opweb.de

L'archivio per il download gratuito di manuali e manuali di servizio manuali


Cosa stai cercando?


Hewlett Packard - 8601A - Generatore
Fabricante:
Equipaggiamento:
8601A
Data:
1969
Categoria:
Gruppo:
Sottogruppo:

Informazioni

The Model 8601A Generator weeper is a rf signal source with both CW and wide band swept frequency capabilities in the 0.1 to 110 MHz range. In the CW mode, residual fm is less than 50 Hz rms from 0.1 to 11 MHz, and less than 500 Hz rms from 1.0 to 110 MHz (including line-related components). Harmonic outputs are 35 dB below the carrier; spurious and non-harmonic outputs are 40 dB below the carrier. Swept-frequency measurements of all or any part of the 0.1 to 11 MHz or 1.0 to 110 MHz bands are possible by selection of FULL, VIDEO, or SYMMETRICAL sweep modes. Internal and external frequency modulation is also possible for narrow-band sweep operations or remote tuning. The FULL sweep covers the whole 0.1 to 11 MHz or 1.0 to 110 MHz band. The VIDEO sweep is from the bottom of the selected range up to the frequency selected by front panel frequency control. The SYMMETRICAL sweep operation sweeps above and below the CW frequency selected by front panel frequency control. The symmetrical sweep width is calibrated from 0.01 to 1.0 MHz for the 0.1 to 11 MHz band, and from 0.1 to 10 MHz for the 1.0 to 110 MHz band. A sweep width vernier adjusts the sweep width from the calibrated position to zero. The calibrated rf output is variable from +20 to -110 dBm (2.23V to 1 µVrms) into 50 ohms by use of the OUTPUT LEVEL and VERNIER controls. Other outputs include a 0.1 to 11 MHz auxiliary output on both bands to permit use of a low Frequency counter for frequency monitoring; a 0 to +7V sweep output for horizontal drive of Oscilloscope and X-Y recoders; and an uncalibrated rf output for phase-lock operations.

mostra più dettagli

1 Manuale

Manuale di servizio e utente
Tipo di manuale:
Manuale di servizio e utente
Pagine:
197
Dimensione:
11,2 MB
Lingua:
inglese
Revisione:
ID manuale:
08601-90017
Data:
Giugno 1971
Qualità:
Documento scansionato, che si legge in parte male, in parte non si legge.
Data caricamento:
07 Giugno 2020
MD5:
3f86e619-d49b-0771-8162-1634044191d2

Informazioni

Serial Prefix 969- This manual applies directly to HP Model 8601A Generator weepers having serial prefix number 969-. Serial Prefixes Not Listed For serial prefixes above 969-, a “Manual Changes” sheet is included with this manual. For serial prefixes below 969-, see Section VII, Manual Changes. I GENERAL INFORMATION ... . 1-1 1-1. Introduction ... . 1-1 1-3. Instruments Covered by Manual . 1-1 1-6. Description ... . 1-1 1-10. Options Available ... . 1-1 1-19. Recommended Test Equipment . 1-2 II INSTALLATION... . 2-1 2-1. Initial Inspection ... . 2-1 2-2. Mechanical Check ... . 2-1 2-4. Electrical Check ... . 2-1 2-6. Claims for Damage ... . 2-1 2-8. Preparation for Use ... . 2-1 2-9. Power Requirements ... . 2-1 2-11. 115/230 Volt Operation . . . 2-1 2-13. Three-Conductor Power Cable 2-1 2-15. Operating Environment . . . . 2-1 2-17. Bench Operation ... . 2-1 2-19. Repackaging for Shipment . . . 2-1 2-20. Original Packing Materials . 2-1 .2-22. Other Packing Materials . . . 2-2 Ill OPERATION ... . 3-1 3-1. Introduction ... . 3-1 3-3. Panel Features ... . 3-1 3-5. Operator’s Check... . 3-1 3-7. Operating Instructions ... . 3-1 3-9. General Operating Information 3-1 3-14. FM and Symmetrical Opera- tion ... . 3-1 3-17. Amplitude Modulation Opera- tion ... . 3-1 3-20. Operator’s Maintenance ... 3-13 3-21. Fuses ... 3-13 3-24. Lamp Replacement... 3-13 IV PERFORMANCE TESTS ... . 4-1 4-1 Introduction ... . 4-1 4-3. Equipment Required ... . 4-1 4-5. Test Record ... . 4-1 4-8. Frequency Coverage/Accuracy 4-2 4-9. Sweep Characteristics ... . 4-3 4-10. Linearity :... . 4-5 4-11. Amplitude Modulation . . . . 4-7 4-12. External FM ... . 4-9 4-13. Internal FM ... 4-12 4-14. Residual and Incidental FM . 4-15 4-15. Residual AM ... 4-17 4-16. Incidental AM ... 4-18 4-17. Output Level ... 4-21 4-18. Harmonics and Spurious Signals ... 4-22 V ADJUSTMENTS ... 5-1 5-1. Introduction ... 5-1 5-3. Equipment Required ... 5-1 5-5. Factory Selected Components . 5-1 5-7 Power Supply Adjustment . 5-4 5-8. Crystal Oscillator Adjustment . 5-4 5-9. VTO Adjustment... 5-5 5-10. Loop Amplifier Adjustment . 5-6 5-11. Discriminator and DC Amplifier Adjustments ... 5-6 5-12. ALC Balance Adjustment . . . 5-7 5-13. Modulation Rate Adjustment . 5-9 5-14. FM Adjustment ... 5-9 5-15. AM Adjustment ... 5-11 5-16. Meter Adjustment ... 5-12 5-17. Buffer Adjustment ... 5-13 5-18. Dwell Time Adjustment . . 5-14 5-19. Symmetrical Sweep Center Frequency Adjustment 5-14 5-20. Sweep Width Adjustment . . 5-15 VI REPLACEABLE PARTS ... 6-1 6-1. Introduction ... 6-1 6-6. Ordering Information... 6-1 VII MANUAL CHANGES ... 7-1 7-1. Introduction ... 7-1 VIII SERVICE ... 8-1 8-1. Introduction ... 8-1 8-3. Principles of Operation ... 8-1 8-5. Troubleshooting ... 8-1 8-7. Recommended Test Equipment . 8-1 8-9. Repair... 8-1 8-10. Part Location Aids ... 8-1 8-12. Circuit Board Repair ... 8-1 8-15. Component Replacement . . . 8-1 8-17. Transistor Replacement . . . . 8-2 8-19. Schematic Diagrams ... 8-2 8-25. Operation ... 8-4 8-27. Primary Signal Path ... 8-4 8-29. ALC Feedback Loop ... 8-4 8-31. Frequency Control Feedback Loop... 8-4 8-35. Frequency Tuning Control . 8-4

mostra più dettagli

Downloads:
453
Download hewlett-packard--8601a--service-user--ID12917.pdf