Sanyo CMH 1822 Condizionatore d'aria
Produttore:
Modello:
CMH 1822
Data:
0
Categoria:
Gruppo:
Descrizione:
Split System Air Conditioner
Manuale di servizio
Tipo di manuale:
Manuale di servizio
Pagine:
42
Dimensione:
1.90 Mbytes (1997241 Bytes)
Lingua:
english
Revisione:
ID del manuale:
WM-700717
Data:
Qualità:
Documento scansionato, tutto leggibile.
Data caricamento:
2015 07 20
MD5:
abb8fa5f437f472832bfddfe3a221975
Scaricamenti:
1503

Informazioni

1. SPECIFICATIONS 1-1 Unit Specifications ... 1 (1) Outdoor Unit ... 1 (2) Applicable Indoor Unit ... 2 1-2 Major Component Specifications ... 3 (1) Outdoor Unit ... 3 (2) Indoor Unit ... 4 1-3 Other Component Specifications ... 5 (1) Outdoor Unit ... 5 (2) Indoor Unit ... 5 2. PERFORMANCE CHARTS 2-1 Cooling Characteristics ... 6 (1) Operating Current ... 6 (2) Operating Pressure ... 7 2-2 Heating Characteristics ... 8 (1) Operating Current ... 8 (2) Operating Pressure ... 9 3. AIR THROW DISTANCE CHART ... 10 4. FUNCTION 4-1 Room Temperature Control ... 11 4-2 Energy Saver Modes Timing Charts ... 13 4-3 Night Setback Modes Timing Charts ... 14 4-4 Freeze Prevention ... 15 4-5 Overload Prevention ... 15 4-6 Cold Draft Prevention ... 16 4-7 Defrosting Mode ... 17 5. ELECTRICAL DATA • Schematic Diagram ... 19 • Electric Wiring Diagram (PCB Ass’y) ... 20 6. TROUBLESHOOTING 6-1 Check before and after troubleshooting ... 23 (1) Check power supply wiring ... 23 (2) Check inter-unit wiring and inter-unit control wiring ... 23 (3) Check power supply ... 23 (4) Check lead wires and connectors in indoor and outdoor units ... ... ... 23 (5) Reference ... 24 (a) Condition of general cooling operation (b) Condition of general heating operation 6-2 Air Conditioner does not operate ... 26 (1) Circuit breaker trips (or fuse blows) ... 26 (a) When circuit breaker is set to ON, it trips in a few moments (b) Circuit breaker trips in several minutes after turning Air Conditioner ON (2) Neither indoor unit nor outdoor unit runs ... 28 (a) Power is not supplied (3) Indoor A (or B) and compressor A (or B) do not run ... 28 (a) Check OPERATION selector switch in remote control unit (b) Check transformer (c) Check fuse on PCB Ass’y in indoor unit 6-3 A particular component of Air Conditioner does not operate ... 30 (1) Only compressor motor A (or B) does not run ... 30 (2) Only indoor fan does not run ... 32 7. CHECKING ELECTRICAL COMPONENTS 7-1 Measurement of Insulation Resistance ... 34 (1) Power Supply Wires ... 34 (2) Indoor Unit ... 34 (3) Outdoor Unit ... 34 (4) Measurement of Insulation Resistance for Electrical Parts ... 34 7-2 Checking Continuity of Fuse on PCB Ass’y ... 35 7-3 Checking Motor Capacitor ... 35 7-4 Appearance of Electrical Parts ... 36 (1) Power Relay ... 36 (2) Heater Relay ... 36

mostra più dettagli