Tektronix SW503 Generatore
Produttore:
Modello:
SW503
Data:
1977
Categoria:
Gruppo:
Descrizione:
Sweep Generator Plug-In

Informazioni

The SW 503 is a TM 500-Series Plug-In that provides a swept frequency of 1 MHz to 400 MHz with variable sweep rate, width, and output level. Crystal-controlled harmonic oscillators provide comb markers with 1 MHz, 10 MHz, or 50 MHz separation. When used with a DC 502 Option 7 Digital Counter, a frequency markerdot can be positioned anywhere within the frequency range of the SW 503 Generator, and the frequency of the marker can be read directly on the Counter. In the Manual sweep and CW modes, the continuous wave output of the Generator can be read to the Counter accuracy. Access jacks on the front panel permit external signals to control or modulate the output amplitude and frequency, and to initiate a sweep. The SW 503 has a 50 Ω output impedance; the SW 503 Option 1 has a 75 Ω output impedance.

mostra più dettagli

Servizio e manuale utente
Tipo di manuale:
Servizio e manuale utente
Pagine:
60
Dimensione:
14.65 Mbytes (15358714 Bytes)
Lingua:
english
Revisione:
ID del manuale:
Data:
1977 01 01
Qualità:
Documento scansionato, tutto leggibile.
Data caricamento:
2017 12 27
MD5:
a0cb54ab692f39756737aebba20557fc
Scaricamenti:
627

Informazioni

Section 1 DESCRIPTION Page 1.1 INTRODUCTION 1-1 1.2 ELECTRICAL CHARACTERISTICS 1-1 1.3 ENVIRONMENTAL CHARACTERISTICS 1-2 Section 2 OPERATION 2.1 FRONT PANEL CONTROLS AND CONNECTORS 2-1 2.2 OPERATING INSTRUCTIONS AND NOTES 2-4 2.2.1 General Setup and First-Time Operation 2-4 2.2.2 Cable Connections 2-5 2.2.3 Impedance Matching 2-5 2.2.4 Detecting (Demodulating) 2-5 2.2.5 Sweep Rate Effects 2-6 2.2.6 Overloading Effects 2-6 2.2.7 Low-Level Measurements 2-6 2.2.8 TV Receiver Interference 2-6 2.2.9 Use with Digital Counter 2-6 2.2.10 Operation with X-Y Plotters 2-6 2.3 EXTERNAL CONTROL 2-7 2.3.1 Frequency Control 2-7 2.3.2 Amplitude Control 2-7 2.3.3 Trigger Control 2-7 The remainder of this table of contents refers to servicing instructions which should be performed by qualified personnel only. Section 3 CALIBRATION 3.1 INTRODUCTION 3-1 3.2 EQUIPMENT REQUIRED 3-1 3.3 PRELIMINARY STEPS 3-2 3.4 PROCEDURE 3-2 Section 4 CIRCUIT DESCRIPTION 4.1 GENERAL 4-1 4.2 SWEEP RAMP GENERATOR 4-1 4.2.1 Basic Operation 4-1 4.2.2 Ramp Generator 4-2 4.2.3 Single Sweep 4-2 4.2.4 Line Rate 4-3 4.2.5 CW Mode 4-3 4.2.6 MANual Mode 4-3 Section 4 CIRCUIT DESCRIPTION (cont) Page 4.3 SWEEP DRIVE CIRCUITRY 4-3 4.3.1 Input Adder 4-3 4.3.2 Ramp Shading Network 4-3 4.3.3 4.3.3 Output Amplifier 4-5 4.4 SWEEP Oscillator MODULE 4-5 4.5 RF Oscillator MODULE 4-5 4.6 HARMONIC MARKER MODULE 4-7 4.7 MARKER AMPLIFIER 4-7 4.8 COUNTER INTERFACE 4-9 Section 5 IMPLEMENTING SPECIAL FEATURES 5.1 CHANGING HORIZONTAL OUTPUT VOLTAGE 5-1 5.2 INTERFACE THROUGH REAR CONNECTOR 5-1 5.2.1 Introduction 5-1 5.2.2 Mainframe Modification 5-1 5.2.3 Vertical Output and Horizontal Output 5-1 5.2.4 External Frequency Control or Modulation 5-2 5.2.5 External Amplitude Control or Modulation 5-2 5.2.6 External Trigger 5-2 5.2.7 Digital Counter Interface 5-3 Section 6 REPLACEABLE ELECTRICAL PARTS OPTIONS Section 7 DIAGRAMS AND CIRCUIT BOARD ILLUSTRATIONS Section 6 REPLACEABLE MECHANICAL PARTS CHANGE INFORMATION

mostra più dettagli

Servizio e manuale utente
Tipo di manuale:
Servizio e manuale utente
Pagine:
68
Dimensione:
5.36 Mbytes (5618490 Bytes)
Lingua:
english
Revisione:
ID del manuale:
Data:
1977 01 01
Qualità:
Documento scansionato, tutto leggibile.
Data caricamento:
2017 12 25
MD5:
b150c09dc31a1902d1525b14541947d6
Scaricamenti:
445

Informazioni

Section 1 DESCRIPTION Page 1.1 INTRODUCTION 1-1 1.2 ELECTRICAL CHARACTERISTICS 1-1 1.3 ENVIRONMENTAL CHARACTERISTICS 1-2 Section 2 OPERATION 2.1 FRONT PANEL CONTROLS AND CONNECTORS 2-1 2.2 OPERATING INSTRUCTIONS AND NOTES 2-4 2.2.1 General Setup and First-Time Operation 2-4 2.2.2 Cable Connections 2-5 2.2.3 Impedance Matching 2-5 2.2.4 Detecting (Demodulating) 2-5 2.2.5 Sweep Rate Effects 2-6 2.2.6 Overloading Effects 2-6 2.2.7 Low-Level Measurements 2-6 2.2.8 TV Receiver Interference 2-6 2.2.9 Use with Digital Counter 2-6 2.2.10 Operation with X-Y Plotters 2-6 2.3 EXTERNAL CONTROL 2-7 2.3.1 Frequency Control 2-7 2.3.2 Amplitude Control 2-7 2.3.3 Trigger Control 2-7 WARNING I The remainder of this table of contents refers to servicing instructions which should be performed by qualified personnel only. Section 3 CALIBRATION 3.1 INTRODUCTION 3-1 3.2 EQUIPMENT REQUIRED 3-1 3.3 PRELIMINARY STEPS 3-2 3.4 PROCEDURE 3-2 Section 4 CIRCUIT DESCRIPTION 4.1 GENERAL 4-1 4.2 SWEEP RAMP GENERATOR 4-1 4.2.1 Basic Operation 4-1 4.2.2 Ramp Generator 4-2 4.2.3 Single Sweep 4-2 4.2.4 Line Rate 4-3 4.2.5 CW Mode 4-3 4.2.6 Manual Mode 4-3 Section 4 CIRCUIT DESCRIPTION (cont) Page 4.3 SWEEP DRIVE CIRCUITRY 4-3 4.3.1 Input Adder 4-3 4.3.2 Ramp Shading Network 4-3 4.3.3 4.3.3 Output Amplifier 4-5 4.4 SWEEP Oscillator MODULE 4-5 4.5 RF Oscillator MODULE 4-5 4.6 HARMONIC MARKER MODULE 4-7 4.7 MARKER AMPLIFIER 4-7 4.8 COUNTER INTERFACE 4-9 Section 5 IMPLEMENTING SPECIAL FEATURES 5.1 CHANGING HORIZONTAL OUTPUT VOLTAGE 5-1 5.2 INTERFACE THROUGH REAR CONNECTOR 5-1 5.2.1 Introduction 5-1 5.2.2 Mainframe Modification 5-1 5.2.3 Vertical Output and Horizontal Output 5-1 5.2.4 External Frequency Control or Modulation 5-2 5.2.5 External Amplitude Control or Modulation 5-2 5.2.6 External Trigger 5-2 5.2.7 Digital Counter Interface 5-3 Section 6 REPLACEABLE ELECTRICAL PARTS OPTIONS Section 7 DIAGRAMS AND CIRCUIT BOARD ILLUSTRATIONS Section 8 REPLACEABLE MECHANICAL PARTS CHANGE INFORMATION

mostra più dettagli