Informacji Wyposażenie:

Laerdal Heartstart 911 Defibrylator
Producent:
Laerdal
Model: Heartstart 911
Data:
Kategoria: Wyposażenie medyczne i biomedyczne
Grupa: Defibrylator
Opis:
Informacje:
                                    The Heartstart 911 is a lightweight, portable,
battery-powered, semi-automatic Defibrillator. When
connected to a patient via cables and self-adhesive
defibrillation Electrodes and turned on, the Heartstart 911
prompts the operator to take specific actions, analyses the
ECG, charges the shock capacitors and indicates whether a
shockable rhythm is present. The operator discharges the device.

The Heartstart 911 is intended for use by emergency care
personnel who have completed training and certification
requirements applicable to the use of a Defibrillator. It is
specifically designed for use in early defibrillation
programme with medically approved patient-care protocols.

The recognition of a shockable arrhythmia, ventricular
fibrillation, (or rapid ventricular tachycardia), is based
on the Heartstart 911 ’s ECG analysis system.

ECG signals are acquired via two disposable, defibrillation
electrodes. Contact between the Electrodes and the patient
is monitored to ensure proper electrode contact. Discharge
energy levels of 200, and 360 joules are available.

Power is provided from an easily exchanged, rechargeable,
sealed lead-acid battery installed in the side of the
Heartstart 911.

For further battery maintenance details see page 22.

If the Heartstart 911 is being charged with a Heartstart
battery charger, an automatic device selftest can be
performed at regular intervals.

Device status, warnings, and operating messages are
presented on a two-line display. Three pushbuttons are used
to operate the device. Voice messages or “prompts” reinforce
important displayed messages.

Internal memory in the Heartstart 911 records information
about device operation and stores up to 150 seconds of a
patient's ECG that can be downloaded to a Medical Control
Module Plus. The Medical Control Module Plus can store up to
20 minutes of a patient's ECG in its memory for later
printing of a report. Printing is performed by separate
equipment.

Te Podręczniki są dostępne dla powyższego urządzenia:

Instrukcja obsługi Typ: Instrukcja obsługi Laerdal-10632-Manual-Page-1-Picture
Strony: 34
Rozmiar: 1.53 Mbytes (1608965 Bytes)
Język: Angielski
Weryfikacja: A
Manual-ID/Number: IDK 2277
Data:
Jakość: Skanowany dokument, wszystko czytelne.
Czas trwania filmu:
MD5: af6dc7fe9c387ccb9e6f7fd372a13a1d
Pliki do pobrania: 42 od 30 marzec 2018
Informacje:
Technical Manual and Curcuit diagramm

.0	GENERAL
.0	TECHNICAL SPECIFICATIONS
2.1	Physical Properties
2.1.1	Environmental
2.1.2	Expected Life and Maintenance
2.2.1	Electrodes
2.2.2	Patient Cable
2.2.3	ECG-Amplifier
2.2.4	Electrode Connection Measurement
2.2.5	ECG Rhythm Recognition Detector
2.3 / 2.4 Defibrillation Circuit	
2.5.1	Main Microcontroller
2.5.2	Program Memory
2.5.3	Data Memory
2.5.4	Reset Circuit
2.5.5	Serial Communication format
2.5.6	Real Time Clock Calendar
2.5.7	Speech Circuit
2.5.8	Beeper
2.6.1	l/O-Microcontroller
2.6.2	Temperature Measurement
2.6.3	Break Detect on Receive Signal
2.6.4	Power Reset
2.7	Power Supply
2.7.1	Battery (new and fully charged)
2.7.2	Battery Charger
2.7.3	Non-lsolated Section of the Power Supply
2.7.4	Isolated Section of the Power Supply
2.8	Operation
2.8.2	Display
2.9	Warning and Error Identifiers
2.9.1	Error Detection and Handling
2.9.2	Automatic Power Off
2.10	Automatic Self tests
2.10.1	Testload
.0	FUNCTIONAL DESCRIPTION
3.1	System Overview
3.2.1	Electrode Detection System
3.2.2	ECG Amplifier
3.3	High Voltage Charging Circuit ^
3.4	High Voltage Discharge Circuit
3.5	Main Microcontroller Functions
3.6	l/O-Microcontroller Functions
3.7	Power Supply
3.8	Tape Deck
.0	SERVICE AND MAINTENANCE
4.1	Unit Reprogramming
4.1.1	Equipment
4.2	Calibration
4.2.1	Equipment
4.2.1	Calibration Procedure
4.3	After Service Test
4.3.1	Test Equipment
4.3.2	Test Procedure
i.O	Mechanical Construction/Parts list
.0	Schematics
Laerdal-10632-Manual-Page-1-Picture


Instrukcja obsługi Typ: Instrukcja serwisowa Laerdal-10633-Manual-Page-1-Picture
Strony: 55
Rozmiar: 1.93 Mbytes (2023871 Bytes)
Język: Angielski
Weryfikacja:
Manual-ID/Number:
Data:
Jakość: Skanowany dokument, wszystko czytelne.
Czas trwania filmu:
MD5: a855811a8bada9b6b7535f20dbba51ce
Pliki do pobrania: 38 od 30 marzec 2018
Informacje:
Technical Manual and Curcuit diagramm

.0	GENERAL
.0	TECHNICAL SPECIFICATIONS
2.1	Physical Properties
2.1.1	Environmental
2.1.2	Expected Life and Maintenance
2.2.1	Electrodes
2.2.2	Patient Cable
2.2.3	ECG-Amplifier
2.2.4	Electrode Connection Measurement
2.2.5	ECG Rhythm Recognition Detector
2.3 / 2.4 Defibrillation Circuit	
2.5.1	Main Microcontroller
2.5.2	Program Memory
2.5.3	Data Memory
2.5.4	Reset Circuit
2.5.5	Serial Communication format
2.5.6	Real Time Clock Calendar
2.5.7	Speech Circuit
2.5.8	Beeper
2.6.1	l/O-Microcontroller
2.6.2	Temperature Measurement
2.6.3	Break Detect on Receive Signal
2.6.4	Power Reset
2.7	Power Supply
2.7.1	Battery (new and fully charged)
2.7.2	Battery Charger
2.7.3	Non-lsolated Section of the Power Supply
2.7.4	Isolated Section of the Power Supply
2.8	Operation
2.8.2	Display
2.9	Warning and Error Identifiers
2.9.1	Error Detection and Handling
2.9.2	Automatic Power Off
2.10	Automatic Self tests
2.10.1	Testload
.0	FUNCTIONAL DESCRIPTION
3.1	System Overview
3.2.1	Electrode Detection System
3.2.2	ECG Amplifier
3.3	High Voltage Charging Circuit ^
3.4	High Voltage Discharge Circuit
3.5	Main Microcontroller Functions
3.6	l/O-Microcontroller Functions
3.7	Power Supply
3.8	Tape Deck
.0	SERVICE AND MAINTENANCE
4.1	Unit Reprogramming
4.1.1	Equipment
4.2	Calibration
4.2.1	Equipment
4.2.1	Calibration Procedure
4.3	After Service Test
4.3.1	Test Equipment
4.3.2	Test Procedure
i.O	Mechanical Construction/Parts list
.0	Schematics
Laerdal-10633-Manual-Page-1-Picture


Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
Captcha Image
Powered by Commentics