3.1 GENERAL.
The 30L-1 is a portable r-f linear power Amplifier,
including plate power and bias supplies. It is capable of
1000 watts PEP input power in SSB or 1000 watts d-c input in
CW service with any exciter (such as the KWM-1, KWM-2/2A, or
32S-1) capable of 70 watts PEP output. It covers the amateur
bands between 3.5 and
29.7 me. In addition, the Amplifier may be operated outside
the amateur bands over certain ranges of frequency. These
ranges are specified in table 4-1. The power Amplifier stage
uses four 811A triodes connected in parallel with cathode drive.
3.2 INPUT CIRCUITS.
Refer to figures 3-1 and 7-2. Broadband pi-network circuits
couple the exciting signal into the cathode circuits of the
power Amplifier tubes. The tuned input circuits provide
increased efficiency, reduced distortion, and a better
impedance matchfor the exciter than normally would be
obtained with an untuned input. Tuning adjustments are not
required except for operation outside the amateur bands.
3.3 OUTPUT CIRCUITS.
The plate circuit of the power Amplifier is tuned by a pi
network consisting of C32, L9, L10, and C33. Capacitor C32-
resonates the tank circuit at the frequency in use. It is
adjusted by the TUNING control on the front panel. The
four-gang capacitor, C33, is adjusted by the LOADING control
to match the pi- network circuit to the impedance presented
by the Antenna and feed system in use. Output from the plate
tank circuit is connected through the contacts of Antenna
changeover relay, Kl, to the Antenna when the control
circuits are energized.
3.4 Power Supply CIRCUITS.
Two d-c power supplies and one a-c filament supply are
included in the 30L-1, The Amplifier may be connected to a
115-volt single-phase or to a 230-volt, three-wire,
single-phase source. Where practical, the
2 30-volt, three-wire connection is recommended. Power
transformer T1 has two primary windings. These windings are
connected in parallel for 115-volt operation,. and in series
for 230-volt operation. The
6.3-volt secondary winding provides filament power for the
811A tubes through r-f choke L8. It also powers the pilot
lamp in the meter. Another secondary winding applies voltage
through surge resistor R9 to semiconductor rectifier CR20.
This is a half-wave circuit connected to furnish blocking
bias to the Amplifier tubes under receive conditions and
operating bias when transmitting. It also furnishes power
for changeover relay Kl. Voltage from the third secondary
winding is
applied to two semiconductor rectifier strings connected in
a full-wave voltage doubler configuration. These strings
consist of CR1-CR8, C44-C51 in one string, and CR9-CR16,
C52-C59 in the other. The parallel capacitors equalize the
reverse voltages impressed across the diode junctions and
protect against damage by transients. The output of this
supply provides approximately 1600 volts d-c under load for
the Amplifier tube plates.
Handleidingen type:
Service-en gebruikershandleiding
Pagina’s:
46
Grootte:
3.96 Mbytes (4155210 Bytes)
Taal:
english
Herziening:
Handleidingen-ID:
Datum:
1965 01 01
Kwaliteit:
Gescande document, lezen deels slecht, deels niet leesbaar.
Upload datum:
2017 08 03
MD5:
402aae02ae7758fed4a08525e97bae6b
Downloads:
753
Informatie
This manual describes Amplifier, RF AM-3979/FRC-93 (fig*
2-1) and contains instructions for installation, operation
and principles of operation, service instructions for direct
support, general support, and depot maintenance.
Instructions for cleaning, inspection, and operator and
organizational maintenance of Amplifier, KF AM-3979/FRC-93
are also included. This is a first-edition manual containing
preliminary and unreviewed information compiled by the
manufacturer of the equipment. Judicious caution should be
exercised in using the information in this manual until it
is replaced by a revised edition. Sections VIII and IX have
been added to include the preventive maintenance checks and
services.
Handleidingen type:
Service-en gebruikershandleiding
Pagina’s:
26
Grootte:
1.67 Mbytes (1753489 Bytes)
Taal:
english
Herziening:
Handleidingen-ID:
523-0122-00
Datum:
1961 08 15
Kwaliteit:
Gescande document, lezen deels slecht, deels niet leesbaar.
Upload datum:
2017 08 04
MD5:
9dcb2eeac08f9ad9b94ff7d6f371f2dd
Downloads:
536
Informatie
I
INSTALLATION ... 11
1.1
Unpacking ... 1-1
1.2 Power Transformer
Connections ... 1-1
1.3
Cabling ... 1-1
1.3.1 Traveling
Station ... 1-1
1.3.2 Home
Station ... 1-1
1.3.3 KWM-1 Serial Numbers Above
861 ... 1-1
1.3.4 KWM-1 Serial Numbers Below
861 ... 1-5
1.4 Installation with Other Makes of
Exciters ... 1-5
II
OPERATION ... 2-1
2.1 Operation in Amateur
Bands ... 2-1
2.2 Operation with Other Makes of
Exciters ... 2-1
2.3 Operation Outside Amateur
Bands ... 2-1
III PRINCIPLES OF OPERATION
... 3-1
3.1
General ... 3-1
3.2 Input
Circuits ... 3-1
3.3 Output
Circuits ... 3-1
3.4 Power Supply
Circuits ... 3-1
3.5 Safety Interlock
Circuits ... 3-1
3.6 Power Control
Circuits ... 3-1
3.7 ALC
Circuits ... 3-1
3.8 Metering
Circuits ... 3-2
IV
MAINTENANCE ... 4-1
4.1
General ... 4-1
4.2 Removal of Cabinet and
Covers ... 4-1
4.3 Blower
Lubrication ... 4-1
4.4 Alignment of R-F Input
Circuits ... 4-1
4.5 Meter Lamp
Replacement ... 4-2
4.6 Tube
Replacement ... 4-2
V
SPECIFICATIONS ... 5-1
VI PARTS
LIST ... 6-1
VII
ILLUSTRATIONS ... 7'1
Handleidingen type:
Schema
Pagina’s:
4
Grootte:
132.40 Kbytes (135579 Bytes)
Taal:
english
Herziening:
Handleidingen-ID:
Datum:
Kwaliteit:
Gescande document, lezen deels slecht, deels niet leesbaar.
Upload datum:
2017 08 04
MD5:
f5db14cf75a62eae412829be4643b985
Downloads:
494