Informatie
The Fluke 192 196 199 ScopeMeter test tools have three input
channels that are electrically floating with respect to each
other, and with respect to the power adapter input.
Channel A and channel B are Oscilloscope channels with a
60/100/200 MHz bandwidth. The Meter/External Trigger channel
is a combined DMM and external trigger channel with a
limited (20 kHz) bandwidth.
3 Handleidingen
Gebruikershandleiding
Handleidingen type:
Gebruikershandleiding
Pagina's:
116
Grootte:
2,3 MB
Taal:
engels
Revisie:
Rev.2, 2/01
Handmatig-ID:
4822 872 00983
Datum:
Kwaliteit:
Elektronisch document, geen scan, zeer goed leesbaar.
Upload datum:
3 november 2008
MD5 MD5:
7a0c3f46-114d-0892-6ed8-8125214e4e2b
Downloads:
3907
Downloads van vorige maand:
15
Download
fluke--192--user--ID871.pdf
Gebruiksaanwijzing supplement
Handleidingen type:
Gebruiksaanwijzing supplement
Pagina's:
2
Grootte:
124,1 KB
Taal:
engels
Revisie:
Handmatig-ID:
Datum:
Kwaliteit:
Elektronisch document, geen scan, zeer goed leesbaar.
Upload datum:
27 januari 2016
MD5 MD5:
11d3d69a-3ab1-58e3-e927-bfeefbe708f2
Downloads:
1856
Downloads van vorige maand:
14
Download
fluke--192--user-supplement--ID7606.pdf
Servicehandleiding
Handleidingen type:
Servicehandleiding
Pagina's:
206
Grootte:
7,8 MB
Taal:
engels
Revisie:
2
Handmatig-ID:
4822 672 05376
Datum:
maart 2000
Kwaliteit:
Gescand document, alles leesbaar.
Upload datum:
8 januari 2018
MD5 MD5:
69a9d171-f14e-bbb5-90ad-02c12cb59f8e
Informatie
1.1
Introduction...1-3
1.2 Safety
Precautions...1-3
1.3 Caution and Warning
Statements...1-3
1.4
Symbols...1-3
1.5 Impaired
Safety...1
-4 '
1.6 General Safety
Information...1-4
2
Characteristics...2-1
2.1
Introduction...2-3
2.2 Dual Input Oscilloscope 2-3
2.2.1 Isolated Inputs A and B
(Vertical)...2-3
2.2.2
Horizontal...2-4
2.2.3 Trigger and
Delay...2-4
2.2.4 Automatic Connect&View
Trigger...2-4
2.2.5 Edge
Trigger...2-5
2.2.6 Isolated External
Trigger...2-5
2.2.7 Video
Trigger...2-5
2.2.8 Pulse Width
Trigger...2-5
2.2.9 Continuous Auto
Set...2-5
2.2.10 Automatic Capturing Scope
Screens...2-6
2.3 Automatic Scope
Measurements...2-6
2.3.1
General...2-6
2.3.2 DC Voltage
(VDC)...2-6
2.3.3 AC Voltage
(VAC)...2-6
2.3.4 AC+DC Voltage (True
RMS)...2-7
2.3.5 Amperes
(AMP)...2-7
2.3.6
Peak...2-7
2.3.7 Frequency
(Hz)...2-8
2.3.8 Duty Cycle
(DUTY)...2-8
2.3.9 Pulse Width
(PULSE)...2-8
2.3.10
Power...2-8
2.3.11
Phase...2-8
2.3.12 Temperature
(TEMP)...2-9
2.3.13 Decibel
(dB)...2-9
2.4
Meter...2-9
2.4.1 Meter
Input...2-9
2.4.2 Meter
Functions...2-9
2.5 DMM Measurements on Meter
Inputs...2-9
2.5.1
General...2-9
2.5.2 Ohms
(£2)...2-10
2.5.3 Continuity
(CONT)...2-10
2.5.4
Diode...2-10
2.5.5 Temperature
(TEMP)...2-10
2.5.6 DC Voltage
(VDC)...2-10
2.5.7 AC Voltage
(VAC)...2-11
2.5.8 AC+DC Voltage (True
RMS)...2-11
2.5.9 Amperes
(AMP)...2-11
2.6
Recorder...2-11
2.6.1 TrendPlot (Meter or
Scope)...2-11
2.6.2 Scope
Record...2-12
2.7 Zoom, Replay and
Cursors...2-12
2.7.1
Zoom...2-12
2.7.2
Replay...2-12
2.7.3 Cursor
Measurements...2-12
2.8
Miscellaneous...2-13
2.8.1
Display...2-13
7. .8.7 /l
Power...2-13
2.8.3 Probe Calibration...2-13
2.8.4
Memory...2-13
2.8.5
Mechanical...2-13
2.8.6 Optical Interface Port...2-14
2.9
Environmental...2-14
2.10 Zh
Safety...2-14
2.11 10:1 Probe 2-16
2.11.1
Safety...2-16
2.11.2 Electrical
specifications...2-16
2.11.3
Environmental...2-16
2.12 Electromagnetic
Immunity...2-17
3 Circuit
Description...3-1
3.1
Introduction...3-3
3.2 Block
Diagram...3-3
3.3 Start-up Sequence, Operating
Modes...3-7
3.4 Detailed Circuit
Descriptions...3-9
3.4.1 Scope Channel A - Scope Channel
B...3-9
3.4.2 Meter/Ext Trigger
Channel...3-12
3.4.3 Sampling&Triggering
(S-ASIC)...3-14
3.4.4 S-ASIC
supply...3-19
3.4.5
ADC’s...3-19
3.4.6 Digital
Control...3-19
3.4.7
Power...3-24
3.4.8 Slow ADC Corporation RS232 Serial Interface Backlight,
Buzzer...3-28
4 Performance
Verification...4-1
4.1
Introduction...4-3
4.2 Equipment Required For
Verification...4-3
4.3 General
Instructions...4-3
4.4 Operating
Instructions...4-4
4.4.1 Resetting the test
tool...4-4
4.4.2 Navigating through
menu’s...4-4
4.4.3 Creating Test Tool Setup
1...4-5
4.5 Display and Backlight
Test...4-5
4.6 Scope Input A&B
Tests...4-7
4.6.1 Input A&B Vertical Accuracy
Test...4-7
4.6.2 Input A&B DC Voltage Accuracy
Test...4-9
4.6.3 Input A&B AC Voltage Accuracy Test
(LF)...4-11
4.6.4 Input A&B AC Coupled Lower Frequency
Test...4-12
4.6.5 Input A and B Peak Measurements
Test...4-13
4.6.6 Input A&B Frequency Measurement Accuracy
Test...4-14
4.6.7 Input A&B Phase Measurements
Test...4-15
4.6.8 Time Base
Test...4-16
4.6.9 Input A Trigger Sensitivity
Test...4-18
4.6.10 Input A AC Voltage Accuracy (HF) & Bandwidth
Test...4-19
4.6.11 Input B Trigger Sensitivity
Test...4-20
4.6.12 Input B AC Voltage Accuracy (HF) & Bandwidth
Test...4-21
4.6.13 Video
test...4-22
4.7 External Trigger Level
Test...4-26
4.8 Meter (DMM)
Tests...4-27
4.8.1 Meter DC Voltage Accuracy
Test...4-27
4.8.2 Meter AC Voltage Accuracy & Frequency Response
Test...4-28
4.8.3 Continuity Function
Test...4-29
4.8.4 Diode Test Function
Test...4-29
4.8.5 Ohms Measurements
Test...4-29
4.9 Probe Calibration Generator Test...4-31
5 Calibration
Adjustment...5-1
5.1
General...5-3
5.1.1
Introduction...5-3
5.1.2 Calibration number and
date...5-3
5.1.3 General
Instructions...5-3
5.1.4 Equipment Required For
Calibration...5-4
5.2 Calibration Procedure
Steps...5-4
5.3 Starting the
Calibration...5-4
5.4 Contrast Calibration
Adjustment...5-6
5.5 Warming Up &
Pre-Calibration...5-7
5.6 Final
Calibration...5-8
5.6.1 Input A LF-HF
Gain...5-8
5.6.2 Input B LF-HF
Gain...5-9
5.6.3 Input A&B LF-HF
Gain...5-11
5.6.4 Input A&B
Position...5-12
5.6.5 Input A&B Volt
Gain...5-12
5.6.6 DMM Volt
Gain...5-14
5.6.7 Input A& B, and DMM
Zero...5-15
5.6.8 DMM Ohm
Gain...5-15
5.6.9 Calculate
Gain...5-16
5.7 Save Calibration Data and
Exit...5-17
5.8 Probe Calibration...5-18
6 Disassembling the Test
Tool...6-1
6.1.
Introduction...6-3
6.2. Disassembly & Reassembly
Procedures...6-3
6.2.1 Required
Tools...6-3
6.2.2 Removing the Tilt Stand & Hang
Strap...6-3
6.2.3 Replacing the Side-Strap, Changing the Side-Strap
Position...6-3
6.2.4 Opening the Test Tool, Removing the
Battery...6-3
6.2.5 Removing the Main PCA
Unit...6-5
6.2.6 Removing the Display
Assembly...6-6
6.2.7 Removing the Keypad and Keypad
Foil...6-6
6.2.8 Disassembling the Main PCA
Unit...6-7
6.2.9 Reassembling the Main PCA
Unit...6-8
6.2.10 Reassembling the Test
Tool...6-8
7 Corrective
Maintenance...7-1
7.1
Introduction...7-3
7.2 Starting Fault
Finding...7-4
7.3 Charger
Circuit...7-5
7.4 Starting with a Dead Test
Tool...7-6
7.4.1 Test Tool Completely
Dead...7-7
7.4.2 Test Tool Software Does not
Run...7-7
7.4.3 Software Runs, Test Tool not
Operative...7-8
7.5 Miscellaneous
Functions...7-8
7.5.1 Display and Back
Light...7-8
7.5.2 Fly Back Converter 7-9
7.5.3 Slow ADC Corporation +3V3SADC...7-10
7.5.4
Keyboard...7-11
7.5.5 Optical Port (Serial RS232
Interface)...7-12
7.5.6 Channel A, Channel B
Measurements...7-12
7.5.7 Meter Channel (Ext Trigger Probe Cal)...7-13
7.5.8 Input Signal
Acquisition...7-16
7.5.9
ADC’s...7-18
7.5.10 Digital Control &
Memory...7-19
7.5.11 Buzzer
Circuit...7-20
7.5.12 RAM
Test...7-20
7.5.13 Power
ON/OFF...7-21
7.6 Loading Software 7-21
8 List of Replaceable
Parts...8-1
8.1
Introduction...8-3
8.2 How to Obtain
Parts...8-3
8.3 Service
Centers...8-3
8.4 Final Assembly
Parts...8-4
8.5 Main PCA Unit
Parts...8-6
8.6 Main PCA
Parts...8-8
8.7 Accessories 8-26
9 Circuit
Diagrams...9-1
9.1
Introduction...9-3
9.2 Tracing signals in circuit
diagrams...9-3
9.3 Locating Parts & Test
Points...9-3
9.4
Diagrams...9-10
10
Modifications...10-1
10.1 Software modifications...10-3
Downloads:
2021
Downloads van vorige maand:
14
Download
fluke--192--service--ID10095.pdf