Tektronix TDS 460A Oscyloskop
Producent:
Model:
TDS 460A
Data:
1995
Kategoria:
Grupa:
Opis:
Digitizing Oscilloscope

Informacja

Your Tektronix digitizing Oscilloscope is a superb tool for acquiring, displaying, and measuring waveforms. Its performance addresses the needs of both lab and portable applications with the following features: 400 MHz maximum analog bandwidth on the TDS 460A 200 MHz maximum analog bandwidth on the TDS 410A and TDS 420A 100 Megasamples/second maximum digitizing rate Roll mode and triggered roll mode for display of slower waveforms Waveform Math — Invert a single waveform and add, subtract, and multiply two waveforms. On instruments equipped with option 2F, integrate or differentiate a single waveform or perform an FFT (fast fourier transform) on a waveform to display its magnitude or phase versus its frequency. Up to 30,000-point record length per channel (120,000-point optional) Full GPIB Software programmability. GPIB hardcopy output. On instruments equipped with option 13, hardcopy output using the RS-232 or Centronics ports. On-board printer capability with option 3P instruments. Complete measurement and documentation ability Intuitive graphical icon operation blended with the familiarity of traditional horizontal and vertical knobs Four channels and four eight-bit digitizers on TDS 420A and TDS 460A, Two channels and two eight-bit digitizers on TDS 410A, On-line help at the touch of a button

pokaż więcej

Instrukcja obsługi
Typ ręczny:
Instrukcja obsługi
Strony:
433
Rozmiar:
2.36 Mbytes (2474165 Bytes)
Język:
english
Rewizja:
Ręczny ID:
070-9876-00
Data:
Jakość:
Dokument elektroniczny, bez skanowania, bardzo dobrze czytelne.
Data przesłania:
2019 09 17
MD5:
0946a08d5cd2969aa61a8b1d7be713c2
Pobrane:
3267

Informacja

Programmer Manual Overview of the Manual ... . Setting Up Remote Communications ... . Command Syntax ... . Command and Query Structure ... . Clearing the TDS Family Oscilloscope ... . Command Entry ... . Constructed Mnemonics ... . Argument Types ... . Syntax Diagrams ... . Command Groups ... . Acquisition Commands ... . Alias Commands ... . Application Menu Commands ... . Calibration and Diagnostic Commands ... . Cursor Commands ... . Display Commands ... . File System Commands ... . Hardcopy Commands ... . Histogram Commands ... . Horizontal Commands ... . Limit Test Commands ... . Mask Commands ... . Measurement Commands ... . Miscellaneous Commands ... . RS-232 Commands ... . Save and Recall Commands ... . Status and Error Commands ... . Trigger Commands ... . Vertical Commands ... . Waveform Commands ... . Zoom Commands ... . Command Descriptions ... . Registers ... . Queues ... . Event Handling Sequence ... . Synchronization Methods ... . Messages ... .Compiling the Example Programs ... . Appendices Appendix A: Character Charts ... . Appendix B: Reserved Words ... . Appendix C: Interface Specifications ... . GPIB Function Subsets ... . Interface Messages ... . Appendix D: Factory Initialization Settings ... . Glossary and Index

pokaż więcej

Instrukcja obsługi
Typ ręczny:
Instrukcja obsługi
Strony:
433
Rozmiar:
2.36 Mbytes (2474180 Bytes)
Język:
english
Rewizja:
Ręczny ID:
070-9876-00
Data:
Jakość:
Dokument elektroniczny, bez skanowania, bardzo dobrze czytelne.
Data przesłania:
2017 04 15
MD5:
39db048a34ae4f74d557bf84de9eaebc
Pobrane:
5549

Informacja

Programmer Manual This programmer manual covers the TDS 420A 430A, 460A, 510A, 520C, 540C, 620B, 644B, 680B, 684B, 724C, 754C, & 784C. It also covers Advanced DSP Math (optional on the TDS420A, 430A, 460A, 510A, 520C, 540C, 620B, & 680B), the RS-232/Centronics Interface (optional on the TDS 420A, 430A, 460A, 510A, 520C, 540C, 620B, & 640B), and the Option 05 Video Trigger. This manual provides information on operating your Oscilloscope using the General Purpose Interface Bus (GPIB) Interface.

pokaż więcej

Dane techniczne
Typ ręczny:
Dane techniczne
Strony:
4
Rozmiar:
67.16 Kbytes (68773 Bytes)
Język:
english
Rewizja:
Ręczny ID:
3GW-10375-4
Data:
1998 01 01
Jakość:
Dokument elektroniczny, bez skanowania, bardzo dobrze czytelne.
Data przesłania:
2017 12 28
MD5:
4fe59168c5416edffe78b0fb554b0c0a
Pobrane:
1458

Informacja

pokaż więcej

Instrukcja serwisowa
Typ ręczny:
Instrukcja serwisowa
Strony:
288
Rozmiar:
4.16 Mbytes (4357039 Bytes)
Język:
english
Rewizja:
A
Ręczny ID:
070-9703-06
Data:
Jakość:
Dokument elektroniczny, bez skanowania, bardzo dobrze czytelne.
Data przesłania:
2020 07 26
MD5:
6675f02056d5324c605ef78f80381ca1
Pobrane:
874

Informacja

S/N B080000 and above List of Figures ... iii List of Tables ... vi General Safety Summary ... ix Service Safety Summary ... xi Preface ... xiii Introduction ... xvi Before Servicing ... xvi Strategy for Servicing ... xvi Tektronix Service ... xvii Specifications Product Description ... 1-1 Nominal Traits ... 1-7 Warranted Characteristics ... 1-15 Typical Characteristics ... 1-23 Operating Information Installation ... 2-1 Supplying Operating Power ... 2-1 Operating Environment ... 2-3 Applying and Interrupting Power ... 2-4 Repackaging Instructions ... 2-5 Installed Options ... 2-5 Operating Information ... 2-7 Screen Layout ... 2-7 Basic Procedures ... 2-7 Theory of Operation Theory of Operation ... 3-1 Logic Conventions ... 3-1 Module Overview ... 3-1 Performance Verification Performance Verification Procedures ... 4-1 Brief Procedures ... 4-5 Self Tests ... 4-5 Functional Tests ... 4-7 Performance Tests ... 4-15 Prerequisites ... 4-15 Equipment Required ... 4-16 Test Record ... 4-18 Signal Acquisition System Checks ... 4-20 Time Base System Checks ... 4-34 Trigger System Checks ... 4-38 Output Signal Check ... 4-53 Sine Wave Generator Leveling Procedure ... 4-55 Adjustment Procedures Adjustment Procedures ... 5-1 Requirements for Performance ... 5-1 Usage ... 5-2 Equipment Required ... 5-5 Adjustment Instructions ... 5-7 Probe Adjustment ... 5-10 Monitor Assembly Adjustment ... 5-21 Maintenance Maintenance ... 6-1 Related Maintenance Procedures ... 6-1 Preparation ... 6-2 Inspection and Cleaning ... 6-4 Removal and Installation Procedures ... 6-9 Preparation — Please Read ... 6-9 Access Procedure ... 6-13 Procedures for Module Removal and Installation ... 6-23 Disassembly for Cleaning ... 6-71 Troubleshooting ... 6-75 Diagnostics ... 6-75 Firmware Updates ... 6-76 Troubleshooting Equipment ... 6-77 Options Electrical Parts List Diagrams Mechanical Parts List

pokaż więcej

Instrukcja obsługi
Typ ręczny:
Instrukcja obsługi
Strony:
292
Rozmiar:
2.44 Mbytes (2558950 Bytes)
Język:
english
Rewizja:
Ręczny ID:
070-9219-00
Data:
Jakość:
Dokument elektroniczny, bez skanowania, bardzo dobrze czytelne.
Data przesłania:
2013 04 25
MD5:
78eadd99bad5ddff7758019af5eaf57b
Pobrane:
2399

Informacja

Table of Contents List of Figures ... iii List of Tables ... vii General Safety Summary ... ix Preface ... xi Getting Started Product Description ... 1–1 Start Up ... 1–3 Operating Basics Functional Overview ... 2–1 At a Glance ... 2–3 Tutorial ... 2–13 Reference Overview ... 3–1 Accessing Help ... 3–3 Acquisition Modes ... 3–5 Delayed Triggering ... 3–13 Determining Status ... 3–19 Display Modes ... 3–21 Edge Triggering ... 3–27 File System ... 3–31 Hardcopy ... 3–35 Horizontal Control ... 3–45 Limit Testing ... 3–53 Measuring Waveforms ... 3–59 Probe Accessories ... 3–71 Probe Compensation ... 3–81 Probe Selection ... 3–83 Remote Communication ... 3–89 Roll Mode ... 3–93 Saving and Recalling Setups ... 3–97 Saving and Recalling Waveforms ... 3–101 Selecting Channels ... 3–107 Setting Up Automatically: Autoset and Reset ... 3–111 Signal Path Compensation ... 3–113 Taking Cursor Measurements ... 3–115 Vertical Control ... 3–121 Video Triggering ... 3–125 Waveform Math ... 3–131 Zoom ... 3–135 Appendices Appendix A: Options and Accessories ... A–1 Appendix B: Specification ... B–1 Appendix C: Algorithms ... C–1 Appendix D: Packaging for Shipment ... D–1 Appendix E: Factory Initialization Settings ... E–1 Appendix F: Remote Display ... F–1

pokaż więcej

Instrukcja serwisowa
Typ ręczny:
Instrukcja serwisowa
Strony:
288
Rozmiar:
4.16 Mbytes (4358985 Bytes)
Język:
english
Rewizja:
Ręczny ID:
070-9703-06
Data:
Jakość:
Dokument elektroniczny, bez skanowania, bardzo dobrze czytelne.
Data przesłania:
2011 06 18
MD5:
9fb3d32a15acdf10d081115219475c1e
Pobrane:
3338

Informacja

This document applies to instruments with serial numbers B050000 and above.

pokaż więcej

Instrukcja obsługi
Typ ręczny:
Instrukcja obsługi
Strony:
94
Rozmiar:
444.69 Kbytes (455362 Bytes)
Język:
english
Rewizja:
Ręczny ID:
070-9705-02
Data:
Jakość:
Dokument elektroniczny, bez skanowania, bardzo dobrze czytelne.
Data przesłania:
2019 09 16
MD5:
aca49b86d0feaba3a4f6d5035756787f
Pobrane:
1040

Informacja

Performance Verification and Specifications General Safety Summary ... . Preface ... . Performance Verification Specifications Performance Verification Procedures ... . Brief Procedures ... . Self Tests ... . Functional Tests ... . Performance Tests ... . Prerequisites ... . Equipment Required ... . Test Record ... . Signal Acquisition System Checks ... . Time Base System Checks ... . Trigger System Checks ... . Output Signal Check ... . Sine Wave Generator Leveling Procedure ... . Specification ... . Nominal Traits ... . Warranted Characteristics ... . Typical Characteristics ... .

pokaż więcej

Instrukcja obsługi
Typ ręczny:
Instrukcja obsługi
Strony:
6
Rozmiar:
545.10 Kbytes (558178 Bytes)
Język:
english
Rewizja:
Ręczny ID:
070-9220-00
Data:
Jakość:
Dokument elektroniczny, bez skanowania, bardzo dobrze czytelne.
Data przesłania:
2017 12 27
MD5:
c30e2a84f0e379d562791196eac8d7f8
Pobrane:
1357

Informacja

Quick Reference

pokaż więcej

Instrukcja obsługi
Typ ręczny:
Instrukcja obsługi
Strony:
94
Rozmiar:
460.00 Kbytes (471036 Bytes)
Język:
english
Rewizja:
Ręczny ID:
070-9218-00
Data:
1995 01 01
Jakość:
Dokument elektroniczny, bez skanowania, bardzo dobrze czytelne.
Data przesłania:
2017 12 27
MD5:
ca8463ec132c1b0ec37db268fc37c8e6
Pobrane:
1931

Informacja

Performance Verification and Specifications This is the Performance Verification for the TDS 410A TDS 420A, and TDS 460A Oscilloscopes. It contains procedures suitable for determining if the Oscilloscope functions, is adjusted properly, and meets the performance characteristics as warranted. Also contained in this document are the specifications for the TDS 400A Digitizing Oscilloscopes.

pokaż więcej

Instrukcja serwisowa
Typ ręczny:
Instrukcja serwisowa
Strony:
286
Rozmiar:
3.28 Mbytes (3437968 Bytes)
Język:
english
Rewizja:
Ręczny ID:
070-9703-04
Data:
Jakość:
Dokument elektroniczny, bez skanowania, bardzo dobrze czytelne.
Data przesłania:
2019 09 16
MD5:
f661167c8bc131bfe67ea4a7ebae9368
Pobrane:
1160

Informacja

This document applies to instruments with serial numbers B050000 and above. This manual is divided into Chapters such as Specifications and Theory of Operation. Further, it is divided into subsections such as Product Description and Removal and Installation Procedures. Sections containing procedures also contain introductions to those procedures. Be sure to read these introductions because they provide information needed to do the service correctly and efficiently. A brief description of each manual chapter follows: Specifications contains a product description of the digitizing Oscilloscope and tables of the characteristics and descriptions that apply to it. Operating Information is this chapter. It includes a description of how this manual is structured as well as general information and operating instructions at the level needed to safely power on and service this Oscilloscope. A statement of the service strategy that this manual supports and instructions for shipment of the digitizing Oscilloscope are found in this chapter. Theory of Operation contains circuit descriptions that support general service and fault isolation. Performance Verification contains a collection of procedures for confirming that this digitizing Oscilloscope functions properly and meets warranted limits. Adjustment Procedures contains a collection of procedures for adjusting this digitizing Oscilloscope to meet warranted limits. Maintenance contains information and procedures for doing preventive and corrective maintenance of the digitizing Oscilloscope. Instructions for cleaning, for module removal and installation, and for fault isolation to a module are found here. Options contains information on the factory-installed options that may be present in your Oscilloscope. Electrical Parts List contains a statement referring you to the Mechanical Parts List, where both electrical and mechanical modules are listed. See below. Diagrams contains a block diagram and an interconnection diagram useful for isolating failed modules. Mechanical Parts List includes a table of all replaceable modules, their descriptions, and their Tektronix part numbers.

pokaż więcej