California Instruments 501TC Voeding
Fabrikant:
Geen foto beschikbaar!
Misschien kan je een foto uploaden voor de
California Instruments 501TC ?
Als je nog andere handleidingen hebt voor de
California Instruments 501TC kun je hier de bestanden uploaden .
Model:
501TC
Datum:
1986
Categorie:
Groep:
Omschrijving:
Power Source
Informatie
The California Instruments Model 501TC Power Amplifier is a
solid state, high performance, low distortion power source
that provides up to 500 VA output when used with the proper
Plug-In Oscillator. The Model 501TC Power Source is
illustrated in Figure 1-1. Full power output is available in
two different voltage ranges and over the frequency range
from 45 Hz to 5 KHz.
These full power voltage ranges are:
1) 105 to 135 volts rms for normal single phase 115 volt
applications and for three phase 208 to 234 volt
line-to-line applications.
2) 210 to 270 volts rms for normal single phase 230 volt
applications and for three phase 208 to 270 volt
applications where open Delta operation is acceptable.
For two phase and three phase operation, at least two power
amplifiers must be combined together with the applicable
multi-phase Oscillator. Two power amplifiers will provide a
total of 1000 VA two phase power (Model 1000TC/2-2), or 1000
VA of three phase power (Model 1000TC/2-3D) in the open
Delta configuration. Three power amplifiers will provide
1500 VA of three phase power in the wye configuration (Model
1500TC/3-3).
Handleidingen type:
Service-en gebruikershandleiding
Pagina’s:
52
Grootte:
11.00 Mbytes (11533995 Bytes)
Taal:
english
Herziening:
Handleidingen-ID:
Datum:
Kwaliteit:
Gescande document, lezen deels slecht, deels niet leesbaar.
Upload datum:
2015 12 20
MD5:
530ec3bda3b2950e81ed0285c4c550a4
Downloads:
1151
Informatie
GENERAL DESCRIPTION PACE
1. 1 INTRODUCTION 1
1.2 GENERAL DESCRIPTION 1
1.3 ACCESSOR Y EQUIPMENT 1
INSTALLATION AND OPERATION
2. 1 UNPACKING 5
2.2 POWER REQUIREMENTS 5
2.3 CIRCUIT BREAKER REQUIREMENTS 6
2.4 OUTPUT VOLTAGE RANGE AND 6 METER RANGE
2.5 ACCEPTANCE TEST PROCEDURE 6
2.6 MECHANICAL INSTALLATION 8
2.7 INPUT POWER WIRING 8
2.8 OUTPUT POWER WIRING 8
2. 9 FRONT PANEL CONTROLS 8
2. 10 OPERATION OVER EXTENDED FREQUENCY 9 RANGE
THEORY OF OPERATION
3.1 GENERAL H
3.2 DETAILED CIRCUIT DESCRIPTION 11
CALIBRATION PROCEDURE
4.1 GENERAL 17
4.2 TEST EQUIPMENT REQUIRED 18 4. 3 INITIAL ADJUSTMENTS 18
4.4 AC LINE INPUT POWER AND OVERLOAD 19 ADJUSTMENT
4.5 VOLTAGE, POWER OUTPUT AND HARMONIC 22 DISTORTION
4.6 LINE REGULATION 22
4.7 LOAD REGULATION ADJUSTMENT 24
4.8 AMPLITUDE STABILITY 25
4.9 FREQUENCY RESPONSE 25 4. 10 AC NOISE LEVEL 25 4. 11 0. 7
LAGGING POWER FACTOR 26 4. 12 0.7 LEADING POWER FACTOR 27
MAINTENANCE AND TROUBLESHOOTING
5.1 GENERAL 30
5.2 TROUBLESHOOTING 30
CIRCUIT DIAGRAMS
6.1 GENERAL 31
6.2 REFERENCE DESIGNATIONS 31
REPLACEABLE PARTS
7.1 GENERAL . 36
7.2 ORDERING INFORMATION 36
PARTS LIST
APPENDIX A
CODE LIST OF MANUFACTURERS