Fluke Biomedical QED 6 Defibrillator
Fabrikant:
Model:
QED 6
Datum:
2007
Categorie:
Groep:
Omschrijving:
Defibrillator Analyzer

Informatie

The Fluke Biomedical QED 6 Defibrillator Analyzer, hereafter referred to as the Analyzer, is a highly versatile and portable instrument. Regular testing of defibrillators and pacemakers is critical to ensure safe and effective operation. The Analyzer accurately verifies the output characteristics of all defibrillators and tests the parameters of non-invasive pacemakers. The Analyzer is battery operated and completely portable. Simple-to-use menu softkeys allow quick access to tests. The Analyzer measures: • The delivered energy in joules (watt-seconds) from a Defibrillator by simulating the Human body’s resistance • The flow of current through that simulated resistance. The standard resistance used by the Analyzer is 50 Ω. Defibrillator energy is measured in one of two ranges: 0-100 joules, or 0-1000 joules. Note The Defibrillator pulse waveform can be replayed via the ECG jacks or paddle plates for viewing on a recorder, or on an oscilloscope for greater detail. • Synchronization time in milliseconds. This parameter is measured by timing the firing delay from either the Q-wave (base) or R-wave (peak) simulated by the Analyzer. The simulated waveform is present at both the ECG jacks and the paddle plates. • The peak voltage and peak current (amps) of the Defibrillator pulse. Overshoot voltage and current measurements of the Defibrillator pulse are calculated and displayed. • The defibrillator’s charge time (the time it takes for a Defibrillator to reach its maximum charge setting). Waveforms, including ECG, arrhythmias, and performance, help verify monitor and recorder accuracy, and also test the automatic defibrillator’s ability to recognize the maximum charge and fire. All waveforms are present at the ECG jacks, the paddle plates and scope output. Utilities allow the setting of Serial RS232 communication parameters to download results to a Printer or computer. Display contrast can be adjusted to obtain the best view of the LCD display.

toon meer

Gebruikershandleiding
Handleidingen type:
Gebruikershandleiding
Pagina’s:
72
Grootte:
1.85 Mbytes (1937186 Bytes)
Taal:
english
Herziening:
Handleidingen-ID:
2204510
Datum:
01 september 2007
Kwaliteit:
Elektronisch document, geen scan, zeer goed leesbaar.
Upload datum:
10 februari 2018
MD5:
32b89b77db0aa64cfb21c320c5b3216a
Downloads:
151

Informatie

1 Introduction and Specifications ... Description ... Unpacking and Inspection ... General Safety Considerations ... Symbols ... Warnings and Cautions ... Instrument Familiarization ... Front Panel ... Back Panel ... Upgrading the Analyzer ... Specifications ... Accessories ... Operation ... Introduction ... Powering Up ... Adjusting Display Contrast ... Measuring Defibrillator Energy ... Evaluating Ability to Fire ... Defibrillator Pulse Playback ... Viewing Oscilloscope Output ... Preparation for Viewing ... Viewing a Test ... Measuring Synchronization ... Generating Test Waveforms ... Testing High Level Out ... Measuring Peak Voltage, Current, and Overshoot ... Measuring Charge Time (Models M and H) ... Pacemaker (Non-Invasive) Testing ... Pacemaker Refractory Period Testing ... Programming an Automatic Test Sequence ... Program Selection ... Defib Setting ... Energy Limits ... Charge Time ... Sync Time ... Peak ... Overshoot ... ECG Performance ... Pacer ... Running an Automatic Test Sequence ... Printing the Analyzer Report Header ... Resetting the Analyzer to Factory Defaults ... Remote Operation ... Preparing for Serial Communications ... Ansur Software Control ... 3 Maintenance, Service, and Calibration ... Maintenance ... Avoiding Damage ... Cleaning ... Troubleshooting ... Service and Calibration ...

toon meer

Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
Captcha Image