Fluke 8020B Digitale multimeter
Fabrikant:
Afbeelding 1 van 1
Als je nog andere foto's of handleidingen hebt voor de
Fluke 8020B kun je de bestanden hier uploaden .
Model:
8020B
Datum:
1981
Categorie:
Groep:
Omschrijving:
Informatie
1-2. Your John Fluke Model 8020B is a pocket-size digital
multimeter that is ideally suited for application in the
field, lab, shop or home. Some of the features of your
instrument are:
• All VOM functions plus conductance and continuity (8 in
all) are included as standard.
DC Voltage - 100 μν to 1000V AC Voltage - 100 μν to 750V DC
Current - 1 μΑ to 2000 mA AC Current - 1 μΑ to 2000 mA
Resistance - 0.1 il - 20 ΜΩ Diode Test
Conductance - 0.1 ns to 200 ns and .001 ms to 2 ms (S =
Siemens = 1/Ω). Continuity - Provides an immediate audible
indication when continuity is detected.
• CONDUCTANCE - A new multimeter function that allows fast,
accurate, noise free resistance measurements up to 10,000 ΜΩ.
• A high contrast 3-1/2 digit liquid crystal display that
can be easily read from across the room. No more worries
about bent needles, parallax, etc.
• Each range has:
Full auto-polarity operation
Overrange indication
Effective protection from overloads
• Dual slope integration measurement technique to ensure
noise-free measurements.
• Long term calibration stability - 2 years. Easy
calibration - few adjustments.
• Lightweight - 369 grams (13 ounces).
• Up to 200 hours of continuous operation can be expected
from a single, inexpensive, 9V, alkaline battery (transistor
radio/calculator type).
• Low battery voltage automatically detected and displayed.
• Line operation is possible using a Model A81 Battery
Eliminator (see Section 6, Accessories).
e Protected test leads - finger guards on the probes and
shrouded contacts on the connectors discourage accidental
contact with circuit voltages.
• A full line of Accessories that extend the range and scope
of your instrument.
Handleidingen type:
Service-en gebruikershandleiding
Pagina’s:
86
Grootte:
5.69 Mbytes (5961198 Bytes)
Taal:
english
Herziening:
Handleidingen-ID:
Datum:
Kwaliteit:
Gescande document, lezen deels slecht, deels niet leesbaar.
Upload datum:
2016 02 13
MD5:
1409053d21f174f53306b4ed467212a4
Downloads:
1855
Informatie
1 INTRODUCTION AND SPECIFICATIONS 1-1
l-l. INTRODUCTION
... l-l
I-3. PREPARING FOR OPERATION
... 1-2
1-4. Unpacking
... 1-2
1-7. Battery and/or Fuse Installation/Replacement
... 1-2
1-9. PHYSICAL FEATURES
... 1-4
1-11. INITIAL CHECK-OUT PROCEDURE ... 1-4
1-13. Accessories
... 1-9
1-15. SPECIFICATIONS
... 1-9
2 OPERATING
INSTRUCTIONS ... 2-1
2-1. INTRODUCTION
... 2-1
2-3. INPUT POWER
... 2-1
2-4. Battery Life
... 2-1
2-6. Line Power Operation
... 2-1
2-8. OPERATING NOTES
... 2-1
2-10. Input Overload Protection
... 2-2
2-12. Input Connections to COMMON
... 2-3
2-14. Fuse Check
... 2-3
2-16. Fuse
Replacement ... 2-3
2-18. The Display
... 2-3
2-22. OPERATION
... 2-4
2-24. MEASUREMENT TECHNIQUES
... 2-10
2-26. AC Measurement
... 2-10
2-28. Voltage AC/DC
... 2-10
2-31. Current AC/DC
... 2-10
2-35.
Resistance ... 2-14
2-39. Continuity
... 2-15
2-42. Conductance
... 2-15
2-46. APPLICATIONS
... 2-15
2-48. Transistor Tester
... 2-17
2-53. Leakage Tester
... 2-19
3 THEORY OF OPERATION 3-1
3-1. INTRODUCTION
... 3-1
3-3. OVERALL FUNCTIONAL DESCRIPTION ... 3-1
3-8. BLOCK DIAGRAM ANALYSIS
... 3-1
3-9. A/D Converter
... 3-1
3-18. Input Signal Conditioners
... 3-6
4 MAINTENANCE
... 4-1
4-1. INTRODUCTION
... 4-1
4-3. SERVICE INFORMATION
... 4-1
4-7. GENERAL INFORMATION
... 4-2
4-8. Access Information
... 4-2
4-I7. Cleaning
... 4-5
4-19. Battery/Backup Fuse Replacement
... 4-5
4-21. PERFORMANCE TEST
... 4-6
4-23. Initial Procedure
... 4-6
4-25. Display
Test ... 4-6
4-27. Resistance Test
... 4-7
4-29. Continuity Test
... 4-7
4-31. DC Voltage Test
... 4-8
4-33. AC Voltage Test
... 4-8
4-35. DC Current Test
... 4-9
4-37. CALIBRATION
... 4-10
4-40. TROUBLESHOOTING
... 4-11
5 LIST OF REPLACEABLE PARTS
... 5-1
5-1. INTRODUCTION
... 5-1
5-4. HOW TO OBTAIN PARTS
... 5-1
6 SCHEMATIC DIAGRAMS
... 6-1
APPENDIX A
... A-I