Fluke 192B Metro d'ambito
Produttore:
Nessuna immagine disponibile!
Forse puoi caricare una foto per la
Fluke 192B?
Se avete altri manuali per la
Fluke 192B potete caricare i file qui .
Modello:
192B
Data:
2002
Categoria:
Gruppo:
Descrizione:
Informazioni
The Fluke I92B/196B-C7199B-C ScopeMeter test tools have
three input channels that are electrically floating with
respect to each other, and with respect to the power adapter
input.
Channel A and channel B are Oscilloscope channels with a
60/100/200 MHz bandwidth. The Meter/External Trigger channel
is a combined DMM and external trigger channel with a
limited (10 kHz) bandwidth.
The B versions have a black&white LCD, the C versions have a
color display.
Tipo di manuale:
Servizio e manuale utente
Pagine:
204
Dimensione:
10.04 Mbytes (10525904 Bytes)
Lingua:
english
Revisione:
ID del manuale:
4822 872 05391
Data:
Qualità:
Documento scansionato, tutto leggibile.
Data caricamento:
2016 02 08
MD5:
1a6bb03669d1d1dbdc351f0c38c4405f
Scaricamenti:
4298
Informazioni
1 Safety
Instructions ... 1-1
1.1
Introduction ... 1-3
1.2 Safety
Precautions ... 1-3
1.3 Caution and Warning
Statements ... 1-3
1.4
Symbols ... 1-3
1.5 Impaired
Safety ... 1-4
1.6 General S afety
Information ... 1-4
2
Characteristics ... 2-1
2.1
Introduction ... 2-3
2.2 Dual Input
Oscilloscope ... 2-3
2.2.1 Isolated Inputs A and B
(Vertical) ... 2-3
2.2.2
Horizontal ... 2-4
2.2.3 Trigger and
Delay ... 2-4
2.2.4 Automatic Connect&View
Trigger ... 2-5
2.2.5 Edge
Trigger ... 2-5
2.2.6 Isolated External
Trigger ... 2-5
2.2.7 Video
Trigger ... 2-5
2.2.8 Pulse Width
Trigger ... 2-5
2.2.9 Continuous Auto
Set ... 2-6
2.2.10 Automatic C apturing S cope S
creens ... 2-6
2.3 Automatic Scope
Measurements ... 2-6
2.3.1
General ... 2-6
2.3.2 DC Voltage
(VDC) ... 2-6
2.3.3 AC Voltage
(VAC) ... 2-6
2.3.4 AC+DC Voltage (True
RMS) ... 2-7
2.3.5 Amperes
(AMP) ... 2-7
2.3.6
Peak ... 2-8
2.3.7 Frequency
(Hz) ... 2-8
2.3.8 Duty Cycle
(DUTY) ... 2-8
2.3.9 Pulse Width
(PULSE) ... 2-8
2.3.10 Vpwm (C versions
only) ... 2-8
2.3.11
Power ... 2-9
2.3.12
Phase ... 2-9
2.3.13 Temperature
(TEMP) ... 2-9
2.3.14 Decibel
(dB) ... 2-9
2.4
Meter ... 2-10
2.4.1 Meter
Input ... 2-10
2.4.2 Meter
Functions ... 2-10
2.5 DMM Measurements on Meter
Inputs ... 2-10
2.5.1
General ... 2-10
Chapter Title Page
2.5.2 Ohms
(Ω) ... 2-10
2.5.3 Continuity
(CONT) ... 2-10
2.5.4
Diode ... 2-11
2.5.5 Temperature
(TEMP) ... 2-11
2.5.6 DC Voltage
(VDC) ... 2-11
2.5.7 AC Voltage
(VAC) ... 2-11
2.5.8 AC+DC Voltage (True
RMS) ... 2-11
2.5.9 Amperes
(AMP) ... , ... 2-12
2.6
Recorder ... 2-12
2.6.1 TrendPlot (Meter or
Scope) ... 2-12
2.6.2 Scope
Record ... 2-12
2.7 Zoom, Replay and
Cursors ... 2-13
2.7.1
Zoom ... 2-13
2.7.2
Replay ... 2-13
2.7.3 Cursor
Measurements ... 2-13
2.8
Miscellaneous ... 2-13
2.8.1
Display ... 2-13
2.8.2 Δ
Power ... 2-13
2.8.3 Probe
Calibration ... 2-14
2.8.4
Memory ... 2-14
2.8.5
Mechanical ... , ... 2-14
2.8.6 Optical Interface
Port ... 2-14
2.9
Environmental ... 2-14
2.10 /ί
Safety ... 2-15
2.11 10:1 Probe
VPS200 ... 2-17
2.11.1
Safety ... 2-17
2.11.2 Electrical
specifications ... 2-17
2.11.3
Environmental ... 2-17
2.12 Electromagnetic
Immunity ... 2-1.8
3 Circuit
Description,, ... ,.,» ... , ... , ... , ... , ... 3-1
3.1
Introduction ... 3-3
3.2 Block
Diagram ... 3-3
3.3 Start-up Sequence, Operating
Modes ... 3-7
3.4 Detailed Circuit
Descriptions ... 3-9
3.4.1 Scope Channel A - Scope Channel
B ... 3-9
3.4.2 Meter/Ext Trigger
Channel ... 3-12
3.4.3 Sampling&Triggering
(S-ASIC) ... 3-15
3.4.4 S-ASIC
supply ... 3-19
3.4.5
ADC’s ... 3-19
3.4.6 Digital
Control ... > ... 3-20
3.4.7 LCD
Control ... 3-22
3.4.8
Power ... 3-23
3.4.9 Slow ADC, RS232 Serial Interface, LCD
Backlight ... 3-28
4 Performance
Verification ...
4-1
4.1
Introduction ... 4-3
4.2 Equipment Required For
Verification ... 4-3
4.3 General
Instructions ... 4-3
4.4 Operating
Instructions ... 4-4
4.4.1 Resetting the test
tool ... 4-4
4.4.2 Navigating through
menu’s ... 4-4
4.4.3 Creating Test Tool
Setup! ... 4-5
4.5 Display and Backlight
Test ... 4-5
4.6 Scope Input A&B
Tests ...
4-7
4.6.1 Input A&B Vertical Accuracy
Test ... 4-7
4.6.2 Input A&B DC Voltage Accuracy
Test ... 4-9
4.6.3 Input A&B AC Voltage Accuracy Test
(LF) ... 4-11
4.6.4 Input A&B AC Coupled Lower Frequency
Test ... 4-12
4.6.5 Input A and B Peak Measurements
Test ... 4-13
4.6.6 Input A&B Frequency Measurement Accuracy
Test ... 4-14
4.6.7 Input A&B Phase Measurements
Test ... 4-15
4.6.8 Time Base
Test ...
4-16
4.6.9 Input A Trigger Sensitivity
Test ...
4-18
4.6.10 Input A AC Voltage Accuracy (HF) & Bandwidth
Test ... 4-19
4.6.11 Input B Trigger Sensitivity
Test ...
4-20
4.6.12 Input B AC Voltage Accuracy (HF) & Bandwidth
Test ... 4-21
4.6.13 Video test using the Video Pattern
Generator ... 4-22
4.6.14 Video test using SC600 Scope Calibration Option
... 4-25
4.7 External Trigger Level
Test ...
4-27
4.8 Meter (DMM)
Tests ...
4-28
4.8.1 Meter DC Voltage Accuracy
Test ...
4-28
4.8.2 Meter AC Voltage Accuracy & Frequency Response
Test ... 4-29
4.8.3 Continuity Function
Test ...
4-30
4.8.4 Diode Test Function
Test ...
4-30
4.8.5 Ohms Measurements
Test ...
4-30
4.9 Probe Calibration Generator
Test ...
4-32
5 Calibration
Adjustment ...
5-1
5.1
General ...
5-3
5.1.1
Introduction ...
5-3
5.1.2 Calibration number and
date ...
5-3
5.1.3 General
Instructions ...
5-3
5.1.4 Equipment Required For
Calibration ...
5-4
5.2 Calibration Procedure
Steps ...
5-4
5.3 Starting the
Calibration ...
5-4
5.4 Contrast Calibration
Adjustment ...
5-6
5.5 Warming Up &
Pre-Calibration ...
5-7
5.6 Final
Calibration ...
5-8
5.6.1 Input A LF-HF
Gain ...
5-8
5.6.2 Input B LF-HF
Gain ...
5-9
5.6.3 input A&B LF-HF
Gain ...
5-11
5.6.4 Input A&B
Position ...
5-12
5.6.5 Input A&B Volt
Gain ...
5-13
5.6.6 DMM Volt
Gain ...
5-14
5.6.7 Input A& B, and DMM
Zero ...
5-15
5.6.8 DMM Ohm
Gain ...
5-16
5.6.9 Calculate
Gain ...
5-17
5.7 Save Calibration Data and
Exit ...
5-17
5.8 Probe
Calibration ...
5-19
6 Disassembling the Test
Tool ...
6-1
6.1.
Introduction ...
6-3
6.2. Disassembly & Reassembly
Procedures ...
6-3
6.2.1 Required
Tools ...
6-3
6.2.2 Removing the Tilt Stand & Hang
Strap ... 6-3
6.2.3 Replacing the Side-Strap, Changing the Side-Strap
Position ... 6-3
6.2.4 Opening the Test Tool, Removing the
Battery ... 6-3
6.2.5 Removing the Main PCA Unit and the
Fan ... 6-5
6.2.6 Removing the Display
Assembly ... 6-6
6.2.7 Replacing the LCD
Window/Decaf ... 6-7
6.2.8 Removing the Keypad and Keypad
Foil ... 6-7
6.2.9 Disassembling the Main PCA
Unit ... 6-7
6.2.10 Reassembling the Main PCA
Unit ... 6-8
6.2.11 Reassembling the Test
Tool ... 6-9
7 Corrective
Maintenance ... 7-1
7.1
Introduction ... 7-3
7.2 Starting Fault
Finding ... 7-4
7.3 Charger
Circuit ... 7-5
7.4 Starting with a Dead Test
Tool ... 7-7
7.4.1 Test Tool Completely
Dead ... 7-7
7.4.2 Test Tool Software Does not
Run ... 7-8
7.4.3 Software Runs, Test Tool not
Operative ... 7-8
7.5 Miscellaneous
Functions ... 7-8
7.5.1 Display and Back
Light ... 7-8
7.5.2 Fly Back
Converter ... 7-10
7.5.3 Slow ADC,
+3V3SADC ... 7-11
7.5.4
Keyboard ... 7-12
7.5.5 Optical Port (Serial RS232
Interface) ... 7-13
7.5.6 Channel A, Channel B
Measurements ... 7-13
7.5.7 Meter Channel (Ext Trigger, Probe
Cal) ... 7-15
7.5.8 Input Signal
Acquisition ... 7-17
7.5.9
ADC’s ... , ... 7-19
7.5.10 Digital Control &
Memory ... 7-20
7.5.11 Buzzer
Circuit ... 7-20
7.5.12 RAM
Test ... 7-21
7.5.13 Power
ON/OFF ... 7-22
7.5.14
Battery ... 7-22
7.6 Loading
Software ... 7-23
8 List of Replaceable
Parts ... 8-1
8.1
Introduction ... 8-3
8.2 How to Obtain
Parts ... 8-3
8.3 Service
Centers ... 8-3
8.4 Final Assembly
Parts ... 8-4
8.5 Main PCA Unit Parts
... 8-6
8.6 Main PCA
Parts ... 8-8
8.7
Accessories ... 8-30
9 Circuit Diagrams
... 9-1
9.1
Introduction ... 9-3
9.2 Tracing signals in circuit
diagrams ... 9-3
9.3 Locating Parts & Test
Points ... 9-3
9.4
Diagrams ... 9-6
10
Modifications ... 10-1
10.1
General ... 10-3
10.2 Software
modifications ... 10-3
10.3 Hardware
modifications ... 10-3
10.4 Main PCA Unit Versions, Software
Versions ... 10-4
Tipo di manuale:
Manuale di servizio
Pagine:
206
Dimensione:
9.71 Mbytes (10177034 Bytes)
Lingua:
english
Revisione:
ID del manuale:
PN 4822 872 05391
Data:
Qualità:
Documento elettronico, senza ricerca, molto ben leggibile.
Data caricamento:
2014 11 29
MD5:
951de7682a2c1ae7299f9ca8aa14f216
Scaricamenti:
4218
Informazioni
1 Safety Instructions
...
1-1
1.1
Introduction ...
1-3
1.2 Safety
Precautions ...
1-3
1.3 Caution and Warning
Statements ...
1-3
1.4
Symbols ...
1-3
1.5 Impaired Safety
...
1-4
1.6 General Safety
Information ...
1-4
2 Characteristics
...
2-1
2.1
Introduction ...
2-3
2.2 Dual Input
Oscilloscope ...
2-3
2.2.1 Isolated Inputs A and B
(Vertical) ...
2-3
2.2.2 Horizontal
...
2-4
2.2.3 Trigger and Delay
...
2-4
2.2.4 Automatic Connect&View Trigger
... 2-5
2.2.5 Edge Trigger
...
2-5
2.2.6 Isolated External Trigger
...
2-5
2.2.7 Video
Trigger ...
2-5
2.2.8 Pulse Width
Trigger ...
2-5
2.2.9 Continuous Auto
Set ...
2-6
2.2.10 Automatic Capturing Scope Screens
... 2-6
2.3 Automatic Scope
Measurements ...
2-6
2.3.1
General ...
2-6
2.3.2 DC Voltage
(VDC) ...
2-6
2.3.3 AC Voltage
(VAC) ...
2-6
2.3.4 AC+DC Voltage (True
RMS) ...
2-7
2.3.5 Amperes
(AMP) ...
2-7
2.3.6
Peak ...
2-8
2.3.7 Frequency (Hz)
...
2-8
2.3.8 Duty Cycle (DUTY)
...
2-8
2.3.9 Pulse Width
(PULSE) ...
2-8
2.3.10 Vpwm (C versions
only) ...
2-8
2.3.11 Power
...
2-9
2.3.12 Phase
...
2-9
2.3.13 Temperature (TEMP)
...
2-9
2.3.14 Decibel
(dB) ...
2-9
2.4 Meter
...
2-10
2.4.1 Meter Input
...
2-10
2.4.2 Meter
Functions ...
2-10
2.5 DMM Measurements on Meter
Inputs ...
2-10
2.5.1
General ...
2-10
2.5.2 Ohms (Ω)
...
2-10
2.5.3 Continuity
(CONT) ...
2-10
2.5.4
Diode ...
2-11
2.5.5 Temperature
(TEMP) ...
2-11
2.5.6 DC Voltage
(VDC) ...
2-11
2.5.7 AC Voltage
(VAC) ...
2-11
2.5.8 AC+DC Voltage (True
RMS) ...
2-11
2.5.9 Amperes
(AMP) ...
2-12
2.6 Recorder
...
2-12
2.6.1 TrendPlot (Meter or
Scope) ...
2-12
2.6.2 Scope Record
...
2-12
2.7 Zoom, Replay and
Cursors ...
2-13
2.7.1
Zoom ...
2-13
2.7.2 Replay
...
2-13
2.7.3 Cursor Measurements
...
2-13
2.8
Miscellaneous ...
2-13
2.8.1
Display ...
2-13
2.8.2 Power
...
2-13
2.8.3 Probe
Calibration ...
2-14
2.8.4
Memory ...
2-14
2.8.5
Mechanical ...
2-14
2.8.6 Optical Interface
Port ...
2-14
2.9 Environmental
...
2-14
2.10
Safety ...
2-15
2.11 10:1 Probe VPS200
...
2-17
2.11.1 Safety
...
2-17
2.11.2 Electrical
specifications ...
2-17
2.11.3
Environmental ...
2-17
2.12 Electromagnetic
Immunity ...
2-18
3 Circuit Description
...
3-1
3.1
Introduction ...
3-3
3.2 Block Diagram
...
3-3
3.3 Start-up Sequence, Operating
Modes ...
3-7
3.4 Detailed Circuit
Descriptions ...
3-9
3.4.1 Scope Channel A - Scope Channel B
... 3-9
3.4.2 Meter/Ext Trigger
Channel ...
3-12
3.4.3 Sampling&Triggering
(S-ASIC) ...
3-15
3.4.4 S-ASIC supply
...
3-19
3.4.5 ADC’s
...
3-19
3.4.6 Digital Control
...
3-20
3.4.7 LCD Control
...
3-22
3.4.8 Power
...
3-23
3.4.9 Slow ADC, RS232 Serial Interface, LCD
Backlight ... 3-28
4 Performance
Verification ...
4-1
4.1
Introduction ...
4-3
4.2 Equipment Required For Verification
... 4-3
4.3 General Instructions
...
4-3
4.4 Operating
Instructions ...
4-4
4.4.1 Resetting the test tool
...
4-4
4.4.2 Navigating through
menu’s ...
4-4
4.4.3 Creating Test Tool
Setup1 ...
4-5
4.5 Display and Backlight Test
...
4-5
4.6 Scope Input A&B Tests
...
4-7
4.6.1 Input A&B Vertical Accuracy Test
... 4-7
4.6.2 Input A&B DC Voltage Accuracy
Test ... 4-9
4.6.3 Input A&B AC Voltage Accuracy Test
(LF) ... 4-11
4.6.4 Input A & B AC Coupled Lower Frequency Test
... 4-12
4.6.5 Input A and B Peak Measurements
Test ... 4-13
4.6.6 Input A&B Frequency Measurement Accuracy Test
... 4-14
4.6.7 Input A&B Phase Measurements
Test ... 4-15
4.6.8 Time Base Test
...
4-16
4.6.9 Input A Trigger Sensitivity Test
... 4-18
4.6.10 Input A AC Voltage Accuracy (HF) & Bandwidth Test
... 4-19
4.6.11 Input B Trigger Sensitivity Test
... 4-20
4.6.12 Input B AC Voltage Accuracy (HF) & Bandwidth Test
... 4-21
4.6.13 Video test using the Video Pattern Generator
... 4-22
4.6.14 Video test using SC600 Scope Calibration Option
... 4-25
4.7 External Trigger Level Test
...
4-27
4.8 Meter (DMM)
Tests ...
4-28
4.8.1 Meter DC Voltage Accuracy Test
... 4-28
4.8.2 Meter AC Voltage Accuracy & Frequency Response Test
... 4-29
4.8.3 Continuity Function Test
...
4-30
4.8.4 Diode Test Function Test
...
4-30
4.8.5 Ohms Measurements
Test ...
4-30
4.9 Probe Calibration Generator Test
...
4-32
5 Calibration Adjustment
...
5-1
5.1 General
...
5-3
5.1.1
Introduction ...
5-3
5.1.2 Calibration number and
date ...
5-3
5.1.3 General
Instructions ...
5-3
5.1.4 Equipment Required For Calibration
... 5-4
5.2 Calibration Procedure
Steps ...
5-4
5.3 Starting the Calibration
...
5-4
5.4 Contrast Calibration Adjustment
...
5-6
5.5 Warming Up & Pre-Calibration
...
5-7
5.6 Final Calibration
...
5-8
5.6.1 Input A LF-HF Gain
...
5-8
5.6.2 Input B LF-HF
Gain ...
5-9
5.6.3 Input A&B LF-HF
Gain ...
5-11
5.6.4 Input A&B Position
...
5-12
5.6.5 Input A&B Volt Gain
...
5-13
5.6.6 DMM Volt Gain
...
5-14
5.6.7 Input A& B, and DMM Zero
...
5-15
5.6.8 DMM Ohm
Gain ...
5-16
5.6.9 Calculate
Gain ...
5-17
5.7 Save Calibration Data and
Exit ...
5-17
5.8 Probe Calibration
...
5-19
6 Disassembling the Test Tool
... 6-1
6.1.
Introduction ...
6-3
6.2. Disassembly & Reassembly Procedures
... 6-3
6.2.1 Required Tools
...
6-3
6.2.2 Removing the Tilt Stand & Hang
Strap ... 6-3
6.2.3 Replacing the Side-Strap, Changing the Side-Strap
Position ... 6-3
6.2.4 Opening the Test Tool, Removing the
Battery ... 6-3
6.2.5 Removing the Main PCA Unit and the
Fan ... 6-5
6.2.6 Removing the Display
Assembly ...
6-6
6.2.7 Replacing the LCD Window/Decal
... 6-7
6.2.8 Removing the Keypad and Keypad
Foil ... 6-7
6.2.9 Disassembling the Main PCA
Unit ... 6-7
6.2.10 Reassembling the Main PCA
Unit ... 6-8
6.2.11 Reassembling the Test
Tool ...
6-9
7 Corrective
Maintenance ...
7-1
7.1
Introduction ...
7-3
7.2 Starting Fault Finding.
...
7-4
7.3 Charger
Circuit ...
7-5
7.4 Starting with a Dead Test Tool
...
7-7
7.4.1 Test Tool Completely
Dead ...
7-7
7.4.2 Test Tool Software Does not Run.
... 7-8
7.4.3 Software Runs, Test Tool not Operative
... 7-8
7.5 Miscellaneous
Functions ...
7-8
7.5.1 Display and Back Light
...
7-8
7.5.2 Fly Back
Converter ...
7-10
7.5.3 Slow ADC,
+3V3SADC ...
7-11
7.5.4
Keyboard ...
7-12
7.5.5 Optical Port (Serial RS232
Interface) ...
7-13
7.5.6 Channel A, Channel B
Measurements ... 7-13
7.5.7 Meter Channel (Ext Trigger, Probe Cal)
... 7-15
7.5.8 Input Signal Acquisition
...
7-17
7.5.9 ADC’s
...
7-19
7.5.10 Digital Control & Memory
...
7-20
7.5.11 Buzzer Circuit
...
7-20
7.5.12 RAM Test
...
7-21
7.5.13 Power
ON/OFF ...
7-22
7.5.14
Battery ...
7-22
7.6 Loading Software
...
7-23
8 List of Replaceable
Parts ...
8-1
8.1
Introduction ...
8-3
8.2 How to Obtain
Parts ...
8-3
8.3 Service Centers
...
8-3
8.4 Final Assembly
Parts ...
8-4
8.5 Main PCA Unit Parts
...
8-6
8.6 Main PCA Parts
...
8-8
8.7
Accessories ...
8-30
9 Circuit Diagrams
...
9-1
9.1
Introduction ...
9-3
9.2 Tracing signals in circuit diagrams
... 9-3
9.3 Locating Parts & Test Points
...
9-3
9.4 Diagrams
...
9-6
10
Modifications ...
10-1
10.1 General
...
10-3
10.2 Software modifications
...
10-3
10.3 Hardware
modifications ...
10-3
10.4 Main PCA Unit Versions, Software Versions.
... 10-4
Tipo di manuale:
Manuale di servizio
Pagine:
86
Dimensione:
2.16 Mbytes (2265076 Bytes)
Lingua:
english
Revisione:
revised
ID del manuale:
PN 4822 872 05391
Data:
2009 10 02
Qualità:
Documento elettronico, senza ricerca, molto ben leggibile.
Data caricamento:
2017 08 05
MD5:
ec364392c8e1c6d05daeec0fbfc225e6
Scaricamenti:
3925
Informazioni
1
2
3
4
Title
Page
Safety
Instructions ...
1-1
1.1
Introduction ... 1-3
1.2 Safety
Precautions ... 1-3
1.3 Caution and Warning
Statements ... 1-3
1.4 Symbols
... 1-3
1.5 Impaired
Safety ... 1-4
1.6 General Safety
Information ... 1-4
Characteristics
...
2-1
List of Replaceable Parts
...
3-1
3.1
Introduction ... 3-3
3.2 How to Obtain
Parts ... 3-3
3.3 Final Assembly Parts
... 3-4
3.4 Main PCA Unit Parts
... 3-6
3.5 Accessories
... 3-8
Performance Verification
...
4-1
4.1
Introduction ... 4-3
4.2 Equipment Required For Verification
... 4-3
4.3 General Instructions
... 4-3
4.4 Operating
Instructions ... 4-4
4.4.1 Resetting the test tool
... 4-4
4.4.2 Navigating through menu’s
... 4-4
4.4.3 Creating Test Tool
Setup1 ... 4-5
4.5 Display and Backlight
Test ... 4-5
4.6 Scope Input A&B Tests
... 4-7
4.6.1 Input A&B Vertical Accuracy Test
... 4-7
4.6.2 Input A&B DC Voltage Accuracy
Test ... 4-9
4.6.3 Input A&B AC Voltage Accuracy Test (LF)
... 4-11
4.6.4 Input A & B AC Coupled Lower Frequency
Test ... 4-12
4.6.5 Input A and B Peak Measurements
Test ... 4-13
4.6.6 Input A&B Frequency Measurement Accuracy Test
... 4-14
4.6.7 Input A&B Phase Measurements
Test ... 4-15
4.6.8 Time Base Test
... 4-16
4.6.9 Input A Trigger Sensitivity
Test ... 4-17
4.6.10 Input A AC Voltage Accuracy (HF) & Bandwidth Test
... 4-19
4.6.11 Input B Trigger Sensitivity Test
... 4-20
4.6.12 Input B AC Voltage Accuracy (HF) & Bandwidth Test
... 4-21
4.6.13 Video test using the Video Pattern Generator
... 4-22
4.6.14 Video test using SC600 Scope Calibration Option
... 4-24
4.7 External Trigger Level Test
... 4-27
4.8 Meter (DMM)
Tests ... 4-28
4.8.1 Meter DC Voltage Accuracy Test
... 4-28
4.8.2 Meter AC Voltage Accuracy & Frequency Response Test
... 4-29
4.8.3 Continuity Function
Test ... 4-30
4.8.4 Diode Test Function Test
... 4-30
4.8.5 Ohms Measurements
Test ... 4-30
4.9 Probe Calibration Generator Test
... 4-32
5
Calibration Adjustment
...
5-1
5.1
General ... 5-3
5.1.1 Introduction
... 5-3
5.1.2 Calibration number and
date ... 5-3
5.1.3 General
Instructions ... 5-3
5.1.4 Equipment Required For Calibration
... 5-4
5.2 Calibration Procedure
Steps ... 5-4
5.3 Starting the Calibration
... 5-4
5.4 Contrast Calibration Adjustment
... 5-6
5.5 Warming Up &
Pre-Calibration ... 5-7
5.6 Final Calibration
... 5-8
5.6.1 Input A LF-HF Gain
... 5-8
5.6.2 Input B LF-HF Gain
... 5-9
5.6.3 Input A&B LF-HF Gain
... 5-11
5.6.4 Input A&B Position
... 5-12
5.6.5 Input A&B Volt Gain
... 5-13
5.6.6 DMM Volt Gain
... 5-14
5.6.7 Input A& B, and DMM
Zero ... 5-15
5.6.8 DMM Ohm Gain
... 5-16
5.6.9 Calculate
Gain ... 5-17
5.7 Save Calibration Data and
Exit ... 5-17
5.8 Probe Calibration
... 5-19
6
Disassembling the Test
Tool ...
6-1
6.1.
Introduction ... 6-3
6.2. Disassembly & Reassembly Procedures
... 6-3
6.2.1 Required Tools
... 6-3
6.2.2 Removing the Tilt Stand & Hang
Strap ... 6-3
6.2.3 Replacing the Side-Strap, Changing the Side-Strap
Position ... 6-3
6.2.4 Opening the Test Tool, Removing the
Battery ... 6-3
6.2.5 Removing the Main PCA Unit and the
Fan ... 6-5
6.2.6 Removing the Display Assembly
... 6-6
6.2.7 Replacing the LCD Window/Decal
... 6-7
6.2.8 Removing the Keypad and Keypad
Foil ... 6-7
6.2.9 Disassembling the Main PCA
Unit ... 6-7
6.2.10 Reassembling the Main PCA
Unit ... 6-8
6.2.11 Reassembling the Test Tool
... 6-9