Model 305 Phasemeter (figure 1-1) represents a totally
new concept in the measurement of phase angle. A precision
phase angle measurement is obtained simply by connecting the
signals and reading the display. No adjustments are required
during normal use. Model 305 senses the signal frequency and
adjusts its output time constant for maximum speed
commensurate with low ripple. It remains operational in the
presence of up to 10% high frequency noise. Model 305 sensitivity to waveform distortion is reduced over that of
other phasemeters which normally require Filter to remove
distortion effects.
1-5. The use of the automatic dual mode switching allows for
continuous phase plotting between <-160° to > +340° with no
discontinuities. The front panel controls on Model 305 main
frame are used only for self checking of the main frame and
calibration of remotely connected Accessories uch as a
recorder or printer.
1-6 . Standard Plug-In units covering a frequency range
of 1 Hz to 11 MHz are available with Model 305 Phasemeter.
Special Plug-In units are available on request.
1-7. SPECIAL FEATURES
1-8. Model 305 provides special features when used with Plug-In Model 305 PA-3001 or 305 PA-3002.
a. No operating controls.
b. Excellent stability -~ no operating adjustments.
c. 0.05° accuracy independent of input voltage.
d. Versatile Plug-In concept.
e. Basic frequency range: 2 Hz to 700 kHz (extendable to I
Hz or 11 MHz with other Plug-In ).
f. Digital readouts on Models 305B 305C and 305D g. Digital outputs on Models 305B 305C and 3&5D-for use
with printers, etc.
h. 1 Megohm input impedance.
i. Levels extendable to 40 KV using Tektronix Probe j. Indicator lights on each input to indicate either low or
high input levels 305-PA-3001 only).
k. High overvoltage capability.
1 podręcznik
Instrukcja obsługi i użytkowania
Typ ręczny:
Instrukcja obsługi i użytkowania
Strony:
174
Rozmiar:
6,3 MB
Język:
angielski
Poprawka:
Manual-ID:
TM-101378A
Data:
Jakość:
Zeskanowany dokument, odczyt częściowo zły, częściowo nieczytelny.
Data przesłania:
11 sierpnia 2017
MD5:
dca724b8-00cf-8bea-21ca-6b720496f6ac
Informacja
X GENERAL INFORMATION 1-1
1-1 Introduction 1-1
1-3 Purpose 1-1
1-7 Special Features 1-1
1-9 Equipment Characteristics and
Series 305 Configuration 1-2
II OPERATION 2-1
2-1 General 2-1 2-3 Controls, Connectors and Indicators
2-1 2-5 Unpacking 2-1 2-7 Operation 2-1 2-10 Main Frame Rear
Connectors Terminal
Designations 2-2
2-12 Operation of model 305 With Option 107 2-11 2-15
Additional Operating Features of
Model 305D 2-12
2-17 Operation 2-12
III PERFORMANCE CHECK 3-1
3-1 General 3-1
3-3 Test Equipment Required 3-1
3-5 Main Frame Calibration 3-1
3-6 Minimum Performance Check 3-4
3-11 Field Installation of 305 Series Plug-In 3-7
IY THEORY OF OPERATION 4-1
4-1 General 4-1
4-3 Basic Operation of 360 Zero Crossing
Phase Meters' 4-1
4-9 Block Diagram Discussion 4-2
Y MAINTENANCE 5-1
5-1 General 5-1 5-6 Mechanical Disassembly Procedure 5-2 5-8
Circuit Description 5-5 5-10 model 305 PA-3001 Wide Range Plug-In 5-5 5-36 model 305 Main Frame Control Circuits 5-9
5-49 Model 305D Offset and Null Circuits 5-11 5-54 Series
305 Dual Power Supply 5-11 5-61 Selected Components 5-13
6-1 General
6-4 Equipment Required
6-5 Equipment Setup
6-6 Test Procedure
6-9 Adjustment Procedure for Option 107
6-11 (Card All) Adjustment Procedure for 305D Offset
6-13 Circuits Adjustment Procedure (Model 305-PA-3001 6-20 In Main Frame) Adjustment Procedure (Model 305~PA-3002
In Main Frame) REPLACEABLE PARTS LIST
7-1 General
AVAILABLE OPTIONS
8-1 General
8-3 Option 101
8-6 Option 102
8-10 Remote Operation
8-18 Additional Operating Control Infor-
8-21 mation for Remote Operation of Automatic Calibration
When Option 107 is Used Option 103
8-28 Option 105
8-31 Option 107