Telecommunications Techniques Corporation FIREBERD 6000 Network Analyzer
Fabrikant:
Afbeelding 1 van 1
Als je nog andere foto's of handleidingen hebt voor de
Telecommunications Techniques Corporation FIREBERD 6000 kun je de bestanden hier uploaden .
Model:
FIREBERD 6000
Datum:
1995
Categorie:
Groep:
Omschrijving:
Communications Analyzer
Informatie
The FIREBERD 6000 (shown in Figure 1-1) is a multifunction
communications Analyzer that can terminate a variety of
communications circuits and analyze the quality of the
circuit under test. A rear panel Interface slot provides the
flexibility to access the circuit at a variety of locations.
Locations in which the FIREBERD can be used include: central
offices (COs), technical control centers, end-user sites,
engineering laboratories, and earth stations. The location
where access to the circuit can be gained determines the
Interface that is installed in the FIREBERD 6000, The
Interface provides the physical connection to the circuit
under test. The Interface also provides proper termination,
signal conditioning, framing (if required), and timing. See
Section 5 for a list of interfaces available for use with
the FIREBERD 6000, These interfaces can be divided into the
following categories:
• DDS Interfaces (DDSLL, DS0A/B, and DS0/A)
• T-Carrier Interfaces (T1/FT1, DS1/T1, T1 C/2, and T3)
• CCITT Interfaces ( 64K/G.703, 2M/n64, 2M/G.704, and 8M/G.703)
• Data Interfaces (RS-232-C, RS-449, V.35, MIL449, 449/V35,
andHSSI)
• Specialty Interfaces (ISDN, LAB, Diphase, and Access)
An optional Interface is inserted in the FIREBERD Interface
slot and then either controlled locally or remotely. This
allows the user to operate the FIREBERD locally by using the
front panel switches and controls, or remotely by using a
suitable remote controller. (Refer to Section 4 for a
description of FIREBERD remote control operation.)
With the required Interface installed, the FIREBERD can be
configured to perform in-service or out-of-service analysis
of the circuit under test. Analysis results of the circuit
under test are accumulated simultaneously and stored
internally. Accumulated results can be viewed one at a time,
with any two results displayed simultaneously on the front
panel. If desired, a variety of printouts (e.g., results
print or controls print) can be generated manually or
automatically. (Refer to Section 3 for a description of the
types of printouts available and how to generate them.)
Handleidingen type:
Gebruikershandleiding
Pagina’s:
156
Grootte:
4.47 Mbytes (4682202 Bytes)
Taal:
english
Herziening:
Handleidingen-ID:
ML12136
Datum:
1992 01 01
Kwaliteit:
Gescande document, lezen deels slecht, deels niet leesbaar.
Upload datum:
2017 01 10
MD5:
261ee87d06063034e719ca6b16da4df9
Downloads:
839
Informatie
The FIREBERD 6000 User's Guide is designed for all users of
the FIREBERD 6000 Communications Analyzer. It serves to
describe how the instrument is set up in a variety of
applications and interfaces, including:
RS-232-C/V.24 (built in)
• V.35 (Model 40202)
RS-449/V. 10, V.l 1 (Model(40200)
RS-449/530/MIL (Model(41400)
• DDS Local Loop (Mode! 4! 131)
• DDS DS0A/B (Mode! 30678)
DS1 /T 1 /D4/ESF/SLC-96 (Model 40540)
T1/FT1 (Model 41440)
DS3 (Model 41945)
CCITT G.703 64 kb/s (Model 30608)
• CCITT G.704 2048 kb/s (Model 30609)
• CCITT Fractional 2048 kb/s^Model(41800)
This document won’t tell you everything about the FIREBERD
6000; the instrument’s features and capabilities are fully
described in the FIREBERD 6000 Reference Manual. But if you
require quick access to step-by-step set-up procedures,
you’ll find the FIREBERD 6000 User's Guide a handy tool.
Handleidingen type:
Gebruikershandleiding
Pagina’s:
354
Grootte:
12.71 Mbytes (13322484 Bytes)
Taal:
english
Herziening:
L
Handleidingen-ID:
50-12120-01
Datum:
1995 01 01
Kwaliteit:
Gescand document alle leesbaar.
Upload datum:
2017 01 09
MD5:
ab97c56185921a2361d7ed77650e1781
Downloads:
789
Informatie
This Reference Manual applies to all FIREBERD 6000
Communications Analyzers incorporating Software Revision L.
1.0 GETTING STARTED 1-1
1.1 DOCUMENT/SECTION
SUMMARY ... 1-1
1.2 INSTRUMENT
OVERVIEW ... 1-1
1.3 POWER
REQUIREMENTS ... 1-2
1.4 GROUND
JUMPER ... 1-3
1.5
WARNINGS ... 1-4
1.6 OPERATING
CONVENTION ... 1-5
I ? TEst CONFIGURATION
... 1-5
1.8 INSTRUMENT
CHECKOUT ... 1-6
1.9 Interface
SELECTION ... 1-10
2.0 INSTRUMENT
DESCRIPTION ... 2-1
2.1 SECTION
SUMMARY ... 2-1
2.2 FUNCTIONAL
DESCRIPTION ... 2-1
2.3
SPECIFICATIONS ... 2-2
2.4 FRONT PANEL SWITCHES AND
INDICATORS ... 2-9
2.5 REAR
PANEL ... 2-98
2.6 PERFORMING ERROR
ANALYSIS ... 2-101
2.7 PERFORMING TIMING ANALYSIS
... 2-103
2.8 DELAY
MEASUREMENTS ... 2-105
2.9 CONTENTION
CONDITIONS ... 2-107
3.0 PRINTER INTERFACES
... 3-1
3.1
INTRODUCTION ... 3-1
3.2 PRINTOUT CONTROLS AND AUXILIARY FUNCTIONS
... 3-2
4.0 REMOTE
CONTROL ... 4-1
4.1
INTRODUCTION ... 4-1
4.2 RS-232 REMOTE CONTROL
OPERATION ... 4-1
4.3 IEEE-488 PRINTER/CONTROLLER
INTERFACE ... 4-5
4.4
CONVENTIONS ... 4-10
4.5 UNIT
CONTENTION ... 4-11
4.6 REMOTE CONTROL
COMMANDS ... 4-12
4.7 STATUS
REPORTING ... 4-90
4.8 ERROR
MESSAGES ... 4-99
5.0 OPTIONS AND
ACCESSORIES ... 5-1
5.1 SECTION SUMMARY
... 5-1
5.2 OPTIONS
... 5-1
5.3
ACCESSORIES ... 5-2
5.4 ORDERING
INFORMATION ... 5-9
This manual offers detailed information about the
Telecommunications Techniques Corporation (TTC) FIREBERD
6000 Communications Analyzer. It provides a complete
instrument reference, including a general instrument
description, operating instructions, and product specifications.
Please note that the information in this manual covers the
plastic-case FIREBERD 6000
the metal-case FIREBERD MC6000,
and the remote-control-only FIREBERD 6000R. Unless indicated
otherwise, the name FIREBERD 6000 applies to all three
mainframes.
Also note that the information in this manual applies to
FIREBERD 6000 Communications Analyzers equipped with
revision K Software. Depending on the FIREBERD 6000 hardware
configuration, all that may be required to install this
latest Software version in your FIREBERD is to remove and
replace the EPROM card in the rear panel. The current
Software revision can be determined by pressing the MENU
switch to illuminate the LED next to the AUXILIARY category.
Then press the 4 and 0 keypad keys and press the ENTER key
to display the Software version installed in your FIREBERD.
Call TTC Customer Service (1-800- 638-2049) to find out
about obtaining upgrades for your FIREBERD 6000,
Section 1 provides an overview of the FIREBERD 6000
power
requirements, line power selection, ground jumper selection,
operator warnings, operating convention, instrument
checkout, internal RS232 Interface selection, and optional
Interface installation.