opweb.de

Het gratis downloadarchief voor handleidingen en servicehandleidingen


Waar ben je naar op zoek?


Fluke - 8050A - Digitale multimeter
Fabrikant:
Uitrusting:
8050A
Datum:
1979
Categorie:
Groep:
Subgroep:

Informatie

1-2. Your John Fluke Model 8050A is a portable bench- type Digital multimeter (DMM) with a 4-1 /2 digit liquid crystal display (LCD). The 8050A has all the following industry-standard features: » Voltage measurements from 10 μ to 1000V dcand 10 mV to 750V true-rms ac. • Current measurements from 10 nA to 2A dc and 10 μΑ to 2A true-rms ac. ® Resistance measurements from 10 mH to 20ΜΏ. The 8050A also has several special measurement features. These special features include the following: • Conductance measurements up to 100,000 Mil. • Voltage measurements in decibels, that can be referenced to 1 of 16 user selected reference impedances. ® Resistance ranges that supply enough voltage to turn on a PN junction to allow diodes and transistors to be tested. • The ability to store any input signal as an offset or relative reference value. • Automatic polarity indication and overrange indication. • Protection from overloads and protection from transients of up to 6 kV, 10 microseconds. • Dual-slope integration a/d conversion to ensure noise-free measurements. • Long term calibration stability (1 year). 1-3. The 8050A is warranted for a period of one year upon shipment of the instrument to the original purchaser. Conditions of the warranty are given at the front of this manual. The 8050A is typically powered from ac line voltages but may be powered by the optional rechargeable battery.

toon meer

3 Handleidingen

Gebruikershandleiding met schema's
Handleidingen type:
Gebruikershandleiding met schema's
Pagina's:
97
Grootte:
2,9 MB
Taal:
engels
Revisie:
2 7/84
Handmatig-ID:
530907
Datum:
Kwaliteit:
Gescand document, alles leesbaar.
Upload datum:
19 februari 2009
MD5 MD5:
8c0a3ade-3a51-72d5-2d90-ef6687562db8
Downloads:
3692
Downloads van vorige maand:
3
Download fluke--8050a--user-schematics--ID1437.pdf
Service- en gebruikershandleiding
Handleidingen type:
Service- en gebruikershandleiding
Pagina's:
104
Grootte:
8,5 MB
Taal:
engels
Revisie:
2
Handmatig-ID:
530907
Datum:
Kwaliteit:
Gescand document, alles leesbaar.
Upload datum:
27 januari 2016
MD5 MD5:
9046d898-8f51-2b66-5539-42430b1b1d33

Informatie

1 INTRODUCTION AND SPECIFICATIONS 1-1 1-1. INTRODUCTION 1-1 1-4. OPTIONS AND Accessories 1-1 1-5. SPECIFICATIONS ... 1-1 2 OPERATION ... 2-1 2-1. INTRODUCTION ... 2-1 2-3. SETTING UP YOUR INSTRUMENT ... 2-1 2-4. Unpacking ... 2-1 2-8. AC Line Voltage Requirements 2-1 2-10. Fuse Replacement 2-1 2-13. FRONT PANEL FEATURES 2-2 2-15. Display 2-2 2-18. SIGNAL INPUT LIMITS 2-2 2-20. OPERATING TECHNIQUES 2-3 2-22. AC/DC Voltage (V) 2-3 2-24. AC/ DC Current (mA) 2-3 2-26. Resistance (Ω) 2-7 2-28. Conductance (S = 1Ω) 2-7 2-30. Diode Test 2-7 2-32. Relative (RELATIVE) 2-7 2-36. Decibel (dB) 2-11 2-38. INITIAL CHECKOUT PROCEDURE ... 2-12 2-41. APPLICATIONS 2-12 2-43. DC Voltage Measurement 2-12 2-51. Current Measurement 2-13 2-56. Resistance Measurement 2-13 2-62. Conductance Measurement 2-14 2-80. Relative Measurement 2-16 2-84. AC Voltage and Current Measurement... 2-16 3 THEORY OF OPERATION... 3-1 3-1. INTRODUCTION ... 3-1 3-3. FUNCTIONAL DESCRIPTION 3-1 TITLE PAGE 3-7. A/D Converter 3-1 3-18. Microcomputer ...3-2 3-20. Signal Conditioning ...3-6 3-31. True-RMS Converter 3-8 3-38. Touch-Hold Circuit ...3-8 3-40. Voltage Protection ...3-8 3-43. Current Protection ...3-8 4 MAINTENANCE ... 4-1 4-1. INTRODUCTION ... 4-1 4-4. SERVICE INFORMATION ... 4-1 4-7. GENERAL INFORMATION ... 4-1 4-9. Interior Access... 4-1 4-24. dB Reference Impedance Power-Up Setting... 4-4 4-26. Cleaning ... 4-5 4-28. PERFORMANCE TESTS ... 4-5 4-30. Initial Procedures ... 4-5 4-32. Display Test... 4-5 4-34. Linear Voltage Test ... 4-6 4-36. dB Voltage Test... 4-6 4-38. Current Test... 4-7 4-40. Resistance and Conductance Tests... 4-7 4-42. CALIBRATION ADJUSTMENTS ... 4-8 4-44. DC Calibration ... 4-8 4-46. AC Calibration ... 4-8 4-48. Jumper Selection... 4-8 4-57. TROUBLESHOOTING ... 4-12 5 LIST OF REPLACEABLE PARTS ... 5-1 TABLE OF CONTENTS ... 5-1 5-1. INTRODUCTION ... 5-2 5-3. PARTS ORDERING INFORMATION ... 5-2 6 OPTIONS AND Accessories 6-1 TABLE OF CONTENTS ... 6-1 INTRODUCTION ... 6-2 Accessories 600-1 OPTIONS ... 601-1 7 SCHEMATIC DIAGRAMS ... 7-1 TABLE OF CONTENTS ... 7-1 APPENDIX A ... A-1

toon meer

Downloads:
1130
Downloads van vorige maand:
10
Download fluke--8050a--service-user--ID7619.pdf
Service- en gebruikershandleiding
Handleidingen type:
Service- en gebruikershandleiding
Pagina's:
106
Grootte:
5,1 MB
Taal:
engels
Revisie:
2
Handmatig-ID:
530907
Datum:
Kwaliteit:
Gescand document, alles leesbaar.
Upload datum:
13 februari 2016
MD5 MD5:
645b1f5f-0f6c-33dd-dc5f-e37e20c5466f

Informatie

1 2 TITLE PAGE INTRODUCTION AND SPECIFICATIONS ... 1-1 l-l. INTRODUCTION . I-4. OPTIONS AND ACCESi I-5. SPECIFICATIONS ... 1-1 SORIES... 1-1 ... 1-1 OPERATION ... 2-1 2-1. INTRODUCTION ... 2-1 2-3. SETTING UP YOUR INSTRUMENT ... 2-1 2-4. Unpacking ... 2-1 2-8. AC Line Voltage Requirements ... 2-1 2-10. Fuse Replacement... 2-1 2-13. FRONT PANEL FEATURES... 2-2 2-15. Display ... 2-2 2-18. SIGNAL INPUT LIMITS ... 2-2 2-20. OPERATING TECHNIQUES... 2-3 2-22. AC/DC Voltage (V) ... 2-3 2-24. AC/DC Current (mA) ... 2-3 2-26. Resistance (Ω) ... 2-7 2-28. Conductance (S = IΩ)... 2-7 2-30. Diode Test ... 2-7 2-32. Relative (RELATIVE) ... 2-7 2-36. Decibel (dB)... 2-11 2-38. INITIAL CHECKOUT PROCEDURE ... 2-12 2-41. APPLICATIONS ... 2-12 2-43. DC Voltage Measurement ...,... 2-12 2-51. Current Measurement ... 2-13 2-56. Resistance Measurement ... 2-13 2-62. Conductance Measurement ... 2-14 2-80. Relative Measurement ... 2-16 2-84. AC Voltage and Current Measurement... 2-16 THEORY OF OPERATION... 3-1 3-1. INTRODUCTION ... 3-1 3-3. FUNCTIONAL DESCRIPTION ... 3-1 3-5. CIRCUIT DESCRIPTION... 3-1 TITLE PAGE 3-7. A/D Converter 3-1 3-18. Microcomputer ...3-2 3-20. Signal Conditioning ...3-6 3-31. True-RMS Converter 3-8 3-38. Touch-Hold Circuit ...3-8 3-40, Voltage Protection ...3-8 3-43. Current Protection ...3-8 4 MAINTENANCE ... 4-1 4-1. INTRODUCTION ... 4-1 4-4. SERVICE INFORMATION ... 4-1 4-7. GENERAL INFORMATION ... 4-1 4-9. Interior Access... 4-1 4-24. dB Reference Impedance Power-Up Setting... 4-4 4-26. Cleaning ... 4-5 4-28. PERFORMANCE TESTS ... 4-5 4-30. Initial Procedures ... 4-5 4-32. Display Test... 4-5 4-34. Linear Voltage Test ...*... 4-6 4-36. dB Voltage Test... 4-6 4-38. Current Test... 4-7 4-40. Resistance and Conductance Tests ... 4-7 4-42. CALIBRATION ADJUSTMENTS ... 4-8 4-44. DC Calibration ... ... 4-8 4-46. AC Calibration ... ... 4-8 4-48. Jumper Selection... 4-8 4-57. TROUBLESHOOTING ... 4-12 5 LIST OF REPLACEABLE PARTS ... 5-1 TABLE OF CONTENTS ... 5-1 5-1. INTRODUCTION ... 5-2 5-3. PARTS ORDERING INFORMATION ... 5-2 6 OPTIONS AND Accessories 6-1 TABLE OF CONTENTS ... 6-1 INTRODUCTION ... 6-2 Accessories 600-1 OPTIONS ... 601-1 7 SCHEMATIC DIAGRAMS ... 7-1 TABLE OF CONTENTS ... 7-1 APPENDIX A ... A-1

toon meer

Downloads:
2177
Downloads van vorige maand:
13
Download fluke--8050a--service-user--ID7727.pdf