Kikusui Electronics Corporation PLZ-150W Altro
Produttore:
Modello:
PLZ-150W
Data:
0
Categoria:
Gruppo:
Descrizione:
ELECTRONIC LOAD

Informazioni

Series PLZ-W Electronic Loads can be operated in constant resistance mode, constant current mode and switching action electronically, replacing the conventional sliding resistors (rheostats). Major features of the PLZ-W series are as follows: 1. Digital Meters. A digital voltmeter and an ammeter with an auto range of 3 1/2 digits. 2. A 1O-Turn Multi-Dial. Current values and resistance values may be set very precisely with the 10 turn multi-dial having a lock mechanism. 3. Function of Presetting. Current and resistance values may be preset. A. Built-in Oscillator for Switching Action. To be used in the constant current mode. Switching action occurs within the frequency range of 10 Hz - 1 kHz. 5. Display of Loading Power. Supplied power value is displayed in a digital figure and in the form of luminescent bar graph. 6. Remote Control Functions. When operated in the constant current mode the instrument may be remotely controlled by either an external voltage or an external resistance. The instrument may also be remotely controlled by an external resistance when operated in the constant resistance mode. 7. One-controlled Parallel Operation. It is possible to increase current capabilities by operating a number of units connected in parallel simultaneously under the control of a master unit. 8. Protection Circuits Include: Overvoltage, overcurrent, overpower, overheating, and input terminal connection in reverse polarity. The PLZ series is offered as a portable desk-top unit and may be integrated into a 19 inch or 500 mm Kikusui standard rack, with the use of the option brackets» 1-2. Specifications Power Requirements. Line voltage: 120 V AC i 10% 50/60 Hz single phase Power consumption: Approx. 35 VA (at 120 V AC) Input. Loading voltage: 4 - 60 V DC. Loading current: 0 - 30 A Maximum loading power: 150 W Operating ambient temperature range: Ö - 40°C (32 - 104°F) Operating ambient humidity range: 10% - 90% RH Cooling method: Forced air cooling by means of fan Isolation from ground: ±250 V DC Modes. Constant current mode: 0 - 30 A (1st range) 0 - 3 A (2nd range) .Constant resistance mode: 10 - 100 τηΩ (1st range) (minimum 0.12 Ω) 0.1 - 1 Ω (2nd range) 1 - 10 Ω (3rd range) 10 - 100 Ω (4th range)

mostra più dettagli

Servizio e manuale utente
Tipo di manuale:
Servizio e manuale utente
Pagine:
52
Dimensione:
1.52 Mbytes (1597429 Bytes)
Lingua:
english
Revisione:
ID del manuale:
Data:
Qualità:
Documento scansionato, la lettura in parte male, non in parte leggibile.
Data caricamento:
2015 08 14
MD5:
a84839480af9a1a2f65acb4a54eb62de
Scaricamenti:
604

Informazioni

SECTION 1. GENERAL ... 1 1-1. Introduction ... 1 1-2. Specifications ... 2 SECTION 2. OPERATION ... 5 2-1. Notes Before Operation ... 5 2-2. Front and Rear Panel Descriptions ... 10 2-3. Initial Setting ... 13 2-4. Operation in the Constant Resistance Mode ... 14 2-5. Use of nxl0" Range in the Constant Resistance Mode ... 17 2-6. Graph of Resistance Range and Power Limit Relation ... 18 2-7. Operation in the Constant Current Mode ... 20 2-8. Operation in the Switching Mode ... 22 2-9. Operation in the Constant Voltage Mode ... 24 2-10. Indication of Loading Power ... .. 27 2-11. Presetting the Power Lindt ... 28 2-12. Remote Control with an External Resistance (Constant Resistance or Constant Current) ... 29 2-13. Remote Control with an External Voltage (Constant Current only) ... 30 2-14. Remote Control of Load Switch by an External Terminal ... 31 2-15. One-control Parallel Operation ... 31 SECTION 3. OPERATING PRINCIPLES ... 34 3-1. Constant Current Operation ... 34 (j> 3-2. Constant Resistance Operation ... 34 ^ 3-3. Block Diagram ... 36 SECTION 4. MAINTENANCE ... 37 4-1. How to Open the Chassis Case ... . 37 4-2. Inspections and Cleaning ... 37 4-3. Calibration ... 38

mostra più dettagli