Xantrex XPL 56-1 Zasilanie
Producent:
Brak zdjęcia!
Może możesz przesłać zdjęcie za
Xantrex XPL 56-1 ?
Jeśli masz jakieś inne podręczniki dla
Xantrex XPL 56-1, możesz przesłać pliki tutaj .
Model:
XPL 56-1
Data:
2007
Kategoria:
Grupa:
Opis:
Linear DC Power Supply
Informacja
The XPL series provides medium levels of power (up to 125 watts) in a compact and attractive case style using linear regulation.
High resolution controls allow precise setting of voltage and current levels which are indicated on accurate and highly legible digital meters.
Excellent line and load regulation is matched by very low noise and good transient response. Improved power efficiency ensures that the units require no fan cooling.
The XPL 30-2D has two independent isolated outputs each with a 0 to 30V, 0 to 2A capability. The outputs operate in constant voltage or constant current mode with automatic crossover and mode indication. Each output has its own on-off switch. The outputs can be wired in either series or parallel to provide voltages up to 60 volts or currents up to 4 amps. The XPL 30-2T has, in addition, an Auxiliary ‘logic voltage’ output with a 2A current capability. This output can be preset between 1.5 volts and 5 volts via a front panel control.
The XPL 18-3
XPL 30-1
XPL 30-2 and XPL 56-1 are single output supplies capable of supplying up to 15V/5A, 18V/3.3A, 30V/1A, 30V/2A, 30V/3A or 56V/1.1A respectively.
The XPL series incorporates separate digital voltage and current meters on each output. The meters use bright 14mm (0.56”) LED displays and have an update rate of 4 per second providing near instantaneous response. Simultaneous metering of voltage and current provides accurate information “at a glance” and avoids any possibility of misinterpretation. When an output switch is set to “off”, the current limit setting is displayed enabling conditions to be set before the load is connected. With the right-hand main output off the right-hand meters can be used to momentarily display the preset Auxiliary voltage and current limit.
The XPL series has been designed to meet the stringent requirements of relevant IEC standards for safety and EMC. All outputs are intrinsically short circuit proof, and are protected against external voltages and reverse currents.
Typ ręczny:
Instrukcja obsługi
Strony:
36
Rozmiar:
627.69 Kbytes (642754 Bytes)
Język:
english, german, french, italian
Rewizja:
Ręczny ID:
48511-0980 and/or 975-0100-01-05
Data:
Jakość:
Dokument elektroniczny, bez skanowania, bardzo dobrze czytelne.
Data przesłania:
2013 11 03
MD5:
af78d060c4320135ae0102a2250af381
Pobrane:
2970
Informacja
Introduction 2
Specification 3
EMC 5
Safety 6
Installation 7
Operation - Main Outputs 8
Operation – Auxiliary Output 9
Operation - General 9
Calibration 10
Maintenance 11
Instructions en Francais 12
Bedienungsanleitung auf Deutsch 17
Istruzioni in Italiano 22
Instrucciones en Español 27
Warranty Information 32