Fluke 732A Voeding
Fabrikant:
Model:
732A
Datum:
1983
Categorie:
Groep:
Omschrijving:
DC Reference Standard

Informatie

1-2. The Fluke Model 732A is a highly stable, rugged, and transportable, solid state, dc voltage reference standard. The 732A has 10V, 1.018V and IV outputs. These outputs are available on front panel binding posts. The calibration adjustments for the IOV, 1.018V and IV outputs are accessible through the front panel. A nonconducting adjustment tool is supplied with the unit for this purpose. 1 -3. All outputs of the 732A can be shorted indefinitely without damage. Recovery occurs in less than 2 minutes after the short is removed, with no loss of stability. 1-4. The stability and accuracy of the 732A allow direct substitution for saturated standard cells in many applications. The stability specification of 0.5 ppm for 30 days is achieved by enclosing the reference Amplifier and output divider of the 732A in a high thermal gain oven. Full accuracy is attained over the specified ambient temperature range of 23 ± 5°C (64.4 to 82,4<1F). Variations in oven temperature may be monitored externally via the OVEN TEMP THERMISTOR terminals on the front panel. 1-5. The 732A may be powered from ac line power, an internal rechargeable battery, or an external low voltage ac or dc source. The 732A is designed to be powered continuously, including during storage or shipment. The back-up battery will continue to operate the 732A for up to 12 hours. Either line or battery power may be removed without affecting the output. The battery is kept charged by an internal battery charger when operating from ac line power, or from the external low voltage ac or dc source. 1“6. Various front panel LEDs (indicators) provide a continuous indication of the operating status of the 732A, The AC PWR indicator illuminates in the presence of ac line power. The BTRY CHG indicator is on steadily for normal charging activity, and is off when the battery is charged. The IN CAL indicator monitors the’ input voltage to the Reference and Oven. Should this voltage fall below that needed to keep the 732A operational, the IN CAL indicator is latched off, indicating a loss of power and standardization, Once power is restored and standardization toäs been verified, the IN CAL indicator can be reset. 1-7. The 732A may be used on the bench or rack mounted* The 732A is a half-rack width instrument and occupies 4 standard 1.75 inch rack spaces. Accessories for the 732A are listed in Table 1-1 and described in more detail in Section 6 of this manual. There are no options available for the 732A,

toon meer

Service-en gebruikershandleiding
Handleidingen type:
Service-en gebruikershandleiding
Pagina’s:
114
Grootte:
3.84 Mbytes (4026024 Bytes)
Taal:
english
Herziening:
Handleidingen-ID:
645051
Datum:
Kwaliteit:
Gescand document alle leesbaar.
Upload datum:
2016 01 27
MD5:
90463730ff5c4f9c89b7ea2d6ac8269d
Downloads:
825

Informatie

1 INTRODUCTION AND SPECIFICATIONS 1-1 1-1. INTRODUCTION ... M 1-8. SPECIFICATIONS ... 1-1 2 OPERATION ... 2-1 2-1. INTRODUCTION ... 2-1 2-3. SHIPPING INFORMATION ... 2-1 2-7. INSTALLATION 2-1 2-9, FRONT AND REAR PANEL FEATURES ... 2-1 2-11. OPERATING NOTES 2-1 2-12, Introduction ... , * ... 2-1 2-14. Input Power Requirements ... ,,,,, ... 2-1 2-16. AC Line Voltage Selection ... ,,, ... 2-1 2-18. Fuse Replacement ... , ... * ... 2-1 2-20. Backup Operating Power ... .. 2-5 2-22. Battery Charging ,.,,, ... 2-5 2-25, IN CAL Indicator and RESET Terminal ... 2-5 2-27. Portability ... 2-5 2-29. Guarded Operation ,,,, ... *.2-5 2-33. Oven Temperature Thermistor ... 2-6 2-36. Minimizing Error Sources ... 2-6 2-45. OPERATION ... 2-7 3 THEORY OF OPERATION ... 3-1 3-1 INTRODUCTION ... 3-1 3-3. OVERALL FUNCTIONAL DESCRIPTION ... 3-1 3-8. CIRCUIT DESCRIPTION 3-1 3-10. Power supply (A3 and A4) , ♦,, ♦ ... * ... 3-1 3-14, Voltage Monitor ... 3-1 3-17, Reference Circuit, A5 ... 3-2 3-20. Output Divider ... * ... 3-2 3-22, Oven Controller ,, .. 3-2 3-25, Battery Charger ... 3-2 4 MAINTENANCE ... 4-1 4-1. INTRODUCTION ... 4-1 4-5, SERVICE INFORMATION 4-1 4-8. GENERAL MAINTENANCE 4-1 4-9. Access Procedure ... * ... - ... 4-1 4-19, Oven Disassembly ... < ... 4-6 4-21, Front Panel Removal ... 4-6 4-23, Cleaning ... ... 4-6 4-26, Fuse Replacement ... 4-6 4-28. AC Line Voltage Change ... 4-6 4-30. ACCEPTANCE TEST ... 4-8 4-32, CALIBRATION ... 4-8 4-35. Null Verification ... ,, ♦ ... , ... 4-8 4-37, Procedure A: Calibrate to Certified 732A ... 4-9 4-39. Procedure B; Calibration to Standard Cells ... 4-10 4-41. SERVICE/REPAIR PROCEDURES ... 4-14 4-42. Introduction ... 4-14 4-44. Battery Charger Adjustment Procedure ... * ... 4-14 4-46. TROUBLESHOOTING ... 4-14 4-47. Introduction . .**♦ ... 4-14 4-49, External Symptom Troubleshooting ... 4-16 4-51. Internal Voltage Measurements ... 4-16 4-53. Oven Repair ... 4-16 5 LIST OF REPLACEABLE PARTS ... 5-1 TABLE OF CONTENTS ... 5-1 6 ACCESSORIES ... 6-1 INTRODUCTION ... 6-1 6-3, DUAL MOUNTING FASTENERS (M00-800-5237) ... 6-1 6-5. HALF-WIDTH RACK MOUNT KIT (M07-203-601) ... 6-1 6-7. FULL-WIDTH RACK MOUNT KIT ( M07-200-603) ... 6-1 6-9, LOW THERMAL EMF CABLE ASSEMBLY (5440A-7002) ... 6-1 6-11. BATTERY PACK (732A-7001) ... 6-1 6-13. TRANSIT CASE (732Λ-7002) ... 6-1 7 GENERAL INFORMATION ... 7-1 7A MANUAL CHANGE INFORMATION ... 7A-1 8 SCHEMATIC DIAGRAMS ... 8-1 TABLE OF CONTENTS ... 8-1 INDEX ... 8-12

toon meer

Service-en gebruikershandleiding
Handleidingen type:
Service-en gebruikershandleiding
Pagina’s:
94
Grootte:
3.68 Mbytes (3854198 Bytes)
Taal:
english
Herziening:
Handleidingen-ID:
645051
Datum:
1983 05 01
Kwaliteit:
Gescand document alle leesbaar.
Upload datum:
2017 02 04
MD5:
fc3827e946e6a7f7549ec6c53ba7e07f
Downloads:
796

Informatie

1 INTRODUCTION AND SPECIFICATIONS 1-1 1-l. INTRODUCTION ... l-l !-8. SPECIFICATIONS ... l-l 2 OPERATION ... 2-1 2-1. INTRODUCTION ... 2-1 2-3. SHIPPING INFORMATION ... 2-1 2-7. INSTALLATION ... 2-1 2-9. FRONT AND REAR PANEL FEATURES ... 2-1 2-11. OPERATING NOTES ... 2-1 2-12. Introduction ... 2-1 2-14. Input Power Requirements ... 2-1 2-16. AC Line Voltage Selection ... 2-1 2-18. Fuse Replacement ... 2-1 2-20. Backup Operating Power ... 2-5 2-22. Battery Charging ... 2-5 2-25. IN CAL Indicator and RESET Terminal ... 2-5 2-27. Portability ... 2-5 2-29. Guarded Operation ... 2-5 2-33. Oven Temperature Thermistor ... 2-6 2-36, Minimizing Error Sources ... 2-6 2-45. OPERATION ... 2-7 3 THEORY OF OPERATION ... 3-1 3-1 INTRODUCTION ... 3-1 3-3. OVERALL FUNCTIONAL DESCRIPTION ... 3-1 3-8. CIRCUIT DESCRIPTION ... 3-1 3-10. Power supply (A3 and A4) ... 3-1 3-14. Voltage Monitor ... 3-1 3-17. Reference Circuit, A5 ... 3-2 3-20. Output Divider ... 3-2 3-22. Oven Controller ... 3-2 3-25. Battery Charger ... 3-2 4 MAINTENANCE ... 4-1 4-1. INTRODUCTION ... 4-I 4-5. SERVICE INFORMATION ... 4-1 4-8. GENERAL MAINTENANCE ... 4-1 SECTION TITLE PAGE 4-9. Access Procedure ... 4-1 4-19. Oven Disassembly ... 4-6 4-21. Front Panel Removal ... 4-6 4-23. Cleaning ... 4-6 4-26. Fuse Replacement ... 4-6 4-28. AC Line Voltage Change ... 4-6 4-30. ACCEPTANCE TEST ... 4-8 4-32. CALIBRATION ... 4-8 4-35. Null Verification ... 4-8 4-37. Procedure A: Calibrate to Certified 732A ... 4-9 4-39. Procedure B: Calibration to Standard Cells ... 4-10 4-41. SERVICE/REPAIR PROCEDURES ... 4-14 4-42. Introduction ... 4-14 4-44. Battery Charger Adjustment Procedure ... 4-14 4-46. TROUBLESHOOTING ... 4-14 4-47. Introduction ... 4-14 4-49. External Symptom Troubleshooting ... 4-16 4-51. Internal Voltage Measurements ... 4-16 4-53. Oven Repair ... 4-16 5 LIST OF REPLACEABLE PARTS ... 5-1 TABLE OF CONTENTS ... 5-1 6 Accessories ... 6-1 INTRODUCTION ... 6-1 6-3. DUAL MOUNTING FASTENERS (M00-800-5237) ... 6-1 6-5. HALF-WIDTH RACK MOUNT KIT (M07-203-601) ... 6-1 6-7. FULL-WIDTH RACK MOUNT KIT { M07-200-603) ... 6-1 6-9. LOW THERMAL EMF CABLE ASSEMBLY (5440A-7002) ... 6-1 6-11. BATTERY PACK (732A-7001) ... 6-1 6-13. TRANSIT CASE (732A-7002) ... 6-1 7 GENERAL INFORMATION ... 7-1 7A MANUAL CHANGE INFORMATION ... 7A-1 8 SCHEMATIC DIAGRAMS ... 8-1 TABLE OF CONTENTS ... 8-1 INDEX ... 8-12

toon meer