Informazioni
The T-Berd 211 is a portable test instrument that
comprehensively analyzes T1 and TIC transmission systems.
Used in the central office and in the field, the T-BERD 211
is used during circuit installation, acceptance testing, and
fault isolation. In the central office, the T-Berd 211 can
either generate and receive test patterns for out-of-service
testing or monitor T1 and TIC circuits without service
interruption. In the field, the instrument detects and
isolates problems related to customer-owned equipment (e.g.,
Customer Service Unit (CSU)) and detects problems
originating from the T1 span line; no CSU is required for
span line testing.
The T-Berd 211 offers these key features and characteristics:
(1) D4, ESF, and SLC*-96 framing patterns offer
compatibility with a variety of framing formats. An unframed
mode is also available for applications where framing is not
required.
(2) Summary Test Results category displays key non-zero and
“out- of-spec” results, eliminating the search through long
lists of test results.
(3) Automatic Configuration Mode lets the T-BERD 211
configure to the proper line rate (T1 or TIC), framing,
coding, and pattern. No set-up is required when monitoring
live circuits.
(4) Simultaneous Logic Error, Bipolar Violation, and Frame
Error Analysis with associated error rate, errored seconds,
and percent error-free seconds calculations.
(5) Signal Analysis with simplex current, signal level,
timing slip, and recovered clock frequency measurements.
(6) Jitter Analysis with jitter wideband and highband
measurements, and a Spectral Analysis option that displays
the relative amount of jitter as a percentage of a
specification mask. The T-Berd 211 also features a jitter
alarm LED that immediately illuminates when jitter is
present on the received T1 signal.
(7) Pulse Shape Analysis allows you to measure the height,
width, rise time, fall time, overshoot and undershoot of a
T1 pulse. Pulse shapes can also be measured for conformance
to AT&T Compatibility Bulletin 119 or ANSI T 1.403 Network
Interface specifications.
(8) Slips and Wander measurements identify wander
impairments or the potential for frame slips.
(9) Logic, BPV, and Frame Error Insertion enables the T-BERD
211 to simulate errors as they actually occur. Errors may be
inserted singly, in a burst, or at variable rates.
(10) RS-232 Printer/Remote Control Interface allows you to
print graphic displays (e.g., pulse shapes) and error
analysis results, and to remotely control the T-Berd 211,
(11) Results History Buffer stores up to 6 sets of your most
recent test results which can be viewed from the front panel
(12) All Zeros test pattern allows the T-Berd 211 to test
B8ZS and ZBTSI circuits where the zeros are encoded to meet
specification requirements limiting excess zeros. When
transmitting all zeros, the T-Berd 211 determines if the
circuit is capable of transporting B8ZS encoded data.
(13) Automated bridge tap detection test allows the T-BERD
211 to more thoroughly evaluate a T1 span for bridge taps.
The test automatically generates 21 test patterns which are
monitored for errors. The T-Berd 211 displays the cumulative
test results and which patterns experienced one or more bit
errors on the front panel. It also provides a RESULTS
printout which indicates the number of bit errors, errored
seconds, and pattern synchronization seconds for each pattern.
(14) Automated multipattern test simplifies testing by
generating five standard T1 test patterns in 15 minutes,
eliminating the need to perform individual tests with each
pattern. The T-Berd 211 displays the cumulative test results
for the test and which patterns experienced one or more bit
errors on the front panel. It also provides a RESULTS
printout which indicates the bit error, errored second, and
pattern synchronization second results for each pattern.
(15) Clear history and printer buffers function allows the
T-Berd 211 to clear the history and printer buffers of
stored results.
(16) Printer squelch function automatically suspends the
T-Berd 211 printouts when excessive alarm, error, and
severely errored second conditions occur during a test.
(17) Optional programmable long user pattern allows a 1- to
2000- character hexadecimal pattern to be transmitted to
determine circuit sensitivity to the pattern. The option
also provides a minimum/ maximum density stress pattern
selectable from the front panel PATTERN switch (MIN/MAX test
pattern).
(18) Optional T1 ZBTSI encoded Extended Superframe Mode
allows the T-Berd 211 to transmit and receive ZBTSI (Zero
Byte Time Slot. Interchange) encoded ESF framed T1 data. The
option also allows framing errors to be inserted in the ESFz
F-bits or Z-bits.
Tipo di manuale:
Manuale d'uso
Pagine:
122
Dimensione:
2.93 Mbytes (3072981 Bytes)
Lingua:
english
Revisione:
P
ID del manuale:
50-12257-01
Data:
1994 06 01
Qualità:
Documento scansionato, tutto leggibile.
Data caricamento:
2017 01 10
MD5:
a90a7503af9102bab3a1714c7dd26f1f
Scaricamenti:
1211
Informazioni
The T-Berd 209A.211 User’s Guide presents the most often
used T-Berd 209A.211 test setups in complete and concise
steps. Illustrations, helpful notes, and step-by-step
procedures make this manual a unique aid for novice and
experienced users alike.
If you are unfamiliar with the instrument, refer to the
T-BERD 209A/211 Reference Manual for more detailed
information. If you require additional help, call TTC
Customer Service at (800) 638-2049.
The user’s guide is divided into the following sections:
BASIC SETUPS — Describes setup procedures to generate
printouts and perform timed tests with the T-Berd 209A.211.
TESTING T1 NETWORKS—Describes several T-Berd 209A.211
standard applications. Each application describes how to
configure the T-Berd 209A.211 mainframe, connect to the
circuit being tested, and interpret the test results.
TDR TESTING — Provides instructions to set up and use the
TDR Option to identify and locate cable problems on XI span
cable sections.
ADVANCED TESTING — Describes setup procedures and results
interpretation for several T-Berd 209A.211 advanced options,
including the Enhanced ESF Option, FT1 Option, Channel
Monitor Option, and Advanced BERT Option.
TESTING NEWLY INSTALLED T1 SPANS —Presents applications that
use the T-BERD Repeater Power supply to power anew T1 span
and use the T-Berd 209A.211 to test the span. Each
application describes how to configure the T-BERD Repeater
Power Supply, configure the T-Berd 209A.211 mainframe,
connect to the circuit being tested, and interpret the test
results.
TESTING DIGITAL LOOP CARRIER (DLC) NETWORKS
Describes setup procedures and results interpretation for
testing DLC networks using the T-Berd 209A.211 DLC Analyzer
Lid Option.
Tipo di manuale:
Manuale d'uso
Pagine:
348
Dimensione:
1.19 Mbytes (1244627 Bytes)
Lingua:
english
Revisione:
P
ID del manuale:
50-10995-02
Data:
1994 06 01
Qualità:
Documento scansionato, tutto leggibile.
Data caricamento:
2017 01 10
MD5:
b7a5363256945dde8cf927413de47ddf
Scaricamenti:
940
Informazioni
The purpose of this reference manual is to provide
information about the physical features, functional
operation, and specifications of the Telecommunications
Techniques Corporation (TTC) T-Berd 209A and T-BERD 211
T-Carrier Analyzers.
This manual provides information on the following options
that are available for the T- BERD 209A and T-Berd 211,
• G.821 Performance Analysis Option (209A/211-1)
• Jitter Spectral Analysis Option (211-2)
• Rechargeable Lead-Acid Battery Option (209A-2)
• Advanced BERT Option (209A/211-3)
• Enhanced ESF Option (209A/211-4)
• Time Domain Reflectometer Option (209A/211-5)
• Fractional T1 Option (209A/211-6)
• T-BERD DLC Analyzer Option (209A/211-96)
• T-BERD T1 Channel Monitor Option (Model 40849)
• T-BERD Repeater Power supply Option (Model 41084)
In addition to this manual, a T-Berd 209A.211 User’s Guide
provides information on setting up and operating the T-BERD
209A and T-Berd 211 in a number of in-service and out-
of-service applications.
Tipo di manuale:
Manuale d'uso
Pagine:
276
Dimensione:
6.65 Mbytes (6968667 Bytes)
Lingua:
english
Revisione:
A
ID del manuale:
ML10995-02
Data:
1990 07 01
Qualità:
Documento scansionato, tutto leggibile.
Data caricamento:
2017 01 15
MD5:
d5ca4ca92545f3fd6daf3ad577a81349
Scaricamenti:
678
Informazioni
1.0
GENERAL INFORMATION ...
... 1-1
1.1
Introduction ...
... 1-1
1.2
Instrument
Overview ...
1-1
2.0
INSTRUMENT DESCRIPTION ...
... 2-1
2.1
Introduction ...
... 2-1
2.2
Controls, Indicators, and Connectors ...
... 2-1
2.3
Operating
Modes ...
... 2-17
2.4
Auxiliary
Functions ...
... 2-21
2.5
Test
Patterns ...
2.6
Measurements ...
2-58
3.0
PREPARATION FOR USE ...
... 3-1
3.1
Introduction ...
... 3-1
3.2
Unpacking ...
... 3-1
3.3
Equipment
Included ...
... 3-1
3.4
Instrument
Checkout ...
3-1
4.0
OPERATION ...
... 4-1
4.1
Introduction ...
... 4-1
4.2
T1
Testing ...
... 4-1
4.3
Simplex Current Measurement and CSU Emulation ...
... 4-11
4.4
Signal Level
Measurement ...
... 4-15
4.5
SLC-96
Testing ...
... 4-16
4.6
T1C
Testing ...
... 4-23
4.7
Multipat and Bridgtap
Testing ... ,
... 4-28
4.8
Measuring Timing Slips and Wander ...
... 4-31
4.9
Measuring Pulse
Shape ...
... 4-40
4.10
Measuring T1
Jitter ...
4-45
5.0
PRINTER/REMOTE CONTROL Interface ...
... 5-1
5.1
Introduction ...
... 5-1
5.2
Interface
Description ...
... 5-1
5.3
RS-232 Pin
Configuration ...
... 5-2
5.4
Printer
Operation ...
... 5-3
5.5
Remote Control
Operation ...
... 5-9
5.6
Remote Control Commands ...
... 5-19
6.0 MAINTENANCE AND
SERVICE ... 6-1
6.1
Introduction ... 6-1
6.2
Maintenance ... 6-1
6.3
Service ... 6-2
7.0
SPECIFICATIONS ... 7-1
7.1 Introduction
... 7-1
7.2 General
Specifications ... 7-1
7.3 Input
Specifications ... 7-1
7.4 Output
Specifications ... 7-2
7.5 Front
Panel ... 7-3
7.6 Pattern
Specifications ... 7-6
7.7 Loop
Codes ... 7-7
7.8
Measurements ... 7-8
7.9
Connectors ... 7-10
7.10
Grounding ... 7-12
8.0 OPTIONS AND Accessories
... 8-1
8.1
Introduction ... 8-1
8.2
Options ... 8-1
8.3
Accessories ... 8-2
Appendices
A. Discussion of
G.821 ... A-1
B.
References ... B-1
C. T-BERDT1 Channel Monitor
Option ... C-1
D. Jitter Masks
... , ... D-1
D. Jitter Masks
... D-1
E. Minimum/Maximum Stress
Pattern ... E-1
Add Comment
Terms and Conditions
These terms and conditions contain rules about posting comments. By submitting a comment, you are declaring that you agree with these rules:
- Although the administrator will attempt to moderate comments, it is impossible for every comment to have been moderated at any given time.
- You acknowledge that all comments express the views and opinions of the original author and not those of the administrator.
- You agree not to post any material which is knowingly false, obscene, hateful, threatening, harassing or invasive of a person's privacy.
- The administrator has the right to edit, move or remove any comment for any reason and without notice.
Failure to comply with these rules may result in being banned from further commenting.
These terms and conditions are subject to change at any time and without notice.
Comments