Wavetek - 3001 - Generator
Fabrikant:
Afbeelding 1 van 1
Als je nog andere foto's of handleidingen hebt voor de
Wavetek 3001
kun je
hier uploaden.
Uitrusting:
3001
Datum:
1981
Categorie:
Groep:
Subgroep:
Informatie
INTRODUCTION
The Wavetek Models 3001 3002 are rugged, completely
solid-state Signal Generator covering the frequency range
of .001 or 1 to 520 MHz. The output can be amplitude or
frequency modulated, and the level can be set between + 13
and -137 dBm.
1.1.1 FREQUENCY CHARACTERISTICS
The frequency of the instrument is set via 6 front-panel
Lever/indicator switches which yield a resolution of 1 kHz.
in addition, remote frequency programmability is standard.
Series 3900 programmers are available to facilitate
semiautomatic or GPIB programming of both frequency and
output level.
The accuracy of the instrument is based on a
crystal-controlled Oscillator that serves as a stable
frequency reference that enables the instrument to provide
high stability signals to an accuracy of 0,001% over its
specified frequency range. This accuracy includes possible
errors due to short term drift, long term drift, incidental
FM, and variations due to line voltage changes and
temperature changes. With the FREQUENCY VERNIER out of the
CAL position, the frequency is accurate to 0.001% ±10 kHz.
The accuracy of the instrument can be improved by using the
optional External Reference input or the optional
Internal/External Reference or High Stability Internal
Reference. An Auxiliary RF Output option is also available
to drive a Counter (See Section 1.3, Options.)
1.1.2 MODULATION •
These instruments also feature both internal and external
amplitude and frequency modulation capabilities. Internal
modulation frequencies of 400 Hz and 1 kHz are standard. Sn
the FM mode of operation, peak deviations to 100 kHz are
attainable. In the AM mode, amplitude modulation to 90% is
attainable.
With the MODULATION MODE switch in the AM position and the
MODULATION FREQUENCY switch in the DC position, the output
amplitude can be varied by the MODULATION FM/AM control.
This provides a reference attenuator for variation of a
signal level around a specific point of interest. This
operation can also enable the user to obtain greater than 20
milliwatts of power over portions of the band. The frequency
can also be continuously varied with this control over a 100
kHz range.
1.1.3 OUTPUT LEVEL FREATURES
The output power is indicated on a front-pane! meter
calibrated in both dBm and VRMS. A fifteen-position, 10
dB/step Attenuator used in conjunction with an 11 dB VERNIER
control provides the user with a range of +13 dBm to -137
dBm. Two programmable attenuator options (1A and 1B), see
Section 1.3.1} are available.
The calibrated output of each instrument is leveled to
within ±0.75 dB across the complete frequency range of the
instrument.
3 Handleidingen
Datasheet
Handleidingen type:
Datasheet
Pagina's:
2
Grootte:
253,9 KB
Taal:
engels
Revisie:
Handmatig-ID:
Datum:
Kwaliteit:
Gescand document, alles leesbaar.
Upload datum:
16 november 2014
MD5 MD5:
359066be-e39b-9f35-b8c6-ae4bb373baf1
Downloads:
1393
Download
wavetek--3001--datasheet--ID6384.pdf
Service- en gebruikershandleiding
Handleidingen type:
Service- en gebruikershandleiding
Pagina's:
168
Grootte:
23,9 MB
Taal:
engels
Revisie:
Handmatig-ID:
Datum:
Kwaliteit:
Gescand document, deels slecht leesbaar, deels niet leesbaar.
Upload datum:
17 november 2014
MD5 MD5:
26f9367c-77ca-46c3-0402-f1963ef22245
Informatie
SECTION 1 GENERAL INFORMATION
1.1 INTRODUCTION ...
1.2 SPLCIFICATIONS...
1.3 OPTIONS...
1.4 Accessories ECTION 2 OPERATION
3.1 INTRODUCTION...
2.2 MECHANICAL INSTALLATION. . .
2.3 ELECTRICAL INSTALLATfON .
2.4 DESCRIPTION OF FRONTPANEL
2.5 DESCRIPTION OF REAR PANEL .
2.β INSTALLATION CHECKS...
2.7 OPERATING PROCEDURE .. .
SECTION 3 THEORY OF OPERATION
3.1 INTRODUCTION...
3.2 OVERALL BLOCK DIAGRAM ...
3.3 C315 - METER BOARD . . ...
3.4 C31G-2 MODULATION BOARD. . .
3.5 DPS2A Power Supply 3.6 DELETED...
3.7 M9W SWEEP Oscillator 3.3 MIOW-G/WIIOW-S - OUTPUT Amplifier 3.9 M172 - SWEEP DRIVE/DAC .
3.10 M29-2 - FM REFERENCE...
3.11 M30-1 - CRYSTAL SOURCE. . . .
3.12 M31A-kHi STEPS...
3.13 M32A- MHz STEPS...
3.14 M33 ? - NARROW Oscillator LOCK.
3.15 M34-WIDE Oscillator LOCK...
3.16 M115 - DOWN Converter ECTION 4 PERFORMANCE TESTS
4.1
INTRODUCTION...
4.2 FREQUENCY RANGE AND RESOLUTION TEST.
4.3 FREOUENCY ACCURACY TEST . ...
4.4 FREOUENCY STABILITY TEST ...
4.5 OUTPUT LEVEL ACCURACY TF5TS...
4.6 HARMON ICS
TEST...
4.7 NON-HARMONJC TEST ...
4.H RESIDUAL AM TEST
...
4.9 RESIDUAL FM
TEST...
4.in INTERNAL MODULATION FREQUENCY I'EST
4 11 PERCENT AM ACCURACY TEST...
4.12 AM BANDWIDTI-I
Tf=5T...
4.13 AM DISTORTION
TEST...
4.14 FM DEVIATION ACCURACY TEST...
4.15 FM BANDWIDTH
TEST...
4.16 FM DISTORTION TEST...
4.17 IMPEDANCE
TEST...
4.13 FI F|
TEST...
PERFORMANCE TEST RECORD...
Downloads:
2279
Download
wavetek--3001--service-user--ID6402.pdf
Gebruikershandleiding
Handleidingen type:
Gebruikershandleiding
Pagina's:
67
Grootte:
2,5 MB
Taal:
engels
Revisie:
Handmatig-ID:
Datum:
november 1981
Kwaliteit:
Gescand document, alles leesbaar.
Upload datum:
15 augustus 2018
MD5 MD5:
fe4026eb-d001-15ed-d5aa-593b3e0dfcb4
Downloads:
1191
Download
wavetek--3001--user--ID11128.pdf