Tektronix DC 504 Contatore
Produttore:
Modello:
DC 504
Data:
1984
Categoria:
Gruppo:
Descrizione:
Counter/Timer

Informazioni

The DC 504 Counter/Timer measures frequency from 0.1 Hz (0 Hz with 0.1 Hz resolution) to at least 80 MHz. It measures period from 1"s to 999.99 s, and totalizes events from 0 to 99,999 at a maximum rate of at least 80 MHz. A resolution of 0.1 Hz can be obtained by allowing the more significant figures of the Counter to overflow. Five 7-segment light-emitting diodes (LED) provide a highly visible numerical display. The decimal point is automatically positioned and leading zeros (to the left of the most significant digit or decimal point) are blanked. Digit overflow is indicated by a front-panel LED. Signals to be counted or timed can be applied to either a front-panel bnc connector or to the rear Interface connector. The DC 504 is designed to operate in any of the TM 500-Series Power Modules. It is completely compatible with other members of the TM 500 family in terms of signal interconnections. The DC 504 is designed to operate in ambient temperatures between 0°Cand +50° C. It can be stored in temperatures ranging from -40°Cto 4-75° C. After storage in temperatures outside the specified operating temperatures, allow the DC 504 to return to a room ambient temperature within the operating range before applying power.

mostra più dettagli

Servizio e manuale utente
Tipo di manuale:
Servizio e manuale utente
Pagine:
59
Dimensione:
14.09 Mbytes (14776102 Bytes)
Lingua:
english
Revisione:
revised
ID del manuale:
070-1670-01
Data:
1984 12 01
Qualità:
Documento scansionato, tutto leggibile.
Data caricamento:
2017 12 30
MD5:
f8f8a53921c5448eaefa176beb8356c2
Scaricamenti:
669

Informazioni

Page OPERATORS PART—ENGLISH OPERATING INSTRUCTIONS INSTRUMENT DESCRIPTION ... PREPARATION FOR USE ... Installation and Removal ... Controls and Connectors ... INPUT CONSIDERATIONS ... Input Sources ... Triggering ... 1-4 Measurement Intervals ... 1-4 Maximum Input Volts, Sensitivity, and Frequency ... Range ... Setting Slope and Level ... 1-4 APPLICATIONS ... Frequency Measurements ... 1-6 Revolutions Per Minute (RPM) Measurements ... Totalizing ... Period Measurements ... FUNCTIONS AVAILABLE AT REAR Interface CONNECTOR CONTROL LINES ... Signal Lines ... Section 2 SPECIFICATION AND PERFORMANCE CHECK 2-1 Performance Conditions ... 2-1 Table 2-1.Electrical Characteristics . 2-1 Table 2-2. Environmental Characteristics ... 2-3 Performance Check ... 2-4 Section 3 ADJUSTMENT ... 3-1 Section 4 MAINTENANCE ... 4-1 Section 5 CIRCUIT DESCRIPTION ... 5-1 Section 6 REPLACEABLE ELECTRICAL PARTS LIST ... 6-1 OPTIONS Section 7 DIAGRAM AND CIRCUIT BOARD ILLUSTRATION ... 7-1 Section 8 REPLACEABLE MECHANICAL PARTS LIST AND EXPLODED VIEW ... 8-1 CHANGE INFORMATION

mostra più dettagli