BK Precision 2520 Oscilloscoop
Fabrikant:
Geen foto beschikbaar!
Misschien kan je een foto uploaden voor de
BK Precision 2520 ?
Als je nog andere handleidingen hebt voor de
BK Precision 2520 kun je hier de bestanden uploaden .
Model:
2520
Datum:
Categorie:
Groep:
Omschrijving:
Informatie
DIGITAL FEATURES
1024 x 8-Bit Memory
Vertical resolution of 1 in 256 {approximately 30 steps/div)
and horizontal resolution of 1 in 1024 (100 samples/div).
2 Msample/sec Sampling Rate
Allows capture of one time events with pulse widths of 5 ps
or greater.
Equivalent Time Sampling
Allows repetitive waveforms of up to 20 MHz to be digitized
and stored.
Capture Pretrigger Information
Allows selection of 0%, 25%, 75%, or 100% of the stored
waveform to be pretrigger information.
Armed Store Mode
In the Armed/Store mode the Oscilloscope begins storing
information on trigger and continues through the entire sweep.
Roll Mode
In the Roll mode of operation, the trace moves across the
display from right to left like a strip chart recorder.
Ideal for capturing very slow events and pretrigger information.
DUAL TRACE FEATURES Dual Trace
Model 2520 has two vertical input channels for displaying
two waveforms simultaneously. Selectable single trace
(either CH 1 or CH 2) or dual trace for both analog and
digital operating modes. Alternate or chop sweep
automatically selected by TIME/DIV control.
Sum and Difference Capability
Permits algebraic addition or subtraction of channel 1 and
channel 2 waveforms in the analog operating mode, displayed
as a single trace. Useful for differential voltage and
distortion measurements.
CRT FEATURES
Rectangular CRT
Rectangular CRT with large 8 x 10 centimeter viewing area.
Internal 8 x 10 division graticule eliminates parallax error.
Convenience
Trace rotation electrically adjustable from front panel. 10%
and 90% markers for rise time measurements.
VERTICAL FEATURES
High Sensitivity
2 mV/div sensitivity for full bandwidth.
Calibrated Voltage Measurements
Accurate voltage measurements (±3%) on
12 calibrated ranges from 2 mV/div to 10 V/ div* Vertical
gain fully adjustable between calibrated ranges.
CWTT1?P A *t»TTD T?C
DW JuiSrX^ 1! Hrill UIvJliu
Calibrated Time Measurements
Accurate (±3%) time measurements. In analog display mode,
Model 2520 has 18 calibrated ranges from 0.2 s/div to 0.5
tfs/div. Sweep time is fully adjustable between calibrated
ranges. In digital display mode, 26 calibrated ranges are
available from
0.5 ps/div to 50 sec/div.
X10 Sweep Magnification
Allows closer examination of waveforms, increases maximum
sweep rate to 50 ns/div. Allows digitized waveforms to be
expanded even after they have been stored.
TRIGGERING FEATURES
Auto Sweep
Selectable Auto sweep provides sweep without trigger input,
automatically reverts to triggered sweep operation when
adequate trigger is applied.
Triggered Sweep (Normal Triggering)
Sweep remains at rest unless adequate trig-* ger signal is
applied. Fully adjustable trigger level and (+) or (-) slope.
Three Trigger Sources
Three trigger source selections, including CH 1, CH 2, and
Ext Trig.
Three Trigger Coupling Choices
Selectable AC, DC, or TV trigger coupling.
Video Sync
Frame or Line triggering selectable for observing composite
video waveforms.
X-Y Operation
Channel 1 can be applied as horizontal deflection (X-axis)
while channel 2 provides vertical deflection (Y-axis).
OTHER FEATURES
Z MOD Input
Intensity modulation capability permits time or frequency
markers to be added. Trace decreases in intensity with
positive signal, TTL compatible.
Built-In Probe Adjust Square Wave
A 1 V p~p, 1 kHz square wave Generator permits Probe
compensation adjustment.
Supplied With Probes
Oscilloscope comes with two identical 10:1 probes (Model PR-47).
Plotter Output
Rear panel outputs allow a stored waveform to be fed to an
analog plotter.
Handleidingen type:
Gebruikershandleiding
Pagina’s:
42
Grootte:
2.67 Mbytes (2795341 Bytes)
Taal:
english
Herziening:
Handleidingen-ID:
Datum:
Kwaliteit:
Gescand document alle leesbaar.
Upload datum:
2017 01 24
MD5:
ad844c47a7497d3bffa4430d233820ec
Downloads:
469
Informatie
TEST INSTRUMENT SAFETY ... inside
front cover
FEATURES ... 1
SPECIFICATIONS ... 3
CONTROLS AND INDICATORS ... 6
Vertical Controls ... 6
Horizontal Controls ... 8
Digital (Store) Mode Controls ... 9
Rear Panel Controls ... 10
OPERATING INSTRUCTIONS ... 12
Safety Precautions ... * 12
Equipment Protection Precautions ... 12
Operating
Tips ... 13
Initial Starting Procedure ... 14
Single Trace Display ... 14
Dual Trace Display ... 14
Triggering ... 15
Magnified Sweep Operation ... 16
X-Y Operation ... 17
Video Signal Observation ... 17
Digital (Store Mode) Operation ... 17
APPLICATION S ... 21
DC Voltage Measurements ... 21
Measurements Of Voltage Between
Two Points On AW avef orm ... 21
Elimination Of An
Undesired Signal Component ... 22
Time Measurements ... 22
Page
Frequency Measurements ... 24
Pulse Width Measurements ... 25
Pulse Rise Time And
Fall Time Measurements* ... 25
Time Difference Measurements ... 26
Phase Difference Measurements ... 27
Relative Measurements ... 28
X~Y Mode Applications ... 30
Viewing One Time Events ... 31
Viewing Very Slow Signals ... 32
Capturing Telephone Dial Pulses ... 32
Evaluating Switching Devices ... 33
Testing Battery Back-Up Systems ... 33
Recording Lightning Induced Surges On Power
Lines ... 34
MAINTENANCE ... 35
Fuse Replacement ... 35
Line Voltage Selection ... 35
Periodic Adjustments ... 35
Calibration Check ... 36
Instrument Repair Service ... 36
APPENDIX I Important Considerations For Rise Time And Fall
Time Measurements ... 37
APPENDIX H Unique Character si tics Of Digital Storage
Oscilloscopes ... 38
WARRANTY SERVICE INSTRUCTIONS ... 40
LIMITED ONE-YEAR WARRANTY ... 41
Add Comment
Terms and Conditions
These terms and conditions contain rules about posting comments. By submitting a comment, you are declaring that you agree with these rules:
- Although the administrator will attempt to moderate comments, it is impossible for every comment to have been moderated at any given time.
- You acknowledge that all comments express the views and opinions of the original author and not those of the administrator.
- You agree not to post any material which is knowingly false, obscene, hateful, threatening, harassing or invasive of a person's privacy.
- The administrator has the right to edit, move or remove any comment for any reason and without notice.
Failure to comply with these rules may result in being banned from further commenting.
These terms and conditions are subject to change at any time and without notice.
Comments