General Radio Company 716-C Ander
Fabrikant:
Model:
716-C
Datum:
1959
Categorie:
Groep:
Omschrijving:
Capacitance Bridge

Informatie

The Type 716-C Capacitance Bridge is a Schering bridge which is direct reading in capacitance over the frequency range from 30 c to 300 kc and in dissipation factor at four specific frequencies, 100 c, 1 kc, 10 kc, 100 kc. The resistance balance is made by means of a variable capacitor connected across one of the ratio arms, as shown in Figure 1. Hence its reading in dissipation factor is proportional to the ratio of the applied frequency to the frequency for which the RANGE SELECTOR switch is set. The bridge may also be used for all types of substitution measurements by the addition of a fixed or variable balancing capacitor. The direct-reading scales greatly simplify the necessary calculations for capacitance and dissipation factor.

toon meer

Service-en gebruikershandleiding
Handleidingen type:
Service-en gebruikershandleiding
Pagina’s:
22
Grootte:
9.95 Mbytes (10434607 Bytes)
Taal:
english
Herziening:
Handleidingen-ID:
681-K
Datum:
01 november 1959
Kwaliteit:
Gescand document alle leesbaar.
Upload datum:
30 december 2016
MD5:
11780845be95e98e2d3fd7641424bc0d
Downloads:
330

Informatie

Section 1.0 INTRODUCTION ... 1 1.1 General ... 1 1.2 Range and Accuracy ... 1 Section 2.0 INSTALLATION ... 2 2.1 Accessories Supplied ... 2 ■ ' T 2.2 Accessories Required ... 2 2.3 Connections ... 2 ^ " • Section 3.0 MEASUREMENTS ... 2 3.1 Direct Reading Method ... 2 3.2 Substitution Msthod ... 6 Section 4.0 SPECIAL MEASUREMENTS ... 7 4.1 Measurement of High Resistance ... 7 4.2 Measurement of Large Inductance ... 8 4.3 Partial Substitution Methods ... 8 4.4 Series Substitution Methods ... 9 4.5 Series Resistance Method ... 10 4.6 Parallel Resistance Method ... 10 Section 5.0 OTHER USES ... 11 5.1 Voltage Limits ... 11 5.2 Frequency Range ... 11 5.3 Measurement of Dielectrics ... 12 5.4 Measurement of Direct Capacitance ... 13 5.5 Guard Electrodes ... 14 5.6 Polarizing Voltage ... 15 Section 6.0 CONSTRUCTION ... 15 6.1 Electrical Circuit ... 15 6.2 Adjustments ... 15 -

toon meer

Service-en gebruikershandleiding
Handleidingen type:
Service-en gebruikershandleiding
Pagina’s:
28
Grootte:
17.50 Mbytes (18347201 Bytes)
Taal:
english
Herziening:
Handleidingen-ID:
681-K
Datum:
01 november 1959
Kwaliteit:
Gescand document alle leesbaar.
Upload datum:
30 december 2016
MD5:
b339dc3fc3d79818ce9ee3e830f88a06
Downloads:
449

Informatie

Section 1.0 INTRODUCTION ... 1 1.1 General ... 1 1.2 Range and Accuracy ... 1 Section 2.0 INSTALLATION ... 2 2.1 Accessories Supplied ... 2 2.2 Accessories Required ... 2 2.3 Connections ... 2 Section 3.0 MEASUREMENTS ... 2 3.1 Direct Reading Method ... 2 3.2 Substitution Method ... 6 Section 4.0 SPECIAL MEASUREMENTS ... 7 4.1 Measurement of High Resistance ... 7 4.2 Measurement of Large Inductance ... 8 4.3 Partial Substitution Methods ... 8 4.4 Series Substitution Methods ... 9 4.5 Series Resistance Method ... 10 4.6 Parallel Resistance Method ... 10 Section 5.0 OTHER USES ... 11 5.1 Voltage Limits ... 11 5.2 Frequency Range ... 11 5.3 Measurement of Dielectrics ... 12 5.4 Measurement of Direct Capacitance ... 13 5.5 Guard Electrodes ... 14 5.6 Polarizing Voltage . ... 15 Section 6.0 CONSTRUCTION ... 15 6.1 Electrical Circuit ... 15 6.2 Adjustments ... 15

toon meer

Comments

No comments yet. Be the first!

Add Comment

* Required information
1000