Keithley 7999-6 Interfaccia
Manufacturer:
No picture available!
Maybe you can upload a pic for the
Keithley 7999-6 ?
If you have any other manuals for the
Keithley 7999-6 you can upload the files here .
Model:
7999-6
Date:
2001
Category:
Group:
Description:
GPIB RF Relay Unit
Information
The Model 7999-6 is an IEEE-488 controlled, single or dual, 4 or 6 pole, 19-inch rack
mounted relay unit. Additional features of the Model 7999-6 are as follows:
• N-type bulkhead connectors (insulated)
• +24VDC power connections
• LED indicators for error, power, and relay status
• Operating range to 4GHz (relay dependent)
• Can be upgraded from 4-pole to 6-pole relays
Manual type:
Servizio e manuale utente
Pages:
87
Size:
1.40 Mbytes (1465105 Bytes)
Language:
english
Revision:
A
Manual-ID:
7999-6-901-01
Date:
Quality:
Documento elettronico, senza ricerca, molto ben leggibile.
Upload date:
02 March 2014
MD5:
eda9430778a16daf86eaac26278b6410
Downloads:
572
Information
1 General Information
Introduction
...
1-2
Feature overview
...
1-2
Warranty information
...
1-2
Manual addenda
...
1-2
Safety symbols and terms
... 1-3
Specifications
...
1-3
Unpacking and inspection
... 1-3
Inspection for damage
... 1-3
Handling precautions
... 1-3
Shipment contents
...
1-4
Instruction manual
...
1-4
Repacking for shipment
... 1-4
Connections
...
1-4
2 Connections
Introduction
...
2-2
Handling precautions
...
2-2
Configuration
...
2-2
Layout
...
2-2
Simplified schematic
... 2-4
Connections
...
2-5
GPIB control connection
... 2-5
Power connector
...
2-8
3 Operation
Introduction
...
3-2
Maximum signal considerations
... 3-2
Bus operation (GPIB)
...
3-3
Bus connections
...
3-3
Primary address
...
3-3
Programming syntax
... 3-3
Response messages
... 3-7
Status model
...
3-8
Event register sets
... 3-10
Enable registers
...
3-11
Queues
...
3-11
Status byte and SRQ
... 3-13
Service request enable register
... 3-14
Serial polling and SRQ
... 3-15
Clearing registers and queues
... 3-16
Programming enable registers
... 3-17
Reading registers
...
3-17
Common commands
...
3-18
GPIB commands
...
3-26
ROUTe commands
...
3-26
:CLOSe ...
3-28
:CONFigure ...
3-29
STATus commands
...
3-30
:QUEue ...
3-30
SYSTem commands
... 3-32
Manual operation
...
3-34
Switching considerations
... 3-35
Connector integrity
...
3-35
Voltage Standing Wave Ratio
... 3-35
Path isolation
...
3-36
Insertion loss
...
3-36
RFI/EMI
...
3-36
Errors
...
3-37
4 Service Information
Introduction
...
4-2
Handling and cleaning precautions
... 4-2
Handling precautions
... 4-2
Card and connector cleaning
... 4-2
Performance verification
... 4-3
Environmental conditions
... 4-3
Recommended equipment
... 4-3
Channel resistance tests
... 4-3
Replacing components
...
4-4
Replacement parts
...
4-4
Replacement precautions
... 4-5
Soldering considerations
... 4-5
Relay replacement
...
4-5
Circuit board removal
... 4-8
GPIB address
...
4-8
5 Replaceable Parts
Introduction
...
5-2
Parts list
...
5-2
Ordering information
...
5-2
Factory service
...
5-2
Component layout
...
5-2
Add Comment
Terms and Conditions
These terms and conditions contain rules about posting comments. By submitting a comment, you are declaring that you agree with these rules:
- Although the administrator will attempt to moderate comments, it is impossible for every comment to have been moderated at any given time.
- You acknowledge that all comments express the views and opinions of the original author and not those of the administrator.
- You agree not to post any material which is knowingly false, obscene, hateful, threatening, harassing or invasive of a person's privacy.
- The administrator has the right to edit, move or remove any comment for any reason and without notice.
Failure to comply with these rules may result in being banned from further commenting.
These terms and conditions are subject to change at any time and without notice.
Comments