Apparatuur informatie:

Weinmann VENTIlogic WM 27000 Beademingsapparaat
Fabrikant:
Weinmann
Model: VENTIlogic WM 27000
Datum: 2007
Categorie: Medische en biomedische apparatuur
Groep: Beademingsapparaat
Beschrijving: Home Ventilation Unit
Informatie:
                                    The VENTImotion is a home ventilation unit for non-invasive,
non-life support ventilation of adult patients with
respiratory insufficiency in whom there is evidence of auto-
nomous respiratory drive. This corresponds to the following
clinical pictures:
•
 restrictive and obstructive ventilation disorders like
paresis of the diaphragm, OSAS, COPD
•
 disorders of the respiratory mechanism like scoliosis,
deformity of the thorax
•
 neurological, muscular and neuromuscular disorders
•
 central respiratory regulation disorders
The VENTImotion is not suitable for life-support use.
Use the unit only for the purpose described here.

Deze handboeken zijn beschikbaar voor de bovengenoemde apparatuur:

Handleidingen Type: Servicehandboek Weinmann-10579-Manual-Page-1-Picture
Pagina's: 64
Maat: 4.89 Mbytes (5124512 Bytes)
Taal: Engels
Herziening van:
Manual-ID/Number: WM 16832
Datum: 01 januari 2007
Kwaliteit: Elektronisch document, geen scan, zeer goed leesbaar.
Upload datum:
MD5: 74a984a98c2c343925bad3271a927129
Downloads: 287 Sinds 08 maart 2018
Informatie:
Introduction  ... .
. . .3
1. Overview  ... .
 ... .4
2. Description of device  ... .
. .10
2.1 Intended use for VENTImotion/VENTIlogic . 10
2.2 Functional description  ... 10
– Provision of therapy pressure
– Therapy modes
– Other functions
3. Hygiene treatment  ... .11
3.1 Cleaning and disinfecting in use ... 11
3.2 Cleaning and disinfecting on repair  ... 11
3.3 Cleaning and disinfecting for a
patient change  ... 11
3.4 Clean and disinfect humidifier during use . . 12
3.5 Clean and disinfect humidifier on patient
change  ... 12
3.6 Clean and disinfect the VENTIpower  ... 12
3.7 Clean and disinfect the VENTI-O2  ... 12
4. Test the device  ... .
. . .13
4.1 General  ... 13
4.2 Test equipment  ... 13
4.3 Preparation for testing ... 13
– Check power supply cable
– Check housing
– Connection to VENTIsupport
4.4 Enter device data  ... 14
4.5 Test temperature calibration and
calibration status  ... 14
4.6 Test battery voltage  ... 15
4.7 Test interface with the VENTIclick  ... 15
4.8 Check target pressure values
5, 20 and 35 hPa ... 15
4.9 Test flow measurement  ... 16
4.10 Test leaktightness  ... 17
4.11 Test clock function  ... 17
4.12 Test the interface with the VENTI-O2  ... 18
4.13 Test interface with the VENTIpower  ... 18
4.14 Test noise  ... 19
4.15 Test all keys, the rotary knob and
115 V mode  ... 19
4.16 Test display incl. backlighting and
contrast, the LEDs and the alarm  ... 20
4.17 Test equipment and accessories
(system components)  ... 21
– Check function of humidifier
– Function check VENTI-O2
4.18 Once tests are complete ... 22
5. Maintenance  ... .
. .23
5.1 Intervals  ... 23
5.2 Filter change ... 24
– Coarse dust filter
– Fine filter
– Reset filter change indicator
– Bacteria filter
5.3 Device cleaning  ... 25
5.4 Reset maintenance symbol ... 26
5.5 Check the maintenance sticker  ... 27
5.6 Disposal  ... 27
6. Malfunctions and rectification  ... 28
6.1 General faults ... 28
6.2 Internal faults  ... 29
– Fault output in clear text
– Coded error messages
7. Repairguide for VENTImotion/VENTIlogic  ... 31
7.1 General  ... 31
7.2 Open device  ... 31
7.3 Close the device  ... 32
7.4 Replace mains supply unit ... 33
7.5 Replace power board  ... 34
7.6 Replace box and filter holder ... 35
7.7 Replace fan  ... 37
7.8 Replace control board/display  ... 39
7.9 Replace battery on control board  ... 42
7.10 Dismantle device outlet  ... 42
7.11 Replace encoder (dial)  ... 44
7.12 Replace fascia film  ... 45
7.13 Replace bottom part of housing ... 46
7.14 Replace top part of housing  ... 47
8. Spare parts  ... 48
8.1 List of spare parts for
VENTImotion/VENTIlogic  ... 48
8.2 Spare parts required for servicing ... 51
9. Tools, test equipment and disinfectants  ... 53
9.1 Tools  ... 53
9.2 Test equipment and fixtures  ... 53
9.3 Disinfectants  ... 54
10. Technical data  ... 55
10.1 Diagram of pneumatic system  ... 57
10.2 Safety distances  ... 57
11. Technical amendments  ... 58
12. Protocols  ... .
 ... 59
12.1 Repair and service protocol  ... 59
12.2 Test protocol  ... 60
Weinmann-10579-Manual-Page-1-Picture


Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
Captcha Image
Powered by Commentics