Good Will LCR-816 Metro di LCR
Produttore:
Nessuna immagine disponibile!
Forse puoi caricare una foto per la
Good Will LCR-816?
Se avete altri manuali per la
Good Will LCR-816 potete caricare i file qui .
Modello:
LCR-816
Data:
Categoria:
Gruppo:
Descrizione:
Informazioni
The precise LCR Meter series are automatic, user
programmable instruments
that provide high reliability and great precision for
measuring a wide variety of
impedance parameters. The frequency range of LCR-819.829
covers from 12Hz
to 100kHz, LCR-817.827 from 12Hz to 10kHz, LCR-816.826 from
100Hz to
2kHz, and LCR-821 from 12Hz to 200kHz. The basic accuracy is
0.1% for LCR-
827/829/816/826, 0.05% for LCR-817.819/821. The measured
results can be
displayed on the high quality LCD monitor with decimal
points and units. The
measured result resolution is five full digits for
Inductance (L), Capacitance (C),
Resistance (R) and absolute value of impedance (|Z|)
[four full digits for
Dissipation factor (D), Quality factor (Q), R with C, R with
L, 2 digits after
decimal dot for phase angle (θ)]. In the meantime, the LCD
monitor is also shown
the control status and parameters of settings. The keypads
are easy for menu
programming. The LCR Meters’ test fixture (option) is a
method of convenient,
reliable, guarded 4-terminal/2 wires connection of radial
and axial leaded
components to the LCR Meters. Test conditions can be stored
and recalled from
internal memory that will reduce the setup time for
measurement preparing.
Tipo di manuale:
Manuale d'uso
Pagine:
40
Dimensione:
710.70 Kbytes (727758 Bytes)
Lingua:
english
Revisione:
ID del manuale:
Data:
Qualità:
Documento elettronico, senza ricerca, molto ben leggibile.
Data caricamento:
2017 05 14
MD5:
5b7be1d872d18f20b2abe2481e9b2779
Scaricamenti:
2892
Informazioni
1.
INTRODUCTION ...
1
2.
3.
4.
PRECAUTIONS BEFORE OPERATION ...
2-1.Unpacking the
instrument ...
2-2.Checking the Line
Voltage ...
2-3.Environment ...
2-4.Equipment Installation and Operation ...
PANEL DESCRIPTION ...
OPERATION ...
4-1.Connects to
DUT ...
4-2.Start-Up ...
4-3.Zeroing ...
4-4.Menu
Functions ...
4-5.Measurement
Conditions ...
2
2
2
3
3
4
8
8
8
8
11
18
5.
SPECIFICATIONS ... 35
6.
MESSAGE
CODE ... 44
7.
MAINTENANCE ...
45
7-1.Cleaning ...
45
7-2.Battery
Replacement ...
45
7-3.Recall
Calibration ...
46
8.
OPTION 1 (BIN Function for LCR-826.827/829 only) ...
48
8-1. BIN Functions for Components Sorting ...
48
8-2. BIN Setting
Conditions ...
50
8-3. BIN Range Setting: Component Sorting Range ...
56
9.
OPTION
2 ...
9-1.On-line
procedure ...
9-2.RS232 VIEWER Software Operation ...
9-3.The Configuration of
Cable ...