Telecommunications Techniques Corporation 43440 Interfaccia
Produttore:
Nessuna immagine disponibile!
Forse puoi caricare una foto per la
Telecommunications Techniques Corporation 43440?
Se avete altri manuali per la
Telecommunications Techniques Corporation 43440 potete caricare i file qui .
Modello:
43440
Data:
1997
Categoria:
Gruppo:
Descrizione:
DS1/DS3 ATM INTERFACE
Informazioni
The DS1/DS3 ATM Interface Module enables the FIREBERD 6000
Communications Analyzer to test ATM circuits and equipment
operating at the DS1 rate of 1.544 MHz as well as the DS3
rate of 44.736 MHz. The module is capable of performing the
following tests:
• DS 1 and DS3 physical layer analysis including line and
framing error detection, alarm indicators, etc.
• TC sub-layer tests include PLCP and HEC based cell
mapping; PLCP alarms, statistics and error insertion; and
HEC generation, checking, and erroring.
• ATM layer tests include transmitting and receiving cells
with a pre-defmed or user-defined payload, measuring cell
round trip delay and traffic shaping conformance per ATM
Forum GCRA requirements, monitoring lost or misinserted
cells, generating/receiving OAM cells, and automatic
scanning of active VPI/VCIs.
• AAL layer tests include automatically recognizing AAL1,
3/4, or 5 activity on a selected VPI/VCI, and acquiring
AAL1, 3/4 or 5 SAR PDU and AAL 3/4 or 5 CS PDU statistics.
Support for IEEE 488.2 control is incorporated into the
FIREBERD 6000 and can be used to control and
monitor DS1/DS3 ATM Interface Module.
Tipo di manuale:
Manuale d'uso
Pagine:
72
Dimensione:
2.69 Mbytes (2820832 Bytes)
Lingua:
english
Revisione:
B
ID del manuale:
50-14440-01
Data:
1997 11 01
Qualità:
Documento scansionato, tutto leggibile.
Data caricamento:
2017 01 09
MD5:
90d1856666956fec3086a480b648b779
Scaricamenti:
386
Informazioni
1 GENERAL INFORMATION
... 1-1
1.1 Manual
Summary ...
1-1
L2 DS1/DS3 ATM Interface Module
Overview ...
1-1
1.3 Interface
Compatibility ...
1-1
1.4
Cables ...
1-2
2 Interface DESCRIPTION
... 2-1
2.1 Introduction
...
2-1
2.2 Physical
Description ... 2-1
2.2.1 DS3 [N/DS3 OUT/CLOCK IN
Connectors ... 2-2
2.2.2 DS1 IN/DS1 OUT
Connectors ... 2-2
2.3 Self-Loop
Operation ... 2-2
2.4 Timing
Sources ... 2-2
3 INSTALLATION AND OPERATION
... 2-1
3.1 Introduction
... 2-1
3.2 Interface
Installation ... 2-1
3.3 FIREBERD 6000 Mainframe Setup
... 2-2
3.4 Interface Setup
... 2-3
3.4.1 ACCESS
Menu ... 2-5
3.4.2 TC
Menu ... 2-8
3.4.3 FORMAT
Menu ... 2-10
3.4.4 TX
Menu ... 2-11
3.4.5 RX
Menu ... 2-25
3.4.6 SCAN
Menu ... 2-32
3.5 FIREBERD 6000 Analysis Results
... 2-33
3.6 Interface Status Indicators
... 2-37
3.7 FIREBERD 6000 Printer
Operation ... 2-37
3.8 Auxiliary Functions
... 2-38
4 Interface SPECIFICATIONS
... 4-1
4.1 Introduction
... 4-1
5 MAINTENANCE AND SERVICE
... 5-1
5.1 Introduction
... 5-1
5.2 Maintenance .
... 5-1
5.2.1 In Case of
Difficulty ... 5-1
5.3 Service .
... 5-1
5.3.1 Warranty Policy
... 5-1
5.3.2 In-Warranty Service
... 5-2
5.3.3 Out-of-Warranty Service
... 5-2
5.3.4 Equipment Return
Instructions ... 5-2
A FACTORY DEFAULT SETTINGS
...
A-1
A. I Introduction
... A-l
B REMOTE CONTROL
COMMANDS ... B-1
B.l Introduction
... B-l
INDEX
INDEX-1