AOR Ltd. AR8000 Amplificatore
Produttore:
Modello:
AR8000
Data:
1994
Categoria:
Gruppo:
Descrizione:
World Band Wide Band all mode receiver

Informazioni

General At first glance the AR8000 in it’s static form may look no different to any modern hand-held wide range Receiver, but the similarity ends there... just as soon as the Receiver is switched on!! Initially you are greeted with the opening welcome message on the AR8000 multi-function liquid crystal display “WELCOME TO THE WORLD OF AR8000 RECEIVER”, in a similar way tosign on message displayed by your personal computer. This new experience immediately demonstrates that the AR8000 is no ordinary Radio but THE NEW CONCEPT in Radio design. Internal construction is of a high quality modular surface mount design with the only wires being those connecting to the internal loudspeaker. This ensures the highest performance and reliability. Frequency coverage and modes The AR8000 is a highly sensitive hand-held Receiver boasting the widest frequency coverage of 500kHz to 1900MHz without gaps in the range (actual acceptable frequency input from 100kHz). Step size is programmable in multiples of 50Hz for smooth tuning. The all-mode reception provides AM, USB, LSB, CW, NFM and WFM. Step offset is a useful facility for correctly tuning through bands with unusual offsets and channel spacing. As you might expect from a Radio Receiver of this calibre, an independent 4.0 kHz SSB filter is fitted as standard and the USB/LSB/CW modes use true carrier re-insertion with non-offset frequency readout. Auto-Mode tuning Comprehensive band plan information specific to the target market area has been programmed into the AR8000 Receiver. This inclusion will greatly simplify frequency entry and search programming. The Receiver will “automatically” select the appropriate mode and channels step. Of course, should you wish then both the mode and channel step may be manually changed when required. Custom ferrite bar aerial A custom manufactured ferrite bar aerial has been neatly installed into the AR8000 cabinet to provide a suitable aerial for medium wave reception. 2VFO Twin VFO frequencies (A & B) may be displayed on the LCD simultaneously, one providing a stand-by frequency available for quick transfer (similar to commercial aviation built-in Radio transceivers). The two VFO systems operate independently of each other and store frequency, mode, channel step, step offset and attenuator status. Alphanumeric Display Each memory channel and search bank can be given a specific title using alphanumeric comments up to seven characters in length. The addition of com- ments which may be entered via the keypad/rotary encoder or through the computer port greatly eases the identification of Radio channels or stations. The dot matrix display provides additional information such as frequency readout, S-meter and band scope. When entering data into the Receiver (such as frequency), the AR8000 display provides helpful text prompts to ease operation. Band Scope In VFO mode the AR8000 can check adjacent channels for activity (five channels each side of the centre frequency). The information is displayed by means of vertical bars (like a graph) on the LCD and is updated every five seconds or when the DIAL is turned.

mostra più dettagli

Manuale d'uso
Tipo di manuale:
Manuale d'uso
Pagine:
115
Dimensione:
490.60 Kbytes (502379 Bytes)
Lingua:
english
Revisione:
ID del manuale:
Data:
1994 01 01
Qualità:
Documento elettronico, senza ricerca, molto ben leggibile.
Data caricamento:
2017 10 01
MD5:
4f6e019c8e2fd34409372f44de77a6d1
Scaricamenti:
652

Informazioni

Introduction and accessories ... Accessories supplied ... Table of contents ... Major features ... Precautions ... Location ... Looking after your Receiver ... Power requirements ... NiCads and charging ... Aerial (antenna) connection summary ... Controls and functions ... TOP PANEL ... Aerial (antenna) input ... Earphone connection ... [DIAL] - tuning control / selector ... Squelch control ... Power On/Off & volume control ... FRONT PANEL ... Liquid Crystal Display LCD ... Keypad (extensive information) ... Internal loudspeaker ... LEFT HAND SIDE ... [FUNC] function key ... [MONI] monitor key ... [LAMP] illumination key ... [K.LOCK] keypad lock key ... RIGHT HAND SIDE ... DC 12V - charging and DC input socket ... REAR CABINET ... REMOTE RS232 connector ... Battery compartment ... Basic manual operation of the Receiver ... Before starting ... Switching on ... Configuration NEWUSER/EXPERT status ... Entering frequencies (using keypad) & A=B ... Correcting frequency readout during input ... Correcting incorrect frequencies after input ... Changing a frequency using the UP/DOWN keys .. Changing frequency using the [DIAL] ... Changing frequency step (AUTO) ... Step offset ... Changing Receiver mode (AUTO) ... Attenuator ... Band scope ... Memory banks & channels ... Storing receive data into memory ... Memory recall ... Transfer of memory channels to VFO ... Editing, copying & moving memories ... Memory over-write ... SET EDIT-CH, copying, moving & editing ... Memory copy mode ... Memory copy alternative method ... Memory move mode ... Memory swap mode ... Memory change mode ... Deleting memory channels & banks ... Deleting individual memory channels ... Deleting complete memory banks ... PASSWORD protection of banks ... When the password is first used ... Password access to banks ... Disabling password protection ... If you forget your password ... SCANNING ... Outline introduction to scanning ... Outline of EXPERT facilities ... Scanning considerations ... Scanning a memory bank ... Scanning a single memory bank ... Memory bank linking ... Specifying memory bank linking ... Scanning unlinked banks ... Scan channel PASS (lockout) ... Memory PASS while scanning ... Memory PASS using memory recall ... EXPERT scan options ... SELECT SCAN ... Select scan while in scan mode ... Select scan while in memory recall ... Select scan using the menu ... Select scan "new" channels using the menu ... Deleting individual select scan channels ... Deleting all select scan channels ... Start, pause and cancel select scan ... Priority operation ... Engaging priority operation ... Changing priority channel parameters ... SEARCH ... 76 Manual search ... 77 Program bank search ... 80 Program search - saving active frequencies ... 81 Programming search banks ... 82 Search facilities ... 85 Search, outline of EXPERT facilities ... 85 Linking search banks ... 85 Searching unlinked banks ... 87 EXPERT search operations ... 87 Deleting program search banks ... 90 Frequency PASS (lockout) ... 91 Frequency pass during program search ... 91 Frequency pass menu ... 92 Deleting a pass frequency ... 92 Editing a pass frequency ... 93 Manually entering a pass frequency ... 93 Entering pass frequencies during manual search .. 93 Deleting all pass frequencies from a bank ... 94 Auto store ... 95 Auto store in newuser status ... 95 Auto store in expert status ... 97 Power save ... 97 Changing power save parameters ... 97 Special functions ... 99 Lock detect ... 99 Squelch detect ... 99 Audio wait ... 99 Audio level ... 100 Level wait ... 100 Remote control RS232 ... 100 Setting RS232 parameters ... 101 Changing data input to keypad ... 101 Clone (copy) data between two AR8000 ... 102 Clone (copy) in newuser status ... 102 Clone (copy) in expert status ... 102 Trouble shooting ... 103 Microprocessor reset ... 103 Other possible apparent operating problems ... 104 Other LCD indications & error messages ... 105 Optional accessories ... 106 Aerials (antennas) & earth systems ... 107 Propagation - short wave bands ... 112 Specification ... 115

mostra più dettagli