opweb.de

Bezpłatne archiwum podręczników i instrukcji serwisowych podręczniki


Czego szukasz?


Fluke - 78 - Multimetr cyfrowy
Producent:
Wyposażenie:
78
Data:
1998
Kategoria:
Grupa:
Podgrupa:

Informacja

Maximum Voltage Between any Terminal and Earth Ground 300 V Fuse Protection 15 A 600 V FAST Fuse Display Digital: 4000 counts, updates 4/s Bar Graph: 64 segments, update rate 40/s Frequency: 9,999 counts, updates 3/s Operating Temperature 0°C to 55°C (32°F to 131°F) Storage Temperature 40°C to 60°C (40°F to 140°F) Temperature Coefficient 0.1 x (specified accuracy) per °C ambient (<18°C or >28°C). Temperature, 0.04% + 0.1°C per °C Relative Humidity 0% to 95%, to 30°C (86°F) 0% to 75%, to 40°C (104°F) 0% to 45%, to 55°C (131°F) Altitude Electromagnetic Compatibility 2000 meters maximum In an RF field of 1 V/m on all ranges and functions: Total Accuracy = Specified Accuracy +0.7% or range Performance above 1 V/m is not specified. Battery Type 9 V, NEDA 1604 or 6F22 or 006P Battery Life Alkaline: 500 hrs (typical) Carbonzinc: 300 hrs (typical) Continuity Beeper 4096 Hz Shock, Vibration Per MILT28800E for a Type III, Class 3 Style D, Instrument Size (HxWxL) 1.12 in x 2.95 in x 6.55 in (2.8 cm x 7.5 cm x 16.6 cm) Weight 12 oz (340g) Safety Complies with EN 610101:1993, ANSI/ISA S82.011994 and CAN/CSA C22.2 No. 1010.192 Overvoltage Category II. Safety Approvals CSA Certified, TUV Product Service licensed, UL EMI Regulation Complies with FCC Part 15, Class B, VDE 0871B, Vfg. 2431991 Inductive Pickup Input: Magnetic field from spark plug Output: Pulse to trigger Fluke 78 Thermocouple Type: K (Chromel vs. Alumel) (Fluke 80PK1) Not suitable for immersion in liquid. Accuracy: ±1.1°C (2°F) between 0°C to 260°C (32°F-500°F). Typically within 1.1°C (2°F) of NBS tables for temperatures between 40°C (40°F) to 0°C (32°F). Temperature Range: 40°C to 260°C. (40°F to 500°F). Above 260°C (500°F), toxic gas might be emitted. NOTE: The temperature range is primarily a function of the thermal limitations of the thermocouple's insulation. Cable Insulation: Teflon MIN MAX Recording Accuracy: Specified accuracy of measurement function ±16 digits for changes > 200 ms in duration (±52 digits in 400 J). Nominal response time (5 to 100% of range) 100 ms to 80%

pokaż więcej

1 podręcznik

Instrukcja serwisowa
Typ ręczny:
Instrukcja serwisowa
Strony:
64
Rozmiar:
2,3 MB
Język:
angielski
Poprawka:
Manual-ID:
PN 666617
Data:
Jakość:
Dokument elektroniczny, bez skanu, bardzo dobrze czytelny.
Data przesłania:
30 listopada 2014
MD5:
d1f41610-2be2-6021-2595-0960076ae66b
Pliki:
924