Philips PM3551A/10 Analizzatore logico
Produttore:
Modello:
PM3551A/10
Data:
1983
Categoria:
Gruppo:
Descrizione:

Informazioni

The PM3551A/70 is capable of recording a maximum of 59 state channels and 8 50MHz timing channels while the PM3551A/30 although identical in design and operation is capable of measuring a maximum of 35 state channels and 8 50MHz timing channels. The PM3551A/10 and PM3551A/50 have the same features as the above mentioned PM3551A/30 and PM3551A/70 models with the exception of the "50MHz Timing Analyzer*' mode. The operator control panel is divided into several functional areas which guide and help the user to set up the most effective test procedure. A functionally organized keyboard/softkey structure in combination with an interactive menu-display serve the user in setting up and entering parameters for triggering, capturing, comparing and counting the activities of the system under test. The extensive triggering capability of the 7 sequential trigger-words, that can be combined with clock and trigger-qualifiers, permits capturing data from complex system activities or from deep branched or nested loops. Each trigger-word has the same width as the number of input channels of the various models. The sequence of the different trigger-words used can be defined by the use of an IF, THEN, ELSE algorithm, with the possibility of placing a certain amount of delay between the statements. In this mode triggering can be selected as True or False. A notable feature of this mode is that the selected trigger sequence can be specified as true or alternatively as not true. This latter mode is called "Trigger on Sequence Break" mode and provides the capability of triggering when a defined repetitive pattern (eg. a loop or a polling sequence) is broken or not executed in the specified order. The moment of capturing data can be delayed by states and/or trigger occurrences and/or time. The Logic Analyzer can also be used for making time measurements * A readout of the elapsed time between two points in a program can be obtained. Special features of note here are the COMBI and the SYNC modes. The COMBI mode allows the state section to be triggered by the timing section or vice-versa, while in the SYNC mode the displays of a number of timing channels are cross-referenced with state sampling. This enables analysis of critical state/time relationships. Data to be captured is clocked into the Analyzer on selected clock edges of one of the three selectable clock sources. For each clock used, there are up to four qualifiers available. In the COMPARE mode, a comparison can be made between captured data and stored data in the formats: List or Timing. The instrument automatically stores the current mode- and function instrument-setting, when the mains voltage supply is switched off. After switching on, the instrument comes up in the initial default mode- and function setting. All Analyzer models can be equipped with the option (non-volatile memory) to store up to 4 additional settings. Here each setting is stored and retrieved under a label. In the TIMING mode, glitches of a duration of as little as 5 nanoseconds can be captured from the data-stream. The PM 3551A can be equipped with a 4 channel 300MHz timing option, independently of the presence of the 8 channel 50 MHZ section. This allows high precision timing measurements. Other options are the options board with standard RS232C printer output. This board can be equipped with an GPIB control Interface, or a RS232C control Interface, both providing full remote control of the instrument. The options board is also a prerequisite for installation of disassembly- packages, and the non-volatile setting memory. The disassembly-packages allow the user to view captured data in the mnemonic language of the most currently available 8 and 16-bit microprocessors• Data is entered into the Analyzer via 8-channel pods, each provided with its own threshold adjustment. A variety of convenient Pod-attachments are available for connecting the system under test to the Analyzer. A comprehensive built-in diagnostic program can be used as an aid to test the various functions of the Analyzer and to assist in fault-finding.

mostra più dettagli

Manuale d'uso
Tipo di manuale:
Manuale d'uso
Pagine:
202
Dimensione:
18.98 Mbytes (19901409 Bytes)
Lingua:
english
Revisione:
ID del manuale:
9499 500 12911
Data:
1983 10 13
Qualità:
Documento scansionato, tutto leggibile.
Data caricamento:
2017 01 29
MD5:
018d62b73d89e31c43aea1a17bf4f7fc
Scaricamenti:
2468

Informazioni

1 INTRODUCTION ... 1.4 1.1 General information ... 1.4 1.2 Features ... 1.5 2 CHARACTERISTICS ... 2.1 2.1 Logic State Analyzer ... 2 .4 2.2 Logic Timing Analyzer. ... 2.9 2.3 Operation ... 2 .11 2.4 Display ... 2.11 2.5 Display modes ... 2.12 2.6 Compare mode ... 2 .13 2.7 Power supply ... 2.13 2.8 Environmental characteristics ... 2 .14 2.9 Physical characteristics ... 2 .16 2.10 Accessories and Options ... 2.17 3 GENERAL DIRECTIONS ... 3.1 3.1 Information and Warnings for the User ... 3 .2 3.2 Description of controls, connectors and display ... .12.1 13 PROBLEM REPORTS AND CHANGE REQUESTS ... 13.1

mostra più dettagli