Tektronix SD-20 Sonda
Producent:
Brak zdjęcia!
Może możesz przesłać zdjęcie za
Tektronix SD-20 ?
Jeśli masz jakieś inne podręczniki dla
Tektronix SD-20, możesz przesłać pliki tutaj .
Model:
SD-20
Data:
1993
Kategoria:
Grupa:
Opis:
Sampling Head
Informacja
The SD-20 Sampling Head is a high-performance sampling head
that can be installed in the 11800 Series Digital Sampling
Oscilloscopes, the SM-11 Multi-Channel Unit, and the CSA 803
Series Communications Signal Analyzers.
The SD-20 Sampling Head provides the following features:
■ A one-channel feed thru path for signal acquisition and
measurements.
■ A 17.5 ps acquisition rise time.
■ A 20 GHz typical bandwidth for high-speed signal capture.
■ Displayed noise is 750 |jVRMs typical without smoothing
and 350 |jVRMs typical with smoothing on.
■ Precision 3.5 mm connectors.
■ A SELECT CHANNEL button for quick trace acquisition and
selection from the sampling head front panel.
As shown in Figure 1, the SD-20 Sampling Head has a single
acquisition channel with a feed thru or loop path (labeled
LOOP on the front panel), an INPUT connector, and a FEED
THRU connector (both of these connectors are also located on
the front panel).
The strobe drive signal from the instrument controls the
timing of the strobe assertion to the Acquisition system.
Typ ręczny:
Instrukcja obsługi
Strony:
52
Rozmiar:
473.65 Kbytes (485019 Bytes)
Język:
english
Rewizja:
Ręczny ID:
070–7531–02
Data:
1993 01 01
Jakość:
Dokument elektroniczny, bez skanowania, bardzo dobrze czytelne.
Data przesłania:
2017 12 27
MD5:
59e6b834dc7034882c13d52dbf093814
Pobrane:
436
Informacja
List of
Figures ... iii
List of
Tables ... v
Introduction ... 1
Safety
... 3
Electrostatic Discharge
... 5
Connector Care
... 7
Installing the Sampling
Head ... 9
Using the Sampling Head
... 11
Connecting Signals
... 12
Button and
Light ... 13
Instrument/Sampling Head
Interaction ... 14
Smoothing
... 14
External Attenuation
... 14
Displaying a Trace
... 16
Adjusting
Parameters ... 19
Stored
Parameters ... 20
Loop
Gain ... 21
Adjusting Loop
Gain ... 22
Offset
Null ... 23
Adjusting Offset
Null ... 23
Taking TDR
Measurements ... 25
TDR Step
Generator ... 25
Operation with a Short
Circuit ... 26
Operation with a 50 Q Load
... 27
Operation with an Open Circuit
... 27
Baseline
Correction ... 28
Example: Taking TDR
Measurements ... 29
Changing Graticule Units for TDR
... 30
Other Triggering Configurations
... 33
External Generator with Pre-Trigger
Out ... 33
External Free-Running
Generator ... 34
Specifications ... 35
Glossary ... 37
Index ... 39