Tektronix CSA8000 Communications Test Set
Produttore:
Modello:
CSA8000
Data:
Categoria:
Gruppo:
Descrizione:
Communications Signal Analyzer

Informazioni

The instrument is a high-speed, precision sampling system that finds use in: - high-performance semiconductor/computer applications, such as semiconductor testing, TDR characterization of circuit boards, IC packages and cables, and high-speed serial digital data communications. - high-performance communications applications, such as design evaluation and manufacturing test of datacom and telecom components, transceiver subassemblies, and transmission systems. The instrument includes a user Interface that runs on the Microsoft Windows 98 operating system as a windowed application. You operate the instrument using front-panel Controls with the mouse and keyboard or with the touch screen. Key features include: industry-leading waveform acquisition rate, with Sample, Envelope, and Average acquisition modes. support for up to six sampling modules for a maximum configuration of ten inputs. (Up to eight inputs can be active at a time. See Maximum Configuration on page 1–10). full programmability, with an extensive GPIB-command set and a messagebased Interface. true differential TDR, with fast step (35 psec reflected risetime) when used with a TDR-capable sampling module. negligible long-term jitter degradation (<0.1 ppm), which substantially improves the ability to view signals that are far delayed from the trigger point without distortion. industry-leading trigger bandwidth (12+ GHz) when using the built-in-pres-caler. support of both telecom (SONET and SDH) and datacom (Fibre Channel and Gigabit Ethernet) optical communication standards. powerful built-in measurement capability, including histograms, mask testing, and automatic measurements. Automatic measurements include eye/communications measurements, such as Q factor, extinction ratio, and optical power and general-purpose measurements, such as jitter and noise. DC to 50 GHz optical bandwidth; DC to 50 GHz electrical bandwidth, with up to 12.5 GHz triggering. FrameScan acquisition for isolating data-dependent failures during conformance/performance testing and for examining very low-level repetitive signals. support for optical conformance testing of SONET/SDH signals from 622 Mbps to 10.66 Gbps and for Fibre Channel 1063 and Gigabit Ethernet signals. a large 10-inch color display that supports color grading of waveform data to show sample density. an intuitive UI (User Interface), with built-in online help displayable on screen.

mostra più dettagli

Manuale di servizio
Tipo di manuale:
Manuale di servizio
Pagine:
354
Dimensione:
7.08 Mbytes (7419553 Bytes)
Lingua:
english
Revisione:
ID del manuale:
071-0438-01
Data:
Qualità:
Documento elettronico, senza ricerca, molto ben leggibile.
Data caricamento:
2017 12 25
MD5:
66b44c10976a5fc16f100489ff387973
Scaricamenti:
1102

Informazioni

This is the service manual for the CSA8000 Communications Signal Analyzer, TDS8000 Digital Sampling Oscilloscope and the sampling and other modules that install in both instruments. Read this preface to learn how this manual is structured, what conventions it uses, and where you can find other information related to servicing this product. Read the Introduction following this preface for safety and other important background information needed before using this manual for servicing this product.

mostra più dettagli

Manuale d'uso
Tipo di manuale:
Manuale d'uso
Pagine:
16
Dimensione:
591.48 Kbytes (605672 Bytes)
Lingua:
english
Revisione:
ID del manuale:
071-0437-00
Data:
Qualità:
Documento elettronico, senza ricerca, molto ben leggibile.
Data caricamento:
2017 12 27
MD5:
84812cc85e6a554a20ec7e8b87ad1a89
Scaricamenti:
888

Informazioni

Quick Reference Manual

mostra più dettagli

Manuale d'uso
Tipo di manuale:
Manuale d'uso
Pagine:
268
Dimensione:
2.41 Mbytes (2527618 Bytes)
Lingua:
english
Revisione:
ID del manuale:
071-0433-02
Data:
Qualità:
Documento elettronico, senza ricerca, molto ben leggibile.
Data caricamento:
2017 12 27
MD5:
a8669658186f084efc0ee7c3ffb7390f
Scaricamenti:
1173

Informazioni

This manual supports two very similar instruments: - The CSA8000 Communications Signal Analyzer. - The TDS8000 Digital Sampling Oscilloscope. Differences between the two instruments will be called out when necessary; otherwise, the material applies to both instruments. The word “instrument” refers to either product. This is the user manual for the instrument. It covers the following information: Describes the capabilities of the instrument, how to install it and reinstall its Software Explains how to operate the instrument: how to control acquisition of, processing of, and input/output of information Lists the specifications and Accessories of the instrument This manual is composed of the following chapters: Getting Started shows you how to configure and install your instrument and provides an incoming inspection procedure. Operating Basics uses maps to describe the various interfaces for controlling the instrument, including the front panel and the Software user Interface. These maps provide overviews of the product and its functions from several viewpoints. Reference comprises an encyclopedia of topics (see Overview on page 3–1) that describe the instrument Interface and features, and that give background and basic information on how to use them. (The online help onboard the instrument application describes the Interface, features, and their usage in more detail; detailed descriptions of all programming commands are found in the CSA8000 & TDS8000 Programmer Online Guide manual.) Appendices provides additional information including the specifications and automatic measurement definitions.

mostra più dettagli