opweb.de

Het gratis downloadarchief voor handleidingen en servicehandleidingen


Waar ben je naar op zoek?


Fluke - 8026B - Digitale multimeter
Fabrikant:
Uitrusting:
8026B
Datum:
1982
Categorie:
Groep:
Subgroep:

Informatie

INTRODUCTION Your John Fluke Model 8026B is a pocket-size digital multimeter that is ideally suited for application in the field, lab, shop or home. Some of the features of your instrument are: • All VOM functions plus conductance and continuity (8 in all) are included as standard. DC Voltage - 100 µV to 1000V AC Voltage - 100 µV to 750V DC Current - 1 µA to 2000 mA AC Current - 1 µA to 2000 mA Resistance - 0.1 Ω - 20 MΩ Diode Test Conductance - 0.1 ns to 200 ns and .001 ms to 2 ms (S = Siemens = 1/Ω). Continuity - Provides an immediate audible indication when continuity is detected. • True rms ac measurement for signals up to 10 kHz. • CONDUCTANCE - Allows fast, accurate, noise-free resistance measurements up to 10,000 MO. • An easy-to-read high contrast 3 1/2 digit liquid crystal display. • Each range has: . Full auto-polarity operation Overrange indication Effective protection from overloads • Dual slope integration measurement technique to ensure noise-free measurements. • Easy calibration - few adjustments. • Lightweight - 369 grams (13 ounces). • Up to 200 hours of continuous operation can be expccted from a single, inexpensive, 9V, alkaline battery (transistor radio/calculator type). • Low battery voltage automatically detected and displayed. • Line operation is possible using a Model A81 Battery Eliminator (see Section 6, Accessories). • Protected test leads - finger guards on the Probe and shrouded contacts on the connectors discourage accidental contact with circuit voltages. • A full line of Accessories that extend the range and scope of your instrument.

toon meer

1 Handmatig

Service- en gebruikershandleiding
Handleidingen type:
Service- en gebruikershandleiding
Pagina's:
101
Grootte:
2,4 MB
Taal:
engels
Revisie:
Handmatig-ID:
646414
Datum:
juni 1982
Kwaliteit:
Gescand document, alles leesbaar.
Upload datum:
20 januari 2018
MD5 MD5:
631576dc-0565-7d00-38ea-6753d4e6f1e7

Informatie

l-l. INTRODUCTION ...l-l I-3. PREPARING FOR OPERATION ...I-2 1-4. Unpacking ...I-2 I-7. Battery and'or Fuse Installation/Replacement ...I-2 I-9. PHYSICAL FEATURES ...I-4 1-ll. INITIAL CHECK-OUT PROCEDURE ...I-4 I -13 Accessories I-8 I -15. SPECIFICATIONS ...I-8 2 OPERATING INSTRUCTIONS...2-1 2-1. INTRODUCTION ...2-1 2-3. INPUT POWER ...2-1 2-4. Battery Life ...2-1 2-6. Line Power Operation ...2-1 2-8. OPERATING NOTES ...2-1 2-I0. Input Overload Protection ...2-2 2-12. Input Connections to COMMON ...2-3 2-I4. Fuse Check ...2-3 2-16. Fuse Replacement ...2-3 2-18. The Display ...2-3 2-22. OPERATION ...2-4 2-24. MEASUREMENT TECHNIQUES ...2-4 2-26. AC Measurement ...2-4 2-32. Voltage AC DC ...2-10 2-35. Current AC DC ...2-I0 2-39. Resistance...2-13 2-43. Continuity ...2-15 2-46. Conductance ...2-16 2-50. APPLICATIONS ...2-16 2-52. Transistor Tester ...2-16 2-57. Leakage Tester ...2-19 3-1. INTRODUCTION ...3-I . 3-3. OVERALL FUNCTIONAL DESCRIPTION ...3-I 3-8. BLOCK. DIAGRAM ANALYSIS ...3-1 3-9. A/D Converter 3-1 3-I8. Input Signal Conditioners ...3-6 4 MAINTENANCE ...4-1 4-1. INTRODUCTION ...4-I 4-3. SERVICE INFORMATION ...4-I 4-7. GENERAL INFORMATION ...4-2 4-8. Access Information ...4-2 4-17. Cleaning ...4-5 4-I9. Battery/Backup Fuse Replacement ...4-5 4-21. PERFORMANCE TEST ...4-6 4-23. Initial Procedure ...4-6 4-25. Display lest ...4-6 4-27. Resistance/Conductance l est ...4-7 4-29. Continuity Test ...4-7 4-31. DC V phage Test ...4-8 4-33. AC Voltage Test ...4-8 4-35. DC Current l est ...4-9 4-37. CALIBRATION ...4-IÜ 4-40. TROUBLESHOOTING ...4-11 5 LIST OF REPLACEABLE PARTS ... ...5-1 5-I. INTRODUCTION ...5-I 5-4. HOW TO OBTAIN PARTS ...5-I 6 ACCESSORY INFORMATION ...6-1 6-1. INTRODUCTION ...6-1 6-3. DELUXE CARRYING CASE (C-90) ...6-I 6-5. TEMPERATURE Probe (80T-150C and 80T-I50F) . 6-1 6-6. Introduction ...6-1 6-8. Specifications...6-I 6-9. CURRENT TRANSFORMER (80I-600) ...6-4 6-10. Introduction ...6-4 6-12. Specifications ...6-4 6-13. HIGH VOLTAGE Probe 80K-6 6^t 6-14. Introduction ...6-4 6-16. Specifications...6-4 6-17. HIGH VOLTAGE Probe 80K-40 6-4 6-18. Introduction ...6-4 6-20. Specifications...6-4 6-21. HIGH FREQUENCY Probe (83RF)...6-5 6-22. Introduction ...6-5 6-24. Specifications ...6-5 6-25. HIGH FREQUENCY Probe (85RF)...6-5 6-26. Introduction ...6-5 6-28. Specifications ...6-5 6-29. BATTERY ELIMINATOR (A8I-115) ...6-6 6-31. CURRENT SHUNT (80J-1Ü)...6-6 6-32. Introduction ...6-6 6-34. Specifications ...6-7 6-35. AC/DC CURRENT Probe (Y8I00) ...6-7 6-36. Introduction ...6-7 6-39. Specifications ...6-7 6-40. AC CURRENT TRANSFORMER (Y8I0I) ...6-8 6-41 Introduction ...6-8 6-43. Specifications ...6-8 6-44. SAFETY DESIGNED TEST LEAD SE I (Y8132) ... 6-8 6-46. DELUXE TEST LEAD SET (Y8I34) ...6-8 6-48. SLIM F LEX TEST LEAD SET (Y8140)...6-8 7 SCHEMATIC DIAGRAMS ...7-1 APPENDIX A ...A-l

toon meer

Downloads:
1135
Download fluke--8026b--service-user--ID10155.pdf