Dräger Medical PA-90 Series Systeem voor verdoving
Fabrikant:
Model:
PA-90 Series
Datum:
1996
Categorie:
Groep:
Omschrijving:
Servicehandboek
Handleidingen type:
Servicehandboek
Pagina’s:
60
Grootte:
5.53 Mbytes (5795534 Bytes)
Taal:
english
Herziening:
1
Handleidingen-ID:
Datum:
01 augustus 1996
Kwaliteit:
Gescand document alle leesbaar.
Upload datum:
22 augustus 2019
MD5:
6b63a3a1a636bead8775ca3c40a9b526
Downloads:
133

Informatie

I Theory of Operation 1 Backplate ... 2 1.1 Purpose ... 2 1.2 Construction ... 2 1.3 Features ... 2 2 Harness ... 2 2.1 Purpose ... 2 2.2 Construction ... 2 2.3 Features ... 2 3 Pressure Reducer ... 3 3.1 Purpose ... 3 3.2 Construction ... 3 3.3 Features ... 3 3.4 Technical Data ... 3 4 Chest Mounted Whistle Warning Unit ... 4 4.1 Purpose ... 4 4.2 Construction ... 4 4.3 Technical Data ... 4 5 Chest Gauge ... 5 5.1 Purpose ... 5 5.2 Construction ... 5 5.3 Features ... 5 6 Lung Demand Regulator ... 7 6.1 Purpose ... 7 6.2 Features ... 7 6.3 Technical Datai ... 7 7 Panorama Nova Mask ... 9 7.1 Purpose ... 9 7.2 Construction ... 9 7.3 Features ... 9 # 7.4 Technical Data ... 9 1 8 Cylinder and Valve Assembly ... 10 8.1 Purpose ... 10 8.2 Features ... 10 8.3 Technical Data ... 10 II Disassembly/Assembly 1 Pneumatic Arrangement Maintenance ... 2 1.1 Replacing Pressure Gauge ... 2 1.2 Disassembly/Assembly of Whistle ... Warning Unit ... 3 1.3 Replacing High Pressure Hose ... 4 1.4 Replacing Medium Pressure Hose ... 5 2 Demand Regulator Maintenance ... 6 2.1 Replacing Diaphragm ... 6 2.2 Replacing Balanced Piston Unit ... 7 2.3 Replacing/Refitting PP Arm Return Spring ... 8 2.4 Replacing Balanced Piston Springs ... 9 2.5 Replacing Demand Regulator Hose . . 11 3 Panorama Nova Mask ... 12 3.1 Changing the Mask Lens ... 12 3.2 Changing the Exhalation Valve ... 13 3.3 Changing the Speech Diaphragm ... 13 3.4 Changing the Connector ... 14 4 Backplate/Pneumatic Lines ... 15 5 Cylinder Valve ... 16 5.1 High Pressure Gauge ... 16 5.2 Burst Disc ... 16 5.3 Handwheel ... 17 5.4 Valve Removal ... 17 Testing/Troubleshooting ... 2 1.1 Test Kit Operations ... 2 1.1.1 Leak Test ... 2 1.1.2 High Pressure Cylinder Test ... 2 1.1.3 High Pressure Leak Test ... 2 1.1.4 Medium Pressure Test ... 2 1.1.5 Whistle Activation ... 3 1.1.6 LDV Positive Pressure Leak 1.1.7 LDV Static Positive Pressure ... Test ... 3 1.1.8 LDV Negative Pressure Leak ... Test ... * ... * 3 1.1.9 LDV Bypass Function ... 3 1.1.10 Mask Leak Test ... 4 1.1.11 Exhalation Valve Opening Test 4 IV Maintenance Schedules/ Equipment 1.1 Maintenance Procedures ... 2 1.1.1 Facepiece ... 2 1.1.2 Lung Demand Valve (LDV) ... 3 1.1.3 Pressure Reducer and Hose Assembly ... 5 1.1.4 After Each Use ... 5 1.1.5 Functional Test ... 5 1.2 Maintenance Schedule ... 7 1.3 Maintenance Equipment ... 8 1.3.1 Maintenance Support Equipment ... 8 1.3.2 Torque Specifications ... 10 1.3.3 Lubricants and Adhesives ... 11 V Service Reporting 1 Service Reporting ... 2 2 SCBA Service Log ... 3 3 Terms of Payment ... 4 4 Return Goods Policy ... 4 5 Emergency and Rush Orders ... 4 6 Return Goods Authorization ... 5 7 National Draeger's Product Service In The U.S.A ... 6 VI Service Instruction History

toon meer

Comments (0)

No comments yet. Be the first!

Add Comment

* Required information
1000
Captcha Image