... 4-17. Resistance Measurements... 4-19. Direct Current... 4-21. Alternating Current... 4-23. CALIBRATION... 4-26. Required Method for Votlage Source Connection... 4-29. TROUBLESHOOTING ... 5 LIST OF REPLACEABLE PARTS... 5-1. INTRODUCTION... 5-4. HOW TO OBTAIN PARTS ... 5-7. USE CODE EFFECTIVITY LIST... 6 OPTIONS & ACCESSORY INFORMATION... 6-1. INTRODUCTION... 6-3. RECHARGEABLE BATTERY PACK 8040A 7005... 6-4. Introduction... 6-6. Operation... 6-8. BATTERY COVER KIT 8040A 7004 ... 6-10. BATTERY COVER 8040A 7007 ... 6-12. CARRYING CASE (C88)... 6-14. BATTERY CHARGER/ELIMINATOR... 6-16. TEMPERATURE Probe (80T-150)... 6-17. Introduction... 6-20. Operating Notes... 6-25. Operating Instructions... 6-27. DELUXE TEST LEAD KIT(A80)... 6-29. CURRENT TRANSFORMER, CLAMP-ON (801-600)... 6-30. Introduction... 6-32. Operation... 6-34. HIGH VOLTAGE Probe (80F-5) ... 6-35. Introduction... 6-39. Cleaning... 6-41. Calibration... 6-44. HIGH VOLTAGE Probe (80F-15) ... 6-45. Introduction... 6-49. Cleaning... 6-51. Calibration... 6-54. HIGH VOLTAGE Probe 80K-40 6-55. Introduction... 6-58. HIGH FREQUENCY Probe (81RF)... 6-59. Introduction... 6-61. HIGH FREQUENCY Probe 82RF 6-62. Introduction...

pokaż więcej

Pliki:
982
Pobrania w zeszłym miesiącu:
10
Pobierz fluke--8040a--service-user--ID10165.pdf